background image

WALL

HOLES

FOR SCREW FIXING

Differential temperature
LEDs to turn the
pump ON

Differential temperature
button to turn the pump ON

Pump operation mode
control button

Overheating control button

Anti-freeze control button

Pump OFF indication LED

Overheating protection indication led

Pump operation mode
indicator LED 

Differential temperature
button to turn the pump OFF

Differential temperature LEDs
to turn the pump OFF

Pump ON
indication LED

Anti-freeze protection
indication LED

5. DISPLAY IDENTIFICATION AND CONTROL BUTTONS

ANASOL

7. INSTRUMENT FIXATION MODE

 DIN RAIL

WALL

Wall

DIN rail

Instrument

Spare reinforce screws

 (not included)

7.1 DIN mount fixation

7.2 Screw fixation (wall-mounted)

Screws for fixation

 (not included)

6. WIRING DIAGRAM 

Mere illustrative images 

4.4 - Pump operation mode

Press            and select the pump operation mode, as follows:

OFF - Manual mode. Pump is always OFF
AUT - Automatic mode. Pump activation following the user settings.
ON  - Manual mode. Pump is always ON.

1. DESCRIPTION

ANASOL

 

is a

 

differential thermostat for solar heating that acts through the differential temperature 

between sensor S1 (solar collector) and sensor S2 (pool or boiler). Controller for pumped solar heating 
systems applications with overheating and anti-freeze functions.
It has anti-freeze function(protection of pipes), prevents  water overheating (for pools) also has manual 
control of the circulation pump.

2. APPLICATION

Solar heating system for pool or boiler water.

3. TECHNICAL SPECIFICATIONS 

- Power supply:

 115 or 230 Vac ±15% (50/60 Hz)  

-Control temperature:

 

 

Sensor S1- Metal capsule - Silicone: -50 to 200 °C* / -58 to 392°F**

                                       Sensor S2 - Plastic capsule - PVC: -50 to 105 °C* / -58 to 221°F**  

- Load current:

 16(8) A / 250Vac 1HP                          

- Dimensions (W x H x L):

 77 x 39 x 97mm      

- Differential to turn the pump ON: 

from 1 to 10 ºC* / 2 to 20°F**

- Differential to turn the pump OFF: 

from 1 to 10 ºC* / 2 to 20°F**                      

- Operating temperature: 

0 to 45°C* / 32 to 113°F**

- Operation humidity: 

10 to 90% RH (without condensation)

* Celsius (Cº) ANASOL model

**Fahrenheit (Fº) ANASOL model

4. SETTINGS

4.1 - Adjustment

To set the controller functions the correspondent key should be press and hold for three seconds until 
the led starts to flash. After this first step all functions can be set as desired. The adjustment validation 
only will be effective after the led stop flashing (three seconds after the key idleness).

4.1.1 - Differential to turn the pump ON

Press              to set this function. The led shows the temperature differential to activate the pump.

4.1.2 - Differential to turn the pump OFF

Press            to set this function. The led shows the temperature differential to deactivate the pump. 

Example: 

     

T ON

 = 8°C 

                             

T OFF

 = 2°C

When the difference between sensor 1 and sensor 2 goes higher than 8ºC it will activate the pump. The 
pump will only shutdown when the differential temperature between both sensors reach less than 2ºC 
degrees.

4.2 - Protection against overheating

Allows to adjust the temperature to protect against overheating of the sensors S1 and S2, shutting down 
the  water circulation pump if the temperature reaches the selected values.

-  Protection  against  overheating  in  Sensor  S1: 

The  pump  is  switched  off  to  prevent  the 

superheated water circulates through the pipes and damage them (if PVC pipes are used).

- Protection against overheating in Sensor S2:

 The pump is switched off to

 

keep the thermal 

comfort of reservoir water, mainly used in swimming pools.

The hysteresis of this function has a fixed value of C * 2 / 4 F ** that will reactivate the water pump when 
the temperature decreases to the selected value minus the hysteresis. To disable this function select 

“OFF”

 through 

           

 DIFFERENTIAL 

 

 FOR SOLAR HEATING

THERMOSTAT 

 

4.5 - Signaling

The

 PUMP ON

 led ON indicates that the “

NO

” output is activated

 

(pump ON). 

The 

PUMP OFF

 led ON indicates that the “

NC

” output is activated

 

(pump OFF). 

Flashing 

PUMP ON

 and 

PUMP OFF

 leds indicates the following

:

-Some of the temperature sensors are disconnected

 

-Temperature out of control range

The     

T ON

 and      

T OFF 

leds flashing indicates the following

:

-The             temperature setting is higher than            .

4.3 - Anti-freeze protection

If the temperature in the sensor 1 reaches lower values than set by the user, the water pump will activate 
to prevent water freezing in the pipes.

 

The anti-freeze function has 4ºC  / 8 ºF  as preset value to 

deactivate the water pump when the temperature on sensor 1 goes over the freeze protection value, 
plus the differential to deactivate the pump (hysteresis). To disable this function select 

“OFF”

 through            

When activated by this function the water pump will keep 3 minutes (minimum) activated, regardless of 
the sensor 1 temperature.

*

**

.          

.

1

2

Mere illustrative images 

Ver.02

The LED always shows the configuration of sensor S2. To see the configuration of the sensor S1, 
briefly press the              button, the LED will blink quickly in the corresponding value.

 

Sensor 2 indication 

To adjust the overheating protection in the sensor S2
 press               for 3 seconds (LED blinking slowly).

Sensor 1 indication 

To adjust the overheating protection in the sensor S1
press

 for 10 seconds

 

(Led blinking quickly). 

             

 

Power

supply

Pump

Load

supply

0  

  5 - 6    115V

  5 - 7    230V

 115V   230V

Sensor S1- Metal capsule - Silicone

 

Panels or solar collector

Sensor S2- 

Reservoir/Pool

Plastic capsule - PVC

NEW

ANASOL02-04T

-12219

Reviews: