background image

 

 
 

Art. No. 11324  

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11324 V2.0 R1.0  Manual 

Page 1 of 8 

 

User Guide 

1-Wire Gateway 10 Modbus RTU 

 

 

 

  1-Wire Gateway for autonomous communication between 

PLC and a 1-Wire sensor and actuator network  

  Fast readout of all 1-Wire devices in the  

  1-2 seconds clock  

  Data output via Modbus RTU (RS485) Protocol  

  Processed sensor and actuator data  

  Status of each sensor and actuator can be called up 

  Convenient configuration program 

  No additional drivers necessary 

  Optional data storage in case of interruption of 

communication to the control system / host system 

  Power supply for 1-Wire network 

  Designed for all 1-Wire network sizes 

  DIN rail enclosure for switchboard assembly  

  Wide supply voltage range 

  Management of all ESERA automation and many  

  Standard 1-Wire sensors and actuators 

 
 
 

Introduction 

Before you begin with the installation of the 1-Wire Gateway 10 Modbus and put the device into operation, 
please read these operating instructions carefully until the end, especially the section on safety instructions. 
All settings and configurations of the 1-Wire Gateway are carried out with the ESERA Config Tool 3. You can 
find this software on the ESERA website. Please observe the operating instructions for the  
ESERA Config Tool 3, which can be found within the Config Tool 3 software under the "HELP/SUPPORT" 
tab. 
 

Product description

   

 

  

Standard Modbus RTU Protocol 

You can communicate with your industrial controller, e.g. PLC, via standard Modbus RTU protocol with the 1-
Wire Gateway 10. The addressing is clearly structured, comparable to many other Modbus systems. 
Addresses for system, sensor and actuator data are available. 
We provide an address overview with all available data points via the download area of the article on our 
website and via the ESERA Config Tool 3 configuration software. 
 

Auto-E-Connect® Support 

The ESERA 

Auto-E-Connect®

 1-Wire Plug and Play system will be used for the  

1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors 
and actuators on the 1-Wire bus. It is optimized for industrial applications and 
enables significant added value beyond the sensor and chip data. 
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable 
libraries and outputs fully formatted data. 
The Auto-E-Connect functionality will be available from mid 2020 via 1-Wire Controllers, 1-Wire Gateways and  
1-Wire ECO from ESERA available. 
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in 
the download area for this article in the ESERA Webshop. 

Summary of Contents for auto connect 11324

Page 1: ...are carried out with the ESERA Config Tool 3 You can find this software on the ESERA website Please observe the operating instructions for the ESERA Config Tool 3 which can be found within the Config Tool 3 software under the HELP SUPPORT tab 2 Product description Standard Modbus RTU Protocol You can communicate with your industrial controller e g PLC via standard Modbus RTU protocol with the 1 Wi...

Page 2: ...ndly software ESERA Config Tool 3 free of charge Within the software the complete documentation is always at your fingertips as it is automatically updated via the Internet The software is available via the download area of the article on our website and via the configuration software ESERA Config Tool 3 Please use only the USB interface for configuration System time Real time clock You do not hav...

Page 3: ...isplay LED The module has different display LED s Following the function of the displays 9 Wiring diagram module top side 1 Wire Bus 7 Ground 1 Wire 8 1 Wire Data 9 5V output 11 Reset Button module bottom voltage power supply 9 30VDC 1 Minus supply voltage 2 Plus supply voltage 10 Terminating resistor termination RS485 interface Within the 1 Wire Gateway 10 there is a termination or termination re...

Page 4: ...s enabled on the installed device As of firmware version V1 18_38 there is no need to press the Reset Button of the 1 Wire Controllers 1 Wire Gateways more necessary Recovery function Firmware Update If the update is faulty e g due to a power failure during the update you can use the recovery function To do this hold down the reset button located under hole 11 on the top of the module start the up...

Page 5: ...r guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11324 V2 0 R1 0 Manual Page 5 of 8 13 Connection example 1 Wire Gateway 10 1 Wire Hub III sensors and actuators www esera de ...

Page 6: ...ed for configuration and analysis Special attention has been paid here to good legibility and traceability for people The ESERA text protocol works with GET and SET commands which probably every programmer has already used in his own projects The ESERA text protocol is completely open and documented The current version of the programming manual can be found in the article download area of our webs...

Page 7: ...y voltage and that electrical charges stored in the components inside the device have been discharged beforehand Live cables or wires to which the device component or assembly is connected must always be checked for insulation faults or breakages If a fault is detected in the supply line the device must be taken out of operation immediately until the defective line has been replaced When component...

Page 8: ...the purchaser shall be entitled to conversion or reduction ESERA GmbH accepts no liability for the constant and uninterrupted availability of ESERA GmbH nor for technical or electronic errors in the online offer We are constantly developing our products further and reserve the right to make changes and improvements to any of the products described in this documentation without prior notice If you ...

Reviews: