User Guide 

1-Wire Adapter 1  

for 1-Wire cable Temperature Sensors 

 
 

Performance features 

 

Adapter for 1-Wire cable sensors with RJ12 
connectors 

 

Simple connection via screw terminal 

 

No need to remove the plug from cable sensors 

 

Back-up capacitor for stable operation of DS18S20, 
or DS18B20 sensors 

 
 
 
 
 
 
 
 

Introduction 

Before you start to install the adapter and put it into operation, please read this manual carefully until the end, 
especially the section of the safety instructions. 
 

Product description 

The 1-Wire cable Temperature Sensors (Art. No. 11106 and 11107) and the 1-Wire Adapter 1 form a coordinated 
cabling system.  
The 1-Wire Adapter 1 is designed to connect the 1-Wire cable sensors to the 1-Wire network.  
The adapter is connected to the 1-Wire network via screw terminals and to the temperature sensor via RJ12 
modular jack. It is not necessary to remove the existing connectors of the temperature sensor, as the pin 
assignment of the temperature sensors is matched to the 1-Wire Adapter 1. 
As further system components for the 1-Wire network, we recommend the use of a 1-Wire Hub II as power supply 
and 1-Wire Bus Coupler as connection to the control computer. 
  

Auto-E-Connect® Support 

The ESERA 

Auto-E-Connect®

 1-Wire Plug and Play system will be used for the  

1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors 
and actuators on the 1-Wire Bus. It is optimized for industrial applications and 
enables significant added value beyond the sensor and chip data. 
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable 
libraries and outputs fully formatted data. 
The Auto-E-Connect functionality will be available from mid 2020 via 1-Wire Controllers, 1-Wire Gateways and  
1-Wire ECO from ESERA available. 
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in 
the download area for this article in the ESERA Webshop. 
 
 
 
 

Summary of Contents for Auto-E-Connect 11118

Page 1: ...is connected to the 1 Wire network via screw terminals and to the temperature sensor via RJ12 modular jack It is not necessary to remove the existing connectors of the temperature sensor as the pin assignment of the temperature sensors is matched to the 1 Wire Adapter 1 As further system components for the 1 Wire network we recommend the use of a 1 Wire Hub II as power supply and 1 Wire Bus Couple...

Page 2: ... 7 Assignment Screw terminal 1 Wire network Screw terminals 5V 1 Wire Data and GND are provided for connection to the 1 Wire network The assignment is printed on the printed circuit board 8 Operating conditions The module may only be operated at the voltages and ambient conditions specified for it The device can be operated in any position The device is intended for use in dry and dust free rooms ...

Page 3: ...or operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description it is not possible to repair For time consuming assembly or disassembly of cases charges will be invoiced During instal...

Page 4: ...ed designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA GmbH on these designations logos names and trademarks Moreover from their appearance on ESERA GmbH webpages it cannot be concluded that desig...

Reviews: