background image

Operating manual pond pump „Siena LED“

These  instructions  relate  ONLY  to  this  product  and  contain  important  infor

-

mation for using the product for the first time. Please keep these instructions 

for later reference and should always accompany the product in the event of 

transference to a new user.

1. Introduction

Dear Costumer, 

Thank you for purchasing the solar light. With this solar light you purchased a product 

manufactured according to the current state of technology. 

This product fulfils all requirements of the valid European and nati

-

onal regulations. The conformity was proved. The relevant declara

-

tions and documentation are deposited with the manufacturer. 

To maintain this state and guarantee a safe operation, you as the user will have to 

follow this operating manual!

2. Safety Instructions

  

- In case of damages caused by not 

   

  following this operating manual, the 

 

  warranty rights will expire! We exclude 

 

  liability for any consequential damages!

 

- We exclude liability for property or 

 

  personal damages caused by inappropriate 

 

  handling or not following the safety instructions. 

- In these cases any guarantee rights will expire.

Due to safety and admission reasons (CE) it is not allowed to arbitrarily reconstruct 

and/or change the solar light. 

Therefore, please keep to the operating manual. 

The accident prevention rules of the association of the industrial trade cooperative 

association for electric plants and working material are to be considered in industrial 

environments.

3. Intended use

This submersible pump is designed for pumping water in garden ponds, fountains, 

water dishes, etc.  It can pump water through a hose connection or can be operated 

through attached lifting tubes with water sprinklers. 

A solar module or a power pack with a voltage of 12 to 24 volts can be used as the 

energy source. When used with a solar module, the pump works only if enough solar 

radiation strikes the solar module. 

A battery box (accessory) is delivered along with this pump. When battery is on, an 

LED light (accessory) can be attached to the lifting tube. This gives the fountain a 

decorative lighting. The LED light rings are available in different colours.

The delivery rate of the pump can be adjusted using the regulator on the front side of 

the pump. The water pump has no On/Off switch. As soon as the pump is connected 

to its power supply, it starts pumping water. 

4. Installation and commissioning

1.   Roll out the connecting cable of the pump 

completely. 

2.  Ensure that the cap is firmly in place on 

the socket. 

3.  Place the pump in water (please note 

Point 5 here).

4.  Connect the lifting tubes till they project 

out of the water surface. For this, first 

attach the reducer to the pump.

5. You can now choose from 2 different 

water nozzles.

6.  Alternatively, the pump can also be used 

for pumping water through a hose.  For 

this, you just have to attach a hose to the 

pump’s pipe. 

7.  Now supply power to the water pump 

through a solar module. Use the enclosed 

plug with cable (brown = positive pole, 

blue = negative pole) for this. If you have 

purchased this pump as a complete solar 

power system, then the appropriate plug 

is already attached to the solar module. 

Note: 

The plug has reverse-polarity protection, no force should be used while inser-

ting. The glass of the solar module is fragile. 

Caution! Risk of injury!  A broken module cannot be repaired again and must be 

disposed off in an environmental-friendly way. 

8.   If the pumping capacity is too high, you can reduce the amount of water. Simply 

turn the regulator on the front side of the pump in clockwise direction.  Please do 

not use force while adjusting. The adjustment range is 45°. 

4.1 Operation with LED light ring

The accessories include a LED light ring. This light ring can be easily slipped onto 

the lifting tube. 

Electrical connection is established via the socket on the pump. For this, remove 

the drain plug, insert the light ring plug in the socket and tighten the cap nut firmly.

5. Dry run protection

The pump is equipped as standard with a dry run pro-

tection. Two sensor points are provided on the side of 

the housing for this. The pump works if these points are 

under water. If a point projects out of the water, the pump 

does not work.

6. Care and maintenance 

For optimum performance of the pump, it must be washed occasionally with warm 

water depending on the water contamination. To wash the pump, open the housing 

as follows:

Note: 

Please do not use force while dismantling or assembling the pump. The parts 

are very fragile and can break easily. 

1.  Disconnect the pump’s plug. 

2.   Pull the front cover of the pump forward like a slide gently (Figure 1).  

3.   Turn the front cover of the pump by about 45° clockwise (Figure 1) and carefully 

pull the cover forward (Figure 2).  Watch out for the plastic shaft and the seal while 

doing this.

4.   Carefully drag the impeller out of the pump (if necessary, use pliers).  (Figure 3). 

5.   Now clean all the parts carefully with warm water.  

6.  Then plug the shaft with the impeller carefully into the hole of the pump. Ensure 

that the shaft is fitted firmly.

7.   Now place the cover carefully over the pump. Ensure that the seal is fitted proper-

ly. 

8.   Turn the front cover again by 45 degrees counter-clockwise into the starting posi-

tion. 

9.   Slide the lower part of the pump completely into the pump housing. 

The pump is ready to use again.

7. Malfunction

Pump is not pumping water

- Is the pump completely submerged in water? Dry run protection (Point 5)

- Is the polarity of the supply voltage reversed?  Cable colour brown = plus pole, 

  blue = negative pole

- Is the pump dirty? Cleaning the pump, see Point 6.

8. Technical data

•  Operating voltage: 

12 - 24 V DC

•  Degree of protection: 

IP 68

•  Protection class:  

III   

•  Power consumption:  

Approx. 5 W at 12 VDC - approx. 22 W at 24 VDC

•  Pump lift: 

Max. 0.9 m at 12 VDC - max. 2,8 m at 24 VDC

•  Delivery rate:  

Max. 900 l/h at 12 VDC - max. 1500 l/h at 24 VDC

•  Operating temp. range:    +4 to +40°C

Note:

 The pump is only suitable for pumping water. 

Note:

 Protect the pump from frost! 

During cold winter months, the pump must be taken out of the water and placed/

stored in a warm area. The solar module can spend the winter outdoors. 

!

GB

Sensorpoints

lifting tubes

water nozzle

water nozzle

lifting tubes

Customer support:

  If you have problems or questions regarding this product, simply contact us!  

  Internet: www.esotec.de

  By phone: +49 9605-92206-0

  By e-mail for ordering spare parts: 

ersatzteil@esotec.de

  By e-mail for questions about the product: 

technik@esotec.de

  Product: Manufacturer Item No.: 101758

turn 45°

1

2

3

Drain plug

Light ring 

connection

Reviews: