background image

P

=

Speed

Pressure

Flow Rate

Temperature

Re

v.

-Nr

.: 

IM

 3

24

 E

 V

0.

1-

2020

-02

-24

-FW

816

 

 

 

 

Instruction Manual IM 324 E  

 

Page 1 

Phone:  +49 6021- 45 807 - 0 
Fax: 

+49 6021- 45 807 - 20 

Esters Elektronik GmbH 

Hafenrandstr. 14 · D-63741 Aschaffenburg 

eMail: info@esters.de 

Internet: http://www.esters.de 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

I

NSTRUCTION 

M

ANUAL 

IM

 

324

 

 
Device: 

Flow Computer GDR 1501 

Content: 

Instruction manual 

Rev. No.:  IM 324 E V0.1-2020-02-24-FW816 
 

Summary of Contents for GDR 1501 Series

Page 1: ...l IM 324 E Page 1 Phone 49 6021 45 807 0 Fax 49 6021 45 807 20 Esters Elektronik GmbH Hafenrandstr 14 D 63741 Aschaffenburg eMail info esters de Internet http www esters de INSTRUCTION MANUAL IM 324 E Device Flow Computer GDR 1501 Content Instruction manual Rev No IM 324 E V0 1 2020 02 24 FW816 ...

Page 2: ...e installed Operating the equipment for purposes other than its intended use shall void all warranty claims and product liability Noncompliance with the intended use refers to but is not limited to improper installation start up operation maintenance and neglecting the information provided in this manual The device must be integrated into the lightening protection concept of the plant Please ensur...

Page 3: ..._____________________________________ 6 2 4 Electrical values ______________________________________________________________ 6 2 5 Environmental influences_______________________________________________________ 6 2 6 Display housing weight________________________________________________________ 6 3 Device codes ________________________________________________________________________ 7 4 Operating ...

Page 4: ...7 System status ________________________________________________________________________9 Figure 8 Error screen ________________________________________________________________________10 Figure 9 Main menu PARAMETER SCREEN ______________________________________________________10 Figure 10 Edit mode _________________________________________________________________________12 Figure 11 Terminal alloc...

Page 5: ... minute and the solid state relay passes the defined pulses to a superior PLC system With the ECO and PRO version the normalized flow per hour or minute can be calculated and transferred with the current output The standardization can be calculated according to the standards DIN 1343 DIN 6358 DIN ISO 2533 DIN 102 ISO 1 1975 The required values of pressure and temperature are defined in the ECO ver...

Page 6: ...per impulse freely programmable counter output quantity or limit value or device status K2 Relay NO freely programmable pulse output 0 1 1 oder 10 oder 100 m per impulse freely programmable counter output quantity or limit value or device status ACCURACY 0 05 EW 1 Digit bei 23 C POWER SUPPLY 24 V DC 3 V AMBIENT TEMPERATURE 10 bis 60 C STORAGE TEMPERATURE 20 bis 85 C TEST VOLTAGE 3 kV HUMIDITY CLAS...

Page 7: ...hird party devices with Open Collector Reed relay input frequency up to 1 kH 2 Temperature 4 20 mA 2 wire 100 999 C 12 bit or v 2 Temperature Pt100 3 wire 12 bit v 3 Pressure 4 20 mA 2 Leiter 0 1000 bar 12 bit v Output 1 4 20 mA 0 x Bm h l h Bm min l min only Eco and Pro Nm h NL h Nm min NL min flow rate freely programmable input resistance 500 Ohm Relay K1 NO freely programmable pulse output 0 1 ...

Page 8: ... programmed directly on the device using the capacitive touch keyboard The menu is guided using the buttons 4 2 Display Device start The start up screen appears when the device is started After approx 10 seconds the device automatically switches to the first LIVE screen The GDR 1501 differentiates between two screen types the so called LIVE screen including error messages ERROR screens and the PAR...

Page 9: ...onnected sensors Screens that are not relevant to the operating mode of the device are hidden accordingly The display interval can be set by the user A setting of 0 prevents the automatic switchover1 Navigation 1 Parameter 1207 display time System display time determines the intervals at which the screen changes to the next one If the parameter is set to 0 automatic switching is deactivated Switch...

Page 10: ...g of the LIVE SCREENS is deactivated the appropriate error screen is automatically displayed when an error occurs If the error is gone the system switches back to the last LIVE SCREEN 4 5 Display PARAMETER screen The device is parameterized on the PARAMETER screen Starting from the LIVE screen you can reach the PARAMETER screen by holding down the ENTER key The menu opens with hierarchy level 1 At...

Page 11: ...Tree nodes can be setting values PARAMETERS commands COMMANDS or submenu items Every parameter and every menu tree node have a unique ID code A parameter can be open adjustable or closed locked This is indicated by a symbol open or closed diamond Legend Unique parameter ID or menu node ID Open adjustable parameter Closed locked parameter Command Sub menu Navigation Back one menu level Hold for som...

Page 12: ... want to adjust and confirm with Enter The edit mode appears Navigation After exiting the edit mode with ENTER you return to the previous position in the menu tree When editing a linked parameter the next following parameter of the chain is opened for editing instead e g time year time month time day time minute The chain is interrupted if a parameter is not saved ESC Adjust digits Move cursor Sav...

Page 13: ...0 Time Date 1211 Year 1212 Month 1213 Day 1214 Day of week 1215 Hour 1216 Minute x 1500 Process x 1206 Flow A 1208 Flow B 1510 Temperature Temp 1511 Source 1512 Fixed value C 1513 Min value C 1514 Max value C 1520 Pressure 1521 Source 1522 Fixed value mbar 1523 Min value mbar 1524 Max value mbar 1525 Relative absolut 1526 Hydrostatic pressure 1530 Standard 1531 Ref Temp C 1532 Ref Pressure mbar x ...

Page 14: ...A l h x Table 2 Menu structure and Parameter IDs 6 Device error list CODE GERMAN ENGLISH E01 EEP Hardware EEP hardware E02 Parametersatz Param data E03 Seriennummer Serial number E04 Eingang Überlauf Input overflow E05 Ausgang Überlauf Output overflow E06 Empfangspuffer RX buffer E07 Empfangsdaten RX data E08 Sensorbruch Sensor bereak E09 Stromausgang Bürde Current output load E10 Touch Hardware T...

Page 15: ... Internet http www esters de 7 Connecting diagram and terminal allocation TERMINAL NO TERMINAL NO Platinum wire sensor 1 1 Output mA 32 GND 2 33 HB 300 R000000 HB 300 Ex R000000 Third party device 1 5 GND Temperature T pt100 34 GND 6 Signal 35 U1 7 24 V 36 U2 Power Supply 24 V DC 11 GND Pressure P mA 37 12 24 V 38 GND Relay K2 NO 28 Temperature T mA 39 GND 29 40 Relay K1 NO 30 31 Table 4 Terminal ...

Page 16: ...struction Manual IM 324 E Page 16 Phone 49 6021 45 807 0 Fax 49 6021 45 807 20 Esters Elektronik GmbH Hafenrandstr 14 D 63741 Aschaffenburg eMail info esters de Internet http www esters de 8 Housing Dimensions 8 1 Housing for wall mounting Figure 12 Dimension housing wall mounting ...

Page 17: ...nstruction Manual IM 324 E Page 17 Phone 49 6021 45 807 0 Fax 49 6021 45 807 20 Esters Elektronik GmbH Hafenrandstr 14 D 63741 Aschaffenburg eMail info esters de Internet http www esters de 8 2 Housing with DIN rail mounting option HT Figure 13 Dimension housing DIN rail mounting ...

Reviews: