background image

Euphonix  MADI Converters Manual

MI715

 

Analog/AES

 

to

 

MADI,

 

MO705

 

MADI

 

to

 

Analog/AES

Document

 

Revision

:

 

1.

1

Release

 

Date

:

 

Jan,

 

2009

Part

 

Number

:

 

840

10631

01

Euphonix

 

Inc.

220

 

Portage

 

Ave.

Palo

 

Alto,

 

California

 

94306

Phone:

 

650

855

0400

Fax:

 

650

855

0410

e

mail:

 

info@euphonix.com

Web:

http://www.euphonix.com

Summary of Contents for MADI MI715

Page 1: ...ES to MADI MO705 MADI to Analog AES Document Revision 1 1 Release Date Jan 2009 Part Number 840 10631 01 Euphonix Inc 220 Portage Ave Palo Alto California 94306 Phone 650 855 0400 Fax 650 855 0410 e mail info euphonix com Web http www euphonix com ...

Page 2: ...ce or obligation System 5 S5 Max Air PatchNet eMix EuCon R 1 Audio Deck Studio Hub are trademarks of Euphonix Inc 2002 Euphonix Inc All rights reserved worldwide No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means without written permission from Euphonix Inc ...

Page 3: ...2 Power On Sequence 5 1 3 Safety and Precautions 5 1 3 1 220 230 240 VAC Operation 5 Chapter 2 MI715 and MO705 Converters 7 2 1 Features 7 2 2 Applications 7 2 3 MI715 MO705 Front Panel 8 2 4 MI715 Rear Panel 9 2 5 MO705 Rear Panel 11 2 6 Synchroniztion 12 2 6 1 MI715 12 2 6 2 MO705 12 2 7 Specifications 13 ...

Page 4: ... the input s complete dynamic range Each main AES EBU input is automatically evaluat edforsample rateconversion The incoming sample rate is compared with the internal rate If they are the same no conversion occurs If the rates differ sample rate con version is activated and persists until a new input is applied or the internal sample rate changes The sample rate conversion range is 32 56 kHz In ad...

Page 5: ...AC settings The converters preserve their signal quality using linear power supplies that must be manually switched between 115 and 230 VAC The units are shipped set for 115 VAC Move the red two position switch near the power entry module of the converters to the 230 VAC position down for 220 230 240 VAC operation Each unit uses a 0 630 A fuse for 115 VAC operation To operate at 220 230 or 240 VAC...

Page 6: ...it is the responsibility of the user to select an approved power cord with proper construction material current capacity flexibility and strength characteristics Cooling We strongly recommend providing adequate ventilation to the converters particular ly when installed in a rack The MI715 and MO705 converters in particular should have space left above and below every two units so heat can properly...

Page 7: ...k external sync inputs on both units provide synchronization to digital systems Sample Rate Source and Sample Rate are automatically sensed by both units Supported sample rates include 44 1 48 88 2 and 96 kHz In addition pull up and pull down rates for the standard sample rates as well as custom sample rates are available Ϯ Ϯ Applications In addition to their standard use in a Euphonix digital sys...

Page 8: ...nsed or manually selected If an external source is not detected the MI715 reverts to Internal sync the MO705 mutes its outputs If a manually selected source is not present the Sample Rate Source indicator blinks AES Sample Rate locked to AES Input Word Sample Rate locked to Word Clock Input Internal MI715 only Sample Rate locked to its own internal crystal MADI MO705 only Sample Rate locked to MAD...

Page 9: ...s on XLR connectors Input sen sitivity is set from the front panel AES EBU Digital Input female XLR 8 Stereo AES EBU digital input on XLR connectors Parallel AES EBU Digital Inputs female DB25 Two 8 channel digital connectors function in parallel with XLR digital inputs and should not be used simultaneously AES Sync In female XLR Master clock input for the converter when using AES as Sam ple Rate ...

Page 10: ...Euphonix MADI Converters Operation Manual MI715 MO705 Converters Features 10 MADI Out BNC Outputs the digital audio signal 1 8 Analog inputs 9 24 AES inputs ...

Page 11: ...R 8 Stereo AES EBU digital outputs on one XLR connector Parallel AES EBU Digital Outputs female DB25 Two 8 channel digital connectors function in parallel with XLR digital outputs and the two outputs should not be used simultaneously See Figure 3 5 on page 33 for pinout diagram AES Sync In female XLR Master clock input for the converter when using AES as the Sample Rate Source AES Sync Thru male X...

Page 12: ...its internal clock derived from on board volt age controlled crystal The default internal Sample Rate of the MI715 is 48 kHz This default internal rate can be overridden with the Sample Rate button on the front panel of the MI715 directly below the Sample Rate LEDs to 44 1 48 or 96 kHz Ϯ ϲ 2 MO705 The MO705 detects Sample Rate and Sample Rate Source like the MI715 with the following two difference...

Page 13: ...y 12 to 5 Audio Inputs 8 analog 16 AES 8 AES Pairs Analog Inputs 1 8 Electronically balanced XLR 20 k input impedance Level for 0 dBFS Adjustable between 12 and 26 dBu in 2 dB steps Signal to Noise Ratio 105 dB unweighted THD 0 0005 Frequency Response 1 kHz 4 dBu 0 25 dB 20 Hz 20 kHz 48 kHz 2 5 dB 20 Hz 40 kHz 96 kHz CMRR 50 dB 20 Hz 20 kHz Crosstalk 110 dB 1 kHz 100dB 20 Hz 20 kHz Group Delay 41 ...

Page 14: ...s 1 8 Electronically balanced XLR 200 output impedance Level for 0 dBFS Adjustable between 12 and 26 dBu in 2 dB steps Signal to Noise Ratio 101 dB unweighted THD 0 0003 Frequency Response 1 kHz 4 dBu 0 25 dB 20 Hz 20 kHz 48 kHz 2 5 dB 20 Hz 40 kHz 96 kHz CMRR 50 dB 20 Hz 20 kHz Crosstalk 110 dB 1 kHz 100 dB 20 Hz 20 kHz Group Delay 28 2 Fs 588 s 48 kHz AES Outputs 9 24 AES on XLR transformer isol...

Page 15: ... MO705 Converters Features 15 IM715 MO705 Technical Specifications Power Requirements 110 115 VAC or 220 230 240 VAC 50 or 60 Hz Power Consumption 50 W Temperature of Operation 5 35 C Dimensions Height 3 5 in Width 19 in Depth 18 25 in Weight 17 lb ...

Page 16: ... Manual written by Jay Spears and Eddie Jones Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy ...

Page 17: ... s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third groundingprong Thewiderbladeorthethirdprongareprovidedforyour...

Page 18: ... supply cord shall remain readily operable 19 This unit is provided with a power supply cord set suitable for 120V AC input only for U S A and Canada For other than U S A and Canada a qualified person must provide for use with this unit an appropriate approved power supply cord set which is in compliance with the end use country requirements and has a minimum cross sectional area of 1 0mm2 20 For ...

Reviews: