background image

www.evak-pumps.com

Vol.PMDPC-18091-1.2R2-2IN2OUT

DPC-10

Wa

t

er

P

u

u

m

m

p Digital Pressure Controller

Instal

la

la

tion and Operation Manual

EVAK PUMP TECHNOLOGY CORP.

No. 551, Zhongshan Rd., Qingshui Dist., Taichung City 436, Taiwan.

TEL:

 +886-4-26233556    

Fax:

 +886-4-26235559

11.Warning

!

Assemble tool

Do not poke the port

!

Do not pull the cable

 Wire conductors must not be exposed to avoid any shortage from the conductor end.

!

WARNING

Summary of Contents for DPC-10

Page 1: ... lation and Operation Manual EVAK PUMP TECHNOLOGY CORP No 551 Zhongshan Rd Qingshui Dist Taichung City 436 Taiwan TEL 886 4 26233556 Fax 886 4 26235559 11 Warning Assemble tool Do not poke the port Do not pull the cable Wire conductors must not be exposed to avoid any shortage from the conductor end WARNING ...

Page 2: ...lay Technical Data Button Pressure Unit Relay Capacity 1HP in 110V or 2HP in 230V The digital pressure controller can control pump with higher output through a contactor with control circuit voltage of 110Vac or 230Vac in the other hand the supply voltage to DPC is 110Vac or 230Vac 50 60hz please refer to the wiring diagram for requirement Dry Running Digital Pressure Controller DPC 10 Over Pressu...

Page 3: ...the voltage is over 250V please add transformer by yourself DPC 10 Controller Gray Brown Blue Black AC 230V M1 Coil DPC 10 Controller Gray Brown Blue Black 1 phase PUMP WARNING WARNING WARNING Any connection to the contactor please add a R C capacitor spark eliminator to reduce the possible electromagnetic interference WARNING Beware of any connection to the contactor Please add a R C capacitor sp...

Page 4: ...o the current pressure conditions and the preset data value will not be stored c Choose not to modify the delay time press the SET button and LCD display loAd The above setting value is stored and after 3 seconds will automatically return to the current pressure value 2 3 4 setting 0 01 10 00 5 The status of LED lights 6 Parameter display and settings Item Light Message indication Control loop off...

Page 5: ...ing 2 3 0 600 sec hour Auto Reset Auto Time setting of automatic re start running after warning shutdown Dry running or Over pressure α value Auto shutdown setting after continuous running a Select to modify automatic re start time press the left or right button to adjust the value after finishing the setting press the SET button and go to next parameter setting The time of automatic re start auto...

Page 6: ...e right button and adjust the parameter value from dF n to dF y After finishing the setting press the SET button then all the advanced value settings are returned to default value LCD screen will display for 3 seconds and return to the current pressure conditions b Stay on this screen for 30 seconds the display screen will automatically return to the current pressure conditions and the preset data...

Page 7: ...ss for 6 seconds to Lock Unlock the SET button 1 Max pressure setting high pressure Show code P max b Press once to enter basic setting Press to adjust the value upward Press to adjust the value downward 2 Min Start pressure setting low pressure Show code P min Press once Press to adjust the value upward Press to adjust the value downward Press once ...

Page 8: ...stored Show code loAd c Press for 3 seconds to enter advanced setting Press to adjust the value upward Press to adjust the value downward Press once 3 seconds later 5 After finishing above setting 3 seconds later will return to the current pressure status display automatically Press to set up unit Cycle of working pressure unit kg cm psi bar kg cm Press once ...

Page 9: ...tdown Dry running or Over pressure α value Show code Auto reset Press to adjust the value upward Press to adjust the value downward Press once Press to adjust the value upward Press to adjust the value downward Press once St 0 Pressure controller keeps running and will not automatically shut down St 5 St 1 5 Pressure controller will auto shut down after continuously running 0 5 or 1 5 hours and wi...

Page 10: ... 6 Restore to default value setting or not To restore default value settings show code dF y Press to adjust the value to dF y Press once and restore to default value Show code 7 After finishing above settings LCD screen display loAd or 3 seconds later above setting value is stored and it will automatically return to the current pressure value Not to restore default value settings show code dF n Pr...