background image

UPS EVER 

SPECLINE AVR 700

QUICK REFERENCE GUIDE

 

Note: 

to obtain detailed information, please read the full instruction manual, which 

can be downloaded from our website

 www.ever.eu.

1. IN THE PACKAGING  

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

2. ADDITIONAL REMARKS

MODUŁ BATERYJNY

SPECLINE AVR

>10 cm

>10 cm

>10 cm

>10 cm

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

0 ÷ 40 °C

 battery back-ups are not designed to power medical equipment, 

in particular life support machines!

SPECLINE AVR 

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

UPS unit

 

Mounting template

 

Quick 

reference guide

Warranty card

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

DC fuse 

(UNIVAL 19 mm 40 A)

 

Cable glands x 4

4x

 

2

a) insulated sleeve terminal for 1.0 mm  conductor, 8 mm long

-   

for the power supply and output cord

2

b) 

M4 ring terminal for 1.0 mm  conductor

 

-   

c) 

M4 ring terminal for

 10 mm

conductor

  

  

for connecting a battery module or a car battery.

for connecting the PE IN and PE OUT wires

UPS SPECLINE AVR 700

 

4x

 

a

 

b

 

c

 

2x

 

2x

 

4. 

INSTALLATION OF THE UPS

MODUŁ BATERYJNY

SPECLINE AVR

CONNECTING THE BATTERY MODULES

2

- 1-3 42 Ah battery modules can be connected to the UPS. The connections should be made with 10 mm  section wire.
- Both the module and the UPS are delivered with fuses. The DC fuses should be removed from their sockets for transportation and installation. They 
should only be installed after completing all connection steps.
- A protective earthing connection should be made between the battery module and the UPS, with a yellow-green wire. The ends of the wire should 

2

have M4 ring terminals for 1 mm  wire.

CONNECTING THE CAR BATTERY

- A 12 V lead-acid car battery rated up to 150 Ah may be connected to the PSU.

2

- 10 mm  section wires should be used to make the connection.
- Mistakenly connecting an excessively high voltage or using a power source with wrong polarity may result in the need to return the UPS to the 

  

service department.
- Special attention must be paid to the polarity of connection (the battery's plus connection with the UPS unit's plus connection, the battery's minus 
connection with the UPS unit's minus connection). 

< 150 Ah

3. ELEMENTS OF THE UPS AND BATTERY MODULE  

1. To connect the UPS to the mains, attach the ends of the power cord to the terminals (L, N, PE) of the INPUT connector. The power cord is not included. 
2. To make sure the UPS and the connected devices operate properly, the N (neutral) conductor must be continuous. 

3

. To connect the secured device to the UPS, connect the ends of the individual conductors to the terminals (L, N, PE) of the OUTPUT connector.

4. The power cords of the UPS and the protected device must be secured against unintended and sudden removal by attaching cable glands. The connections 

2

must be made with 1 mm  section wires. The terminals of the wires (L, N) should end with sleeves and the terminal of the PE wire should end with 

2

an M4 ring terminal for 1 mm  wires.
5. The distance between the UPS and the battery modules or the car battery should be as low as possible. This allows to use shorter connection cables, 
which greatly reduces power losses in the cables.

SPECLINE AVR 700 UPS units have no built-in batteries - an external battery module or a lead-acid car battery should be connected to provide back-up 
power supply.

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

max. 1,8 m

230 V

3

4

SPECLINE  AVR

SPECLINE  AVR

STATUS

SPECLINE AVR

1

2

2

1

1 – Connectors chamber
2 – Cable glands 
3 – B
4 – Battery module installation brackets
5 – DC fuse sockets 

attery module earthing point

3

5

2

4

MODUŁ BATERYJNY

SPECLINE AVR

SPECLINE 

A

VR BA

TTER

Y

 MODULE

6

4

7

8

5

1 – 

Main switch

2 – Signaling LED
3 – 

Connectors chamber

4 – 

Cable glands

5 – 

DC fuse socket (battery)

6 – 

AC fuse socket (mains)

7 – 

Installation brackets

8 – 

SPECLINE AVR battery module earthing 

point

POWER CORD

BATTERY MODULE

PE

N L

EN

POWER SOURCE

IN

IN

IN

IN

OUT

OUT

OUT

OUT

LOAD

LOAD

LOAD

LOAD

POWER SOURCE

UPS unit's supply (in) installation

UPS unit's supply (

out

) installation

POWER SOURCE

POWER SOURCE

CORRECT

INCORRECT

UPS

ADDITIONAL BATTERY MODULES

IN

OUT

MAINS

LOAD

UPS

CAR

BATTERY

IN

OUT

MAINS

PE

IN

PE

IN

PE

OUT

PE

OUT

LOAD

12 V DC

BATTERY

12 V DC

BATTERY

Reviews: