background image

 

 

 

 

Speed Dome 

EPTZ3000/EPTZ3000I 

 

 

 

USER MANUAL 

 

 

 

 

 

 

Date: Feb15, 2006 

Summary of Contents for EPTZ3000

Page 1: ...Speed Dome EPTZ3000 EPTZ3000I USER MANUAL Date Feb15 2006 ...

Page 2: ...0 EPTZ3000I INSTALLATION 2 12 2 1 Packing List 2 12 2 2 Cable Needed 2 12 2 3 Initial Setup 2 13 2 3 1 Address Setting 2 14 2 3 2 Communication Protocol Setting 2 17 2 3 3 Transmission Speed Setting Baud Rate Setting 2 17 2 3 4 RS 485 Bus Terminal Resistance 2 18 2 4 Rack and Speed Dome Installation 2 19 2 4 1 Installation Requirements 2 19 2 4 2 EPTZ3000 Dome Camera Wall Mount Installation 2 19 2...

Page 3: ... of the Setup Menu 3 27 3 1 1 Camera Setup Menu 3 28 4 EPTZ3000 3000I FUNCTION SETUP AND OPERATION 4 34 4 1 Manual Control Mode 4 34 4 2 Auto Pan Mode 4 34 4 3 Position Setting 4 34 4 4 Tour Mode 4 35 4 5 Alarm Link to a Position Tour 4 36 4 6 Other operations 4 36 APPENDIX The Alarm I O Connection 4 37 ...

Page 4: ...objects clear in a high illumination background Vertical double density interline CCD with a slower shutter and true Day Night function Electronics flip no mechanical flip is necessary 520 color 570 B W TVL PAL NTSC image formats support Auto and fast focus increases the searching speed and precision Auto Iris adjusts the monitoring image to the best brightness White Balance function makes the sha...

Page 5: ...set and each tour contains up to 16 positions Up to 256 speed domes can be supported on a RS 485 bus when all speed domes are controlled by keyboard EKB500 Auto heater and fan to fit all kinds of temperature outdoor models Built in 4 alarm inputs and 1 alarm output All of the features make the intelligent high speed dome camera works for a wide range and demanding application such as banks airport...

Page 6: ...ting moisture 95 Communication RS 485 Communication speed 1200 2400 4800 9600bps Horizontal rotation speed 0 01 s 360 s 1 239 grade shift gears Horizontal rotation range 360 unlimited rotation Tilt rotation range 180 pendulum motion Auto zoom speed control Control speed auto adjusted according to zoom length changing Auto Pan 2 points scanning Can set freely Auto Pan speed 1 239 grade available Dw...

Page 7: ...unication RS 485 Address editable Yes through DIP switch Speed Dome Address 0 255 Manual Pan tilt speed Pan 0 01º 360º s Tilt 0 01º 360º s Video Output BNC Safety CE FCC Dimension 220 W x 310 H mm Weight 3 2kg ...

Page 8: ... Bolt Hex x3 M3 Bolt x3 BNC Cable Power Cable RS485 Cable Connection Bus Bulb Mechanical Part Camera Module Control board Base PCB board Housing Clip BNC Cable Power Cable RS485 Cable Connection Bus Bulb Mechanical Part Camera Module Control board Base PCB board Ceiling Button EPTZ3000I EPTZ3000 ...

Page 9: ...white text The details of the alarm connector JP5 are shown on the APPENDIX A For EPTZ3000 outdoor model JP1 JP3 and JP6 that are two pin connectors need to be taken off during installing JP1 and JP3 are connectors for heater and they can be switched JP6 is a fan controller connector that turns on off of the fan The 3 cables are too short to be connected to a wrong connector when putting them back...

Page 10: ... with two dipswitches is the control board of EPTZ3000 EPTZ3000I The two switches are used to set address protocol Baud Rate video format and terminal resistance SW1 ON 1 2 3 4 5 6 7 8 CPU ON 1 2 3 4 5 6 7 8 SW2 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 Protocol BAUD ...

Page 11: ...000I Connection Alarm 1 Alarm 4 Alarm 3 Alarm 2 GROUND RS485 Tx RS485 Tx 24V AC 110V AC Video Out POWER 24V AC 3 5 A BNC 1 0Vpp 0 2V 75 RS485 Control Line 4 ALARM INPUTS Adapter Ω EPTZ3000 EPTZ3000I ALARM OUTPUTS N C N O COM ...

Page 12: ... EPTZ3000 EPTZ3000I to a monitor 3 Connect the power to the EPTZ3000 EPTZ3000I and a keyboard EKB500 After the EPTZ3000 EPTZ3000I finishes the self test mode you can start to operate the EPTZ3000 EPTZ3000I via the keyboard To operate the EPTZ3000 EPTZ3000I IRIS Focus F Zoom In N Out UP DOWN LEFT RIGHT ZoomIN ZoomOUT 1 Shift the Joystick up down or right left to view from camera 2 Turn the top of t...

Page 13: ...ical part with a camera module x1 Wall mount bracket x1 Adapter x1 Tool packet Glove x2 M5 Hex Allen wrench x1 Pin connector x1 M5 screw Hex x3 for wall mount bracket fixing M3 screw x3 for bulb fixing 2 2 Cable Needed Power Cable An adapter with 24V AC 3 5A output provides the power to the EPTZ3000 EPTZ3000I An extension power line may be needed Note The input AC voltage range of an adapter depen...

Page 14: ... list A suitable wire that has low signal decline can be used as an alarm cable 2 3 Initial Setup Initial setup includes dome address communication protocol transmission speed video format and terminal resistance settings All of the settings should be confirmed before the dome is installed The control related setting that is address communication protocol and transmission speed have to be set cons...

Page 15: ...ress and there are 256 addresses can be selected 0 255 28 256 It also means that there are up to 256 dome cameras that can cascade on the RS 485 bus The dipswitch setting and the indicated address are represented in the following chart Note The factory default address is 1 Notice Please make sure the power is off before setting and restart the EPTZ3000 EPTZ3000I to enable a new value after changin...

Page 16: ...ess Switch Address Switch Address Switch Address Switch Address Switch Address ON 1 2 3 4 5 6 7 8 Switch Address 65 ON 1 2 3 4 5 6 7 8 66 ON 1 2 3 4 5 6 7 8 67 ON 1 2 3 4 5 6 7 8 68 ON 1 2 3 4 5 6 7 8 69 ON 1 2 3 4 5 6 7 8 70 ON 1 2 3 4 5 6 7 8 71 ON 1 2 3 4 5 6 7 8 72 ON 1 2 3 4 5 6 7 8 73 ON 1 2 3 4 5 6 7 8 74 ON 1 2 3 4 5 6 7 8 75 ON 1 2 3 4 5 6 7 8 76 ON 1 2 3 4 5 6 7 8 Switch Address 77 ON 1 ...

Page 17: ... 191 Switch Address Switch Address Switch Address Switch Address Switch Address Switch Address ON 1 2 3 4 5 6 7 8 Switch Address 193 ON 1 2 3 4 5 6 7 8 194 ON 1 2 3 4 5 6 7 8 195 ON 1 2 3 4 5 6 7 8 196 ON 1 2 3 4 5 6 7 8 197 ON 1 2 3 4 5 6 7 8 198 ON 1 2 3 4 5 6 7 8 199 ON 1 2 3 4 5 6 7 8 200 ON 1 2 3 4 5 6 7 8 201 ON 1 2 3 4 5 6 7 8 202 ON 1 2 3 4 5 6 7 8 203 ON 1 2 3 4 5 6 7 8 204 ON 1 2 3 4 5 6...

Page 18: ...re the power is off before setting and restart the EPTZ3000 EPTZ3000I to enable a new value after changing Set all of protocol switches to ON the speed EPTZ3000 EPTZ3000I will enter a self test mode 2 3 3 Transmission Speed Setting Baud Rate Setting The 4th and 5th bits of the SW2 on the PCB board are used to set the Baud Rate The default baud rate setting is 9600 ON 1 2 3 4 5 6 7 8 SW2 Protocol B...

Page 19: ... enable or disable the terminal resistance When it is switched ON the BUS terminal resistance is connected ON 1 2 3 4 5 6 7 8 SW2 Protocol Baud Rate Terminal Resistance ON 1 2 3 4 5 6 7 8 OFF ON ON 1 2 3 4 5 6 7 8 Keyboard DVR RS 485 Control Unit n 255 Ternimal Resistance ON CAM 0 CAM 1 CAM n Note When the dome is out of control or does not work under control well try to switch the terminal resist...

Page 20: ...cted installation location is suitable for the EPTZ3000 EPTZ3000I 2 4 2 EPTZ3000 Dome Camera Wall Mount Installation Notice Installation location that is a wall a pole or a ceiling needs to support above five times the total weight of the camera assembly about 16 kg to avoid shaken images and dropping 1 Set wall mount bracket on the wall Mark the center of the holes on the wall against the bracket...

Page 21: ...ing on the wall mount bracket and screw in 3 M5 bolts Hex on the top of the bracket with the attached Hex Allen wrench to fix the housing RELAY JP6 JP4 JP3 JP1 JP5 Video Video RS485 RS485 AC24 AC24 M5 Bolt Hex Allen wrench 4 Connect the cable connectors to the nodes on the PCB board and then fix the PCB board in the housing by screwing 4 bolts on it Notice Please notice the polarity of control lin...

Page 22: ...on the base and then connect and fix the connection bus to the PCB board on the mechanical part Notice The camera module on the mechanical part is very sensitive Please be careful when installing this part 6 Remove the lens protection cover before installing the bulb Align the 3 bolt holes into the 3 housing bolt holes and screw three M3 bolts with the attached small screw driver to fix the bulb G...

Page 23: ...tion 1 Take off the housing from the packing and take off the PCB board 4 bolts on it inside the housing 2 Cut the ceiling against the housing s shape with a saw 3 Thread the cable through the screw and the hole on the top of the housing and tighten up the screw to fix the cable 4 Place the housing into the hole that you just made Fix the housing on the ceiling with two clips adjust the screws of ...

Page 24: ...polarity of control line is mis connected 6 Align the two screw holes on the bottom of mechanical part to the two bolts on the base of the housing and twist the mechanical part clockwise a little bit in order to engage it with the base Screw the two bolts on the base and then connect and fix the connection bus to the PCB board on the mechanical part ...

Page 25: ...onnection wire to the housing in order to prevent the bulb from being drop down Align the 2 buttons on the bulb base with the 2 buttons on the housing and push bulb base to clip the housing GLOVE Connection wire Button Button Notice In order to protect the bulb from dirt and scrape please put on the gloves before installing the bulb 8 Turn on the power and start to operate the EPTZ3000I ...

Page 26: ...er The pole mount is used for installing a speed dome on the ceiling indoors or outdoors The extension poles are available for the pole mount 2 5 2 EPTZ PMA Pole Mount Adapter The pole adapter is used for installing a wall mount bracket to a pole indoors or outdoors ...

Page 27: ...2 26 2 5 3 EPTZ CMA Corner Mount Adapter The corner mount are used for installing a wall mount bracket to a 270 corner of walls indoors or outdoors ...

Page 28: ... Joystick up down to change subentries and right left to change the setting CAM ID DZOOM FOCUS IRIS WBC MODE ALM IN1 SET ALM IN2 SET ALM IN3 SET ALM IN PRIO ALM OUT WDR PRIVATE ZONE LOAD DEFAULT EXIT MENU TITLE DISP Option Items OFF ON AUTO MAN OFF ON OFF ON OFF N C N O OFF N C N O 2341 3412 4123 1234 OFF 3 5 10 20 30 60 SEC OFF N C N O AUTO MAN LOW MIDDLE HIGH OFF OFF ON ALM IN4 SET OFF ON SHUTTE...

Page 29: ...pe auto focus manual focus and one push focus are available AUTO Auto focus is enabled MAN Manual focus is enabled ONE PUSH Enable the one push trigger focus mode The focus lens holds the same position until the next trigger command is received This function prevents the wrong focus in dark 4 IRIS Iris type auto iris and manual iris are available AUTO Auto iris is enabled MAN Manual iris is enable...

Page 30: ...formance To adjust a proper value is important 7 TITLE DISP Display the title ON Display the title OFF Disable the title display 8 ALM IN1 SET The status of input alarm 1 N O Enable a normal open alarm input N C Enable a normal close alarm input OFF Disable alarm input 9 ALM IN2 SET The status of input alarm 2 N O Enable a normal open alarm input N C Enable a normal close alarm input OFF Disable a...

Page 31: ...4 1 3412 The alarm priority is 3 4 1 2 4123 The alarm priority is 4 1 2 3 13 ALM OUT Duration time of the alarm output OFF Disable alarm output 3 5 10 20 30 60 SEC 14 WDR Wide Dynamic Range LOW Low wide dynamic range MIDDLE Middle wide dynamic range HIGH High wide dynamic range OFF Disable wide dynamic range 15 SHUTTER ESC Auto electrical shutter A FLK Anti Flicker Camera will auto adjust the shut...

Page 32: ...ual shutter x4 four time default manual shutter x6 six time default manual shutter x8 eight time default manual shutter 16 AGC Auto Gain Control OFF Auto Gain Control Off LOW Low Auto Gain Control MIDDLE Middle Auto Gain Control HIGH High Auto Gain Control Note AGC setting will affect the wide dynamic range or other image performance To adjust a proper value is important 17 PRIVATE ZONE Private zo...

Page 33: ...GRESS Auto regress to the shortest path during set a position It can shorten the response delay and increase the response performance and speed dome lifetime ON Enable the auto regress function OFF Disable the auto regress function 19 X CNT X axis counter This counter counts the x axis movement and 1 is counted when the speed dome pans 360 20 Y CNT Y axis counter This counter counts the y axis mov...

Page 34: ...t setting Press Clr Menu whenever you want to quit menu setting 24 EXIT To exit Select this item and then press Enter to quit setting Press Clr Menu whenever you want to quit menu setting Select this item and then press Enter to quit setting Press Clr Menu whenever you want to quit menu setting ...

Page 35: ...et by pressing Set Home 4 2 Auto Pan Mode Two point auto pan Press A Pan to enter the auto pan mode and then the system will ask you to enter the auto pan speed 1 239 Press Enter to start auto pan In order to set the two points press Set A Pan and then enter the dwell time 1 239 seconds of each point 360 auto pan Press Shift A Pan to enter the 360 auto pan The camera will turn 360 automatically bu...

Page 36: ...ic characteristics are 0 9 A Z and a space Delete a preset position Press Clr Position to delete a preset position The system will ask you to enter the position number that you would like to delete and then press Enter 4 4 Tour Mode In the tour mode you can set a tour for viewing There are 16 tours can be set and 16 preset positions in a tour One way tour Mode Press Tour to enter the tour mode The...

Page 37: ...I have 4 alarm inputs that can be set to link to a position or a tour when an alarm is triggered Set an alarm link Press F1 to set an alarm link Enter the alarm number and then press Enter Switch the Joystick up down to select a position or a tour enter a position or tour number and then press Enter to confirm the alarm link setting Delete an alarm link Press Clr F1 to delete a link of alarm to po...

Page 38: ...re are 4 alarm inputs and 1 alarm output available The alarm I O connector that is marked as JP5 is a nine pin connector It is located on the PCB board of the housing Pin Function 1 Alarm Input 3 2 Ground 3 Alarm Input 2 4 Alarm Input 1 5 Ground 6 Alarm Input 0 7 Normal Open N O 8 Common COM 9 Normal Close N C ...

Page 39: ... 844 8838 www everfocus com European Office Albert Einstein Strasse 1 D 46446 Emmerich Germany TEL 49 2822 9394 0 FAX 49 2822939495 www everfocus de China Office Room 609 Technology Trade Building Shandgdi Information Industry Base Haidian District Beijing China TEL 86 10 62971096 FAX 86 10 62971432 www everfocus com cn Japan Office 1809 WBG MARIBU East 18F 2 6 Nakase Mihama ku Chiba city 261 7118...

Reviews: