- 1 - 

AN180 

Z-Wave On/Off Mini Plug 

 
The On/Off Mini Plug is a Z-Wave

TM

 enabled device which is fully compatible with any Z-Wave

TM

 enabled 

network.    Z-Wave

TM

 enabled devices displaying the Z-Wave

TM

 logo can also be used with it regardless of 

the manufacturer, and ours can also be used in other manufacturer’s Z-Wave

TM

 enabled networks.   

Inclusion of this unit on other manufacturer’s Wireless Controller menu allows remote operation of the unit 
and the connected load. 

 

The On/Off Mini Plug is designed to control the on/off status of lighting and appliances load in your house.   
At 220-240V voltage, this Plug can support up to 1500W resistive, 800W incandescent, 200W motor, or 
200W fluorescent load.

 

 
Product Overview

 

    

 

 

Adding to Z-Wave

TM

 Network 

 
On the unit you can find a link key which is used to carry out the function of inclusion, exclusion, and reset.   
When power is applied for the first time, the LED will flash on and off alternately and repeatedly, implying that 
it has not been assigned a node ID and cannot work with other Z-Wave devices yet.    This unit supports the 
Auto Inclusion function when power is applied and no node ID is stored in the memory. 
 

Auto Inclusion 

 
The module may automatically execute the function of inclusion when... 
1.  The power is applied for the first time and no node ID has been stored in the module. 
2.  The execution of reset is successful where the stored node ID is cleared. 

 
Note:

 The duration for Auto Inclusion is about 4 minutes.    Unlike the “inclusion” procedure shown in the 

table below, the execution of Auto Inclusion is automatic without the necessity of pressing the link key.   

 

Action/Status 

Description 

LED indication 

No node ID 

The Controller does not allocate a node ID to the unit. 

2-second on, 
2-second off 

Auto Inclusion 

The power is applied for the first time and no node ID has 
been stored in the module, or after executing reset. 

 

 
Inclusion 

1.  Put the Z-Wave Controller into inclusion mode. 

 

2.  Press the link key three times within 1.5 seconds to put 

the unit into inclusion mode. 

 
Exclusion 

1.  Put the Z-Wave Controller into exclusion mode. 

 

2.  Press the link key three times within 1.5 seconds to put 

the unit into exclusion mode. 

Reset 
(This procedure 
should only be used 
when the network 
primary controller is 
inoperable.) 

1.  Press the link key three times within 1.5 seconds to put 

the unit into exclusion mode. 

 

2.  Within 1 second of step 1, press link key again and 

hold it until LED is off (about 5 seconds). 

 

3.  Node ID is excluded.    The device reverts to factory 

default state and will be in auto-inclusion mode for 4 
minutes. 

 

 Failed or successful results in including/excluding the node ID can be viewed on the Controller. 

 

Operation 

 
Under normal operation mode, press the on/off button on the unit to control the on/off status of the connected 
load.    When power is on, the LED indicator will turn on for 5 seconds and then turn off (or slow flash if no 
node  ID  is  stored).    The  unit  can  also  be  controlled  by  receiving  command  signals  from  the  Z-Wave 
Controller. 
 
The unit is able to remember the status of the relay when power is cut off (such as power black-out).    When 
power is supplied again, the unit will resume the last status of the relay (on or off) automatically. 
 

Programming 

 

Z-Wave Group Support 

 

The  unit  supports  two  association  groups  with  1  node  support  for  Grouping  1  and  4  nodes  support  for 
Grouping  2.    This  has  the  effect  that  when  the  unit  is  operating,  all  devices  associated  with  the  unit  will 
receive the relevant reports. 
 

  When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1. 

  When setting the unit or changing the unit’s status, the unit will send a Binary Switch Report to the node 

of Group 1. 

  Device Reset: When performing Reset the unit will send Device Reset Locally Notification to the node of 

Group1. 

  The minimum interval time between two reports sent from this unit to the node of Group 1 is 3 seconds.   

Refer to 

Configuration

 parameter 2 for more information. 

  When the button on the unit or the wall switch is pressed, the unit will send a Basic Set command to the 

nodes  of  Group  2.    When  the  unit  is  OFF,  Basic  Set  Value  =  0x00.    When  the  unit  is  ON, Basic Set 
Value = 0xFF. 

 

Z-Wave Plus Info

 

 

Role Type 

Node Type 

Installer Icon 

User Icon 

Slave Always On 

Z-Wave Plus node 

On/Off Power Switch 

On/Off Power Switch 

 

Version 

 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

3.95 ( 6.51.02) 

Firmware 0 Version 

1V1 

Hardware Version 

Firmware 1 Version 

0V4 

On/Off Button   
& Link Key   
(with LED light) 