User Manual 

 

 

 

 

True RMS AC Voltage/Current 

Datalogger 

 

Model DL150 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional User Manual Translations available at www.extech.com 

 

Summary of Contents for DL150

Page 1: ...User Manual True RMS AC Voltage Current Datalogger Model DL150 Additional User Manual Translations available at www extech com ...

Page 2: ... the instrument when your hand is wet Do not input over range during measurements Never open the battery cover during measurements Stop using the instrument when there is any structural defect or exposed metal parts Do not install substitute parts or make modifications on the meter Never replace the battery in moist areas Ensure the meter is disconnected and switch off before opening the battery c...

Page 3: ...ull When there is only a frame icon displayed the battery is exhausted and should be replaced with a new one 2 AC adaptor Jack 3 ON OFF Button 4 MAX MIN Press the button one time to display the MAX maximum reading Press again to display the MIN minimum reading A third press will exit MAX MIN mode The meter will automatically exit MAX MIN mode in 10 seconds if no button is pressed 5 CH Input Jack I...

Page 4: ... REC icon will appear in the display indication that recording has begun 6 Press and Hold the START STOP button for four seconds to stop recording The REC icon will disappear from the display NOTE if you STOP the recording you MUST reprogram the meter with the software before recording again 7 Remove the probe from the test circuit connect the datalogger to a PC and use the supplied software to do...

Page 5: ...be used for 60 days or more remove the battery and store separately Note If the clock does not set to the correct time replace the 3V button battery PC Interface and Software Check the software download page of the website www extech com software downloads for the latest version of the PC software Instructions for use and features are detailed in the supplied software HELP utility ...

Page 6: ...D Low battery indication Empty battery symbol appears on the LCD Power supply 4 AAA Batteries Battery life 5 days approximately AC Adaptor 9V 0 5A Standards CAT III 600V Operating Temperature 32 to 122 F 0 to 50 C Operating Humidity 70 RH Current Clamp Jaw opening 0 5 12 7mm Dimensions 4 5 x 2 5 x 1 3 114 x 63 x 34mm Weight 8 7oz 248g Range Accuracy Voltage 40Hz to 1kHz 10VAC to 600 0VAC 2 0 1V Cu...

Page 7: ...ibration for most of our products Contact us for information on calibration and repair availability refer to the contact information below Annual calibrations should be performed to verify meter performance and accuracy Product specifications are subject to change without notice Please visit our website for the most up to date product information www extech com Contact Customer Support Customer Su...