background image

USER GUIDE 

 

 
 
 

IR Thermal Scanner 

 

Model IRT500 

 

Summary of Contents for IRT500

Page 1: ...USER GUIDE IR Thermal Scanner Model IRT500 ...

Page 2: ... tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide The Extech Instruments brand a wholly owned subsidiary of FLIR Systems Inc is ISO 9001 certified Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone s eye or allow the beam to strike...

Page 3: ...entary press Laser pointer ON OFF button 2 second press Select MAX MIN display button 6 Battery compartment 7 Power ON trigger Momentary press Display Hold ON OFF trigger 2 second press Power OFF trigger 8 Laser pointers 2 9 Infrared sensing window Display Description 1 SET and MAX MIN display 2 Temperature display 3 Reference value display 4 HOLD Laser active Buzzer On Off and Low Battery icons 5...

Page 4: ...ointers are designed to indicate the 20 distance when the laser pointers converge The spot size at this distance is a 1 diameter This is the recommended distance for most measurements To turn the lasers on off 1 Momentarily press the Min Max button 2 Repeat the press to turn the lasers off Temperature Units F or C Press and Hold the F C button for 2 seconds to change temperature units Display HOLD...

Page 5: ...rtion of the display SET button The SET button sets a degree variation from the reference value to trip the Limit LED 1 Momentarily press the SET button to display 1 0 5 0 or 10 0 degrees 2 If the scanned temperature is within the set limit the limit LED will remain green 3 If the scanned temperature is higher than the set limit the limit LED will turn red 4 If the scanned temperature is lower tha...

Page 6: ...xplode or leak IR Measurement Notes 1 The object under test should be larger than the spot target size calculated by the field of view diagram printed on the side of the meter and in this guide 2 Before measuring be sure to clean surfaces that are covered with frost oil grime etc 3 If an object s surface is highly reflective apply masking tape or flat black paint to the surface before measuring Al...

Page 7: ...avelength 630 670nm Class 2 II Laser product Spectral response 8 14um Operating temperature 0 o C to 50 o C 32 o F to 122 o F Storage temperature 20 o C to 60 o C 4 o F to 140 o F Relative humidity 10 90 RH operating 80 RH storage Power supply 9V battery NEDA 1604A or IEC 6LR61 or equivalent Weight 5 7 oz 163 g Dimensions 6 6 x 3 2 x 2 3 168 x 82 x 58 mm Range Resolution Accuracy 30 C to 20 C 22 F...

Reviews: