7
.
Orient the chip with the socket, with the notch toward the front
of the switcher.
IR receiver
IC chip
Main
controller
board
LED
U21
Figure 3 — U21 IR receiver chip socket
8
.
Carefully align each pin on the chip to its corresponding slot on
the socket.
9
.
With even pressure, press the chip into the
socket. If you encounter difficulty pressing
the chip into the socket, check to see if any
pins are bent. If so, carefully remove the
chip, straighten the pins, and try again.
10
. Apply power to the switcher by connecting
the AC power cord.
11
.
Check the IR 301’s operation by pointing the remote control
toward the IR Remote window on the front panel of the
switcher. Press the Display Power, Display Mute, RGB Mute,
and Audio Mute buttons on the remote control and verify the
corresponding buttons on the front panel lights.
12
.
After checking the operation of the switcher, put the top cover
on the switcher and replace the six screws removed in step 4.
13
.
Reconnect all input and output cables and replace the switcher
in the rack if desired.