Overview

The Extron TLP 700MV is a wall-mounted TouchLink

®

 Panel that provides simple and versatile configuration and control for a range of 

IP Link

®

 control systems.

Graphic and text objects are displayed on the screen. These objects have system control functions associated with them and the 
touch overlay allows you to activate or regulate those functions.
The TLP 700MV communicates with the configurable IP Link controller through an Ethernet connection to an IP Link device. Two BNC 
connectors allow the screen to be used to preview composite video or S-video.

NOTE: 

The RJ-45 output on the rear panel of the TLP 700MV must be connected to a network switch, hub, or router that is 

connected to an Ethernet LAN or the Internet. An Extron IP Link controller must also be connected to the same network. 
Suggested models include IPL T S series (for example, IPL T S4), IPL 250, IPL T CR 48, or IPL T SFI 244.

This guide provides basic instructions for experienced installers to mount and perform initial configuration on the TLP 700MV. Full 
instructions and reference material can be found in the 

TLP 700MV and TLP 700TV User Guide

, which is available on the Extron 

website (

www.extron.com

).

TLP 700MV Front Panel Features

LIGHTS

ON

DISPLAY

MUTE

AUDIO

MUTE

SPEECH

MUTE

AUTO

IMAGE

FREEZE

LIGHTS

OFF

SCREEN

SCREEN

HELP

?

4

4

4

5

5

5

6

6

6

1

1

1

2

2

2
3

3

3

LIGHTS

ON

DISPLAY

MUTE

AUDIO

MUTE

SPEECH

MUTE

AUTO

IMAGE

FREEZE

LIGHTS

OFF

SCREEN

SCREEN

HELP

?

7

7

7
8

8

8

9

9

9

¢

¢

¢

Figure 1. 

TLP 700MV Front Panel (left) and Front Panel with Bezel Removed to Show Recessed Buttons (right).

1

 

Buttons

 — These ten backlit push-buttons (five on either side of the screen) can be configured, using the Extron Global 

Configurator software, to control commonly used functions. 

2

 

Motion detector

 — This detector is capped with a small Fresnel lens that focuses light onto the sensor. When no motion has 

been detected for a user-defined period of time, the unit goes into sleep mode. When motion is detected in the vicinity of the 
panel, the screen display is restored and all buttons are active.

3

 

Encoder knob

 — This knob is used for volume control.

4

 

Light sensor

 — This sensor monitors the level of ambient light and adjusts the screen brightness and button backlighting.

5

 

LCD screen

 — This 800 x 480 resolution LCD screen has a touch overlay. The Extron GUI Configurator software is used to 

design a graphic user interface, which displays buttons, text, or icons on the screen. The Extron Global Configurator software is 
used to program these screen objects to perform user-defined functions.

6

 

Speaker

 — A single 2 W speaker provides audible feedback for the user.

7

 

Reboot button

 — This button is recessed behind the bezel. It shuts down and restarts the unit without changing any of the 

parameters.

8

 

Reset button

 — This button is recessed behind the bezel and is used to select from the four different reset modes that are 

available with TouchLink panels (see 

Reset Modes

 on page 3).

9

 

Menu button

 — This button is recessed behind the bezel. It activates the on-screen menus for setting up the panel and 

calibrating the unit.

¢

 

Reset LED

 — This LED is recessed behind the bezel. It is visible only when the faceplate has been removed. It lights as an 

indicator for the Reset modes.

1

Product Category

IMPOR

TANT

:

Go to 

 for th

e

complete user guide and installation

instructions befor

e connecting the

product to the power sou

rce.

www

.extro

n.com

Summary of Contents for TLP 700MV

Page 1: ...ten backlit push buttons five on either side of the screen can be configured using the Extron Global Configurator software to control commonly used functions 2 Motion detector This detector is capped with a small Fresnel lens that focuses light onto the sensor When no motion has been detected for a user defined period of time the unit goes into sleep mode When motion is detected in the vicinity of...

Page 2: ...back of the TLP 700MV Use the provided power supply for correct operation ATTENTION Do not connect any external power supplies until you have read the Attention notifications in the Power Supply section of the TLP 700MV and TLP 700TV User Guide Ne branchez pas de sources d alimentation externes avant d avoir lu les mises en garde dans la section Power Supply du TLP 700MV and TLP 700TV User Guide 8...

Page 3: ...n calibrated the screen reopens to the Setup screen Press Exit to close the on screen menus Reattach the faceplate see Figure 2 on page 2 Figure 4 Calibration Screen Reset Modes The TLP 700 MV has four reset modes that can be initiated by pressing the Reset button NOTE See the TLP 700MV and TLP 700TV User Guide at www extron com for additional details Factory Firmware Mode Hold the Reset button wh...

Page 4: ...ions to the buttons and screen graphics and text When the functions have been assigned to all screen objects build the project and upload it to the IP Link controller For complete information consult the user guide for the controller Designing the TLP 700MV Interface with GUI Configurator Install the GUI Configurator software on a PC and use it to design the interface that will appear on the TLP 7...

Reviews: