Page 2: ...ndicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at point 15 17 FAAC declines all liability as concerns safety and efficient operation of the automated system if system components not produced by FAAC are used 18 For maintenance strictly use original parts by FAAC 19 Do not in any w...

Page 3: ...m stick on the warning stickers as shown in the instruction Install the manual release devices at a height of not over 180cm Install the external control devices at a height of not below 150 cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing check if the anti crushing device is able to detect a 50mm high object on the ground a...

Page 4: ...1 TECHNICAL SPECIFICATIONS MODEL 531EM Power supply Vac 6 10 50Hz 230 Electric motor Vdc 24 Maximum absorbed power W 220 Thrust force N 600 Type of use Continuous Minimum distance from ceiling mm 35 Courtesy light Vac W 230 25 max Courtesy light timer sec 120 Standard speed of carriage load free m min 6 6 Lower speed of carriage load free m min 3 8 Deceleration speed m min 1 3 Noise at standard sp...

Page 5: ...s Check correct balance and if the opening mechanical stops have been installed 4 DESCRIPTION Remove the door s mechanical closing devices so that the door is closed by the automatic system Check if there is an efficient earth plate for electrical connection of the operator Make sure there is a clearance of at least 35 mm between the ceiling and the highest sliding point of the door fig 4 Check if...

Page 6: ...fig 7 ref A 4 Tighten the chain a little by tightening the nut fig 7 ref C 5 Place the sliding guide on its side fig 8 6 Push the carriage near the drive coupling unit fig 8 ref C 7 Adjust the tensioner fig 8 ref A so that the central part of the loop formed of the upper section of the chain coincides approximately with middle of the sliding guide fig 8 ref B Warning overtightening can damage the ...

Page 7: ...e on the lintel corresponding to the max height reached by the door during movement see fig 4 3 Position the front connection fixing bracket with bottom edge at least 5 mm above the intersection point of the lines and centred with the vertical line fig 12 See par 7 2 for correct positioning of the bracket with respect to the connection point on the door 4 Mark the two fixing points 5 Drill the hol...

Page 8: ...l brackets proceeding as described in steps 9 10 and 12 fig 15 7 2 CONNECTION ON DOOR 1 Assemble the connection bracket with the carriage bar fig 16 If using the outside release device position the connection bracket on the door so that the release wire loop is turned towards the left side of the door fig 16 and 17 2 Close the door and bring the carriage near it 3 Position the connection bracket o...

Page 9: ...lly fig 22 4 Pull the release handle sideways in the direction of the door fig 23 Check that on releasing the handle the LOCK window located under the carriage is red Manually move the door until locating the carriage coupling point Attention make sure that there are no persons animals or objects in the door movement area during the release manoeuvre 7 5 OUTSIDE RELEASE If the automatic system is ...

Page 10: ...FSW TX FSW Terminal for connection of the negative pole of the photocell transmitter TX CONNECTOR J2 low voltage Connector J2 is used for quick connection of MINIDEC DECODER and RP RECEIVER cards Insert and remove the cards after disconnecting the power to the operator TERMINAL BOARD J3 high voltage Terminal board for 230Vac 50Hz power supply on the support plate Earth fixing screw fig 26 ref A TE...

Page 11: ...revent any electrical interference use separate sheaths The operator is equipped with a cable with Shuko plug already wired if using a different cable make sure to connect the earth to the special anchoring point indicated in fig 26 ref A For the cable passage use the arrangement located on the back of the housing If tubing is used execute the slot as shown in fig 26 ref B Carry out the electrical...

Page 12: ...for 1 second The courtesy light starts to flash when the button is released 1 After 8 seconds the operator automatically does a closing operation until detecting the ground stop 2 The operator starts the opening movement Wait until it reaches the opening end travel or effect an OPEN command in the position in which stopping of movement is required 3 The operator closes the door 4 Wait until the do...

Page 13: ... 5 seconds On releasing the button the courtesy light starts flashing Carry out the following procedure within 4 seconds otherwise the operator carries out automatic SET UP 1 Effect the 1st OPEN command the operator carries out a closing operation until detecting the ground stop 2 Effect the 2nd OPEN command the operator carries out an opening movement 3 Effect the 3rd OPEN command to establish th...

Page 14: ...the automatic system does not carry out any operation The STOP and FSW safety devices are active even during the learning phase Their incorrect connection or non connection inhibits operator operation Check the status of the LEDS following the indications given in the Input LEDs status tables Check the connections given in fig 27 The automatic system does not perform any movement The STOP command ...

Page 15: ...pecial antenna To install the antenna on the automatic system drill the housing from the inside in the controlled area fig 34 and fix the antenna with the special nut fig 35 Using the RP2 868SLH receiver the second channel can be used for the STOP command or for activating other devices e g lighting systems using the free contact output The buffer battery kit will activate the automated system in ...

Page 16: ...ance as the new closing contact point and goes into closed status To restore the correct positions remove the obstacle and command a new cycle at the next closure the automated system will advance at low speed until it detects the closing contact point The door is normally closed when the electronic control unit receives an opening command from the remote control or from any other type of pulse ge...

Page 17: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ n a i c i n h c e T r e m o t s u C 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

Page 18: ...pen van de apparaat gehandhaafd blijven zonder zich daardoor te verplichten deze publicatie bij te werken Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachhändlerstempel Sello del Revendedor Stempel van de dealer FAAC S p A Via Benini 1 40069 Zola Predosa BO ITALIA Tel 051 61724 Fax 051 758518 www faacgroup com FAAC per la natura La presente istruzione è realizzata al 100 in carta ...