background image

1257014-GB_v1.1 

STD-1EU / STD-2EU 

 

1

 

GENERAL DESCRIPTION 

Control panel for 3/4CV single-phase motors at 230V on swing, folding and sliding garage doors for 

residential and communal use 

 
 

TECHNICAL CHARACTERISTICS

 

Panel supply 

230V

 (ac) 

Power 3/4CV 
Optional cards 

Pluggable receiver card 2 channels

 

(433.92 / 868.35 MHz) and traffic 

light card 

Security device output 

24V

 (ac) / 0,75A and autotest 

Electro-lock outlet 

12V

=

 (dc) / 1A 

Operating temperature 

-20ºC to +85ºC 

Watertightness IP54 
Equipment category 

Class II 

Sizes 225x195x85 

mm 

 
 

 

 
 
 
 

 
 
 

1  2    3  4  5    6  7  8      9 10 11 12     13 14   15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 

Summary of Contents for STD-2EU

Page 1: ...ICS Panel supply 230V ac Power 3 4CV Optional cards Pluggable receiver card 2 channels 433 92 868 35 MHz and traffic light card Security device output 24V ac 0 75A and autotest Electro lock outlet 12V...

Page 2: ...Close motor 2 STANDARD 2 EU version 27 End of run Open motor 2 STANDARD 2 EU version 28 Common buttons 29 Pedestrian button NO 30 Start button NO 31 Close button NO 32 Common buttons 33 Stop button N...

Page 3: ...V Flash light contact DESTELLO Voltage free maintained contact to activate a Flash light max 250V 12A Electro lock ELECTRO 12V output timed for 2 seconds to activate an electric latch of a maximum of...

Page 4: ...ling Minimum Maximum Motor operating 3s 120s Wait for automatic close 3s 120s Gap between motors 0s 120s LIGHT INDICATORS Function Indicates Default status POWER Alimentation Normally on SEG Security...

Page 5: ...ps if the end of run has not been reached and the automatic standby timer begins When pressed for the fifth time the automatic standby timer stops and motor 2 is started to close When pressed for the...

Page 6: ...g the panel check that the door is in good mechanical condition correctly balanced and that it opens and closes correctly Install the manual unlocking device at a height lower than 1 8m Install any pe...

Page 7: ...ls on how to use the manual unlocking device must be provided by the manufacturer or the device installer Examine the installation frequently especially the cables springs and supports to detect signs...