background image

Manual de servicio

NIGHT13

 

6909630100

 

NIGHT19

 

6909690100

 

NIGHT25           

 6909700100

IMPORTANT SAFETY INFORMATION

: Always read this manual first before attempting to service this 

fireplace. For your safety, always comply with all warnings and safety instructions contained in this 

manual to prevent personal injury or property damage.

Summary of Contents for 6909630100

Page 1: ...HT25 6909700100 IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to service this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage ...

Page 2: ...TENTS Operation Additional key Combinations Maintenance Exploded Parts Diagram NIGHT 13 Exploded Parts Diagram NIGHT 19 Exploded Parts Diagram NIGHT 25 Wiring DiagramS Preparation for Service Main Control Board Replacement LED Power Distributor Replacement Only NIGHT19 25 Power Supply Replacement Capacative Controls and Display Replacement Media LED light Strips Replacement Flame LED Strips Replac...

Page 3: ...he corresponding button on the remote when the heater is on Indicated by the Display and a reduced fan speed G Heat Boost Turns the Heater Boost On and Off Runs the unit at the full rated wattage OPERATION Figure 1 General Operation WARNING This electric firebox must be properly in stalled before it is used This firebox operates with Comfort averTM technology which automatically adjusts the fan sp...

Page 4: ...he second digit on the Display changing to show H high and L low J Sleep Timer The Sleep Timer can be set to automatically shut off the fireplace after a preset time from 30 minutes to 8 hours To set the timer press the timer button on the remote repeatedly until the desired time is displayed The Display will display the different times as it is ad justed Once the timer has begun pressing the butt...

Page 5: ... factory dur ing the assembly operation During shipment installation handling etc the partially reflective glass may collect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the partially reflec tive glass can be cleaned with a damp cloth The partially reflective glass should be completely dried with a lint free cloth to prevent wa...

Page 6: ...890100RP 8 Front Glass 5902900100RP 9 Flicker Motor 2000500900RP 10 Flicker Assembly 5902920100RP 11 6 Light LED Flame Assembly 3001670100RP 12 8 Light LED Flame Assembly 3001670200RP 13 4 Light RGB LED Assembly 2 3001570400RP 14 Media Tray 5902910100RP 15 6 Light Coloured Media LEDAssembly 3001570100RP 16 8 Light Coloured Media LEDAssembly 2 3001570300RP 17 Mounting Hardware Kit 9600350100RP 18 L...

Page 7: ...icker Motor 2000480200RP 10 Flicker Assembly 5902920200RP 11 6 Light LED Flame Assembly 3001670100RP 12 8 Light LED Flame Assembly 2 3001670200RP 13 Media Tray 5902910200RP 14 6 Light Coloured Media LEDAssembly 3001570100RP 15 8 Light Coloured Media LEDAssembly 5 3001570300RP 16 Mounting Hardware Kit 9600350100RP 17 Large Acrylic Media 1400130300RP 18 Medium Acrylic Media 2 1400150100RP 19 LED Pow...

Page 8: ...licker Motor 2000480200RP 10 Flicker Assembly 5902920300RP 11 6 Light LED Flame Assembly 5 3001670100RP 12 Media Tray 5902910300RP 13 6 Light Coloured Media LEDAssembly 5 3001570100RP 14 8 Light Coloured Media LEDAssembly 4 3001570300RP 15 Mounting Hardware Kit 9600350100RP 16 Large Acrylic Media 1400130200RP 17 Medium Acrylic Media 2 1400150100RP 18 LED Power Distributor 3001720100RP Accessories ...

Page 9: ...A LED ASSEMBLY MEDIA LED ASSEMBLY POWER ADAPTER FAN FAN CERAMIC ELEMENT FLICKER MOTOR FLAME LED ASSEMBLY MEDIA LED ASSEMBLY MEDIA LED ASSEMBLY POWER ADAPTER FAN FAN CERAMIC ELEMENT POWER ADAPTER RELAY BOARD MAIN CONTROL BOARD MAIN CONTROL BOARD THERMISTOR THERMISTOR NIGHT 13 NIGHT 19 NIGHT 25 ...

Page 10: ...y differ for the NIGHT 19 and NIGHT 25 1 Turn the breaker off at the electrical panel 2 Remove the front glass assembly by removing the 2 screws 1 on the left and 1 on the right side located just inside the top front vent opening These screws secure the front glass panel to the inside of the fire place Figure 4 3 Lift the front glass assembly out of the unit and care fully place the glass assembly...

Page 11: ... as above LED POWER DISTRIBUTOR REPLACEMENT ONLY NIGHT19 25 WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons CAUTION If unit was operating prior to servicing allow at least 10 minutes for lights and heating elements to cool off to avoid accidental burning of skin Tools required Phillips head screwdriver CAUTION Follow ...

Page 12: ...ructions before proceeding 1 Remove the plastic media tray by removing the 4 screws 2 on the left and 2 on the right of the tray Figure 7 2 Lift the plastic media tray out of the unit 3 Remove the front panel by removing the 6 screws 3 on the left and 3 on the right of the tray 4 Locate the LED assembly that needs to be removed 5 Disconnect the wiring connections at either end 6 Remove the assembl...

Page 13: ...y removing the 6 screws 3 on the left and 3 on the right of the tray 4 Remove the upper access cover located on the bottom right hand side by removing the screws securing it to the unit 5 Remove the left most flame panel figure 6 the 2 verti cal screws on the right hand side of the center flame panel may need to be removed to easily pull the left flame panel out 6 Remove the flicker motor mounting...

Page 14: ...ns before proceeding 1 Remove the 10 screws that secure the heater assem bly retaining bracket to the unit Remove the bracket and set aside 2 Locate and remove the 4 screws that secure the as sembly to the unit CAUTION When removing the blower assembly mount ing screws support the assembly to prevent any damage to the unit 3 Disconnect the wiring connections noting their original locations NOTE Us...

Page 15: ...on Section The batteries in the remote control are dead Install new battery into the remote control Defective remote control Replace the remote control Defective capacative control assembly Replace the capacative control assembly Defective main control board Replace the main control board Flame Frozen Loose wiring Check wiring connections Defective Flicker Motor Replace Flicker Motor Defective mai...

Page 16: ... heater is burning off any dust accumulated dur ing manufacturing or operation Defective Heating Element Replace Heating Element Heater fan turns On but heater lacks heat Improper operation Refer to Operation Section Heater turned off too early If the heater is turned off before it has run for 2 min utes the fan will continue to run for 2 minutes to fully cirulate air Loose wiring Trace wiring in ...