background image

 

Installation manual 

Fyn 600 

ENG 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

40011131-2006 

 

Summary of Contents for Fyn 600

Page 1: ...Installation manual Fyn 600 ENG 40011131 2006 ...

Page 2: ...Installation manual Fyn 600 1 ...

Page 3: ...Installation manual Fyn 600 2 ...

Page 4: ...Installation manual Fyn 600 3 1 0 1 2 1 3 1 4 ...

Page 5: ...Installation manual Fyn 600 4 2 0 2 1 2 2 2 3 2 4 2 5 2 6 ...

Page 6: ...Installation manual Fyn 600 5 2 7 3 0 3 1 3 2 3 3 3 4 ...

Page 7: ...isable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space The appliance ...

Page 8: ... local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roof overhangs and balconies Roof edges with the exception of the ridge edge see chapter 15 C11 outlet via facade Through a wall or façade use a Faber wall outlet Depending on the flue calculation this can be 100 150mm or 130 200mm C3...

Page 9: ...justable concentric flue pipe on the appliance Horizontal sections should be installed to allow a slope towards the appliance 3 degrees Built the system from the appliance If this is not possible you can make use of an extendable adapter section For fitting of the flue system the 0 5m length adjustable pipe must be used Make sure that the inner pipe is always 15mm longer than the outer pipe Wall a...

Page 10: ...to create a nice glow bed Install the front glass and check the fire image 6 2 Pebbles See the supplied decoration instruction card or chapter 18 2 Divide the pebbles over the entire bottom Avoid a double layer Please note Keep the pilot flame free from pebbles Start the fireplace as described in the user manual Assess whether the flame distribution is good Move or remove any pebbles Install the f...

Page 11: ...at the highest point If the ratio is greater than 1 100 or flue gases are measured in the air supply check the points in section 7 1 8 Instructions for client Recommend that the fire should be checked annually by a qualified specialist to ensure the safe use and to guarantee a long service life Provide instructions on the operation of o the appliance o the remote control o if present the App and i...

Page 12: ...orizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are elbows entirely in the horizontal plane fig 12 1 12 2 and 12 3 I K and Q Elbows 45 or 30 in the horizontal plane Horizontal elbows are elbows entirely in the...

Page 13: ...0 60 00 60 00 50 00 40 00 x x x x 12 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 13 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 14 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 15 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 16 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 17 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 18 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x...

Page 14: ...Installation manual Fyn 600 13 12 Examples flue materials ...

Page 15: ...ction x 1 5 45 Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Value Starter length STL First part on top of the appliance Flue length from 0 1m till 0 45m Flue length from 0 5m till 0 90m Flue length from 1m till 1 4m Flue length from 1 5m till 2m Flue length 2m or more Bend 90 Bend 45 30 or 15 Roof terminal Wall terminal Calculation Total rounded value Total Vertica...

Page 16: ...irst an adjuster to 130 200 and 1 meter 130 200 after that reduce to 100 150 and everything 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and THL and enter the value that is found If the detected value is a number check whether the completed STL is higher or equal to the value in the table Is the STL value lower as specified in ...

Page 17: ...nergy efficiency index EEI 87 87 87 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Fyn 600 Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 11 0 11 kW Other control options One step hea...

Page 18: ...n outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof...

Page 19: ...Installation manual Fyn 600 18 16 Troubleshooting guide ...

Page 20: ...Installation manual Fyn 600 19 ...

Page 21: ...Installation manual Fyn 600 20 ...

Page 22: ...Installation manual Fyn 600 21 17 Dimensional drawings 17 1 Fyn 600 ...

Page 23: ...Installation manual Fyn 600 22 17 2 Remote access door article number A9299463 ...

Page 24: ...Installation manual Fyn 600 23 17 3 Ventilation grid article number A9296400 ...

Page 25: ...Installation manual Fyn 600 24 18 Decoration instruction card 18 1 Log set ...

Page 26: ...Installation manual Fyn 600 25 18 2 Pebbles ...

Page 27: ...Installation manual Fyn 600 26 ...

Page 28: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: