background image

BOLLARD WITH RETRACTABLE CYLINDRICAL POST

OIL-HYDRAULICALLY OPERATED

GB

Instructions manual

pages

the gate opener

1 - 20

EN 13241
EN 12453
EN 12445

Summary of Contents for TALOS Series

Page 1: ...BOLLARD WITH RETRACTABLE CYLINDRICAL POST OIL HYDRAULICALLY OPERATED GB Instructions manual pages the gate opener 1 20 EN 13241 EN 12453 EN 12445...

Page 2: ...e safety accessories such as photocells sensitive edges etc Carry out a risk analysis by means of appropriate instruments measuring the crushing and impact force of the main opening and closing edge i...

Page 3: ...an area The TALOS series includes a vast selection of options as indicated below varying in height thickness and depth of embedding constraint for impact resistance the abbreviation HRC identifies th...

Page 4: ...triangular socket end Post cover with rubber edge n 9 Led lights flashing amber in colour Back reflecting sticker with logo Box to house the electric cable from the electronic controller Cover plate C...

Page 5: ...supply cable 9 Post for Fit 55 photocell projector 10 Oil hydraulic bollard Talos series 11 Vix 53 remote control transmitter 12 Post for Fit 55 photocell receiver 13 Visual 344 post to take command a...

Page 6: ...own into the pre holed seats NOTE WELL make sure the ground cable is disconnected from the casing before lifting Carefully hoist and remove the inner assembly of the bollard by a winch Make sure the c...

Page 7: ...ead the electric cables through it from a junction box or directly from the electronic controller Elpro S40 Pic 6 NOTE WELL the foundation casing is to be set perfectly levelled and the upper edge mus...

Page 8: ...r than the surrounding walking surface in order to limit the amount of water that may get inside it Cast concrete all around the casing up to 5 10 cm from walking level Wait all the time required for...

Page 9: ...al see catalogue Pre assembled loop 12 metres circumference optional see catalogue Power supply cable max 10 metres pre fitted to the loops Detector for metallic masses See the instructions supplied w...

Page 10: ...allation as required either for public or private users and in compliance with the existing safety norms A screw is provided for proper connection For applications in public areas use a cable having a...

Page 11: ...B of the Elpro S40 controller unless required to achieve a good performance of the bollard For the Talos option 12 mm thickness a 20 F capacitor is required to be added to the terminals A and B of El...

Page 12: ...he electric power is supplied check the status of the LEDs first of all as follows with the post in down posistion the L8 LED must be OFF while L9 must be ON if not swap the connections to terminals 1...

Page 13: ...nce of the bollard For the Talos option 12 mm thickness a 20 F capacitor is required to be added to the terminals A and B of Elpro S40 common common connections to the electric motor of the hydraulic...

Page 14: ...HE POST BE ASSISTED TO REACH THE FULLY FLAT DOWN POSITION Retractable Oil hydraulic Bollard English Pic 21 Pressure switch adjustment 1 Unscrew the M5 pin 2 Adjust the sensitivity using an allen key s...

Page 15: ...pment to release the unit and allow manual lowering ATTENTION once the post has been manually lowered rising can be made possible only by powering the system and pulsing it to rise Pic 23 Help the pos...

Page 16: ...tion date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be mad...

Page 17: ...ic board controlling the bollard s e g flooded relay contacts oxidized terminal clamps etc Check the correct functioning and positioning of the limit switches Check the release system for bollard manu...

Page 18: ...interfere with it 6 Make sure that electromagnetic sources are at a suitable distance from the accessories especially from the loop detectors The magnetic fields of other sources might affect the dete...

Page 19: ...ion impact resistance 90 000 J breakout resistance 550 000 J Static load max 1 500 kg in standing position max 20 000 kg in lowered position Working temperature 40 C 80 C Supply voltage 230 Vac 10 50...

Page 20: ...out 12 Vdc 600mA LED lights 12 Vdc Post material S235JRH 4 mm steel S355J2H 12 mm steel AISI 304 inox AISI 316 inox brushed SS steel standard HRC Impact resistance thick 4 52 000 J 70 000 J Crash resi...

Reviews: