Measuring transducer SEPARIX

Measuring transducer SEPARIX

Measuring transducer SEPARIX

Measuring transducer SEPARIX----Control

Control

Control

Control    CT

CT

CT

CT    

Mode of operation

Mode of operation

Mode of operation

Mode of operation    

The measuring transducer SEPARIX-Control CT is used for the power supply and analysis of the oil separator 
sensor SEPARIX-C .. and the high-level sensor SEPARIX-T .. . Alarms and malfunctions are signalled optically 
and acoustically by means of light-emitting diodes and a built-in buzzer. External alarm transmitters can be 
connected via potential-free changeover contacts, which are switched in the case of an alarm. The acoustic 
alarm  can  be  acknowledged  using  the  Alarm  button.  The  optical  alarm  remains  on  until  the  cause  of  the 
alarm has been eliminated. An internal switch can be used for an optional setting to determine whether or 
not  external  alarm  transmitters  can  be  reset  at  the  potential-free  changeover contacts. Additional internal 
setting options are the automatic alarm repeating function after 24 hours, changeover contact switched in 
the alarm or normal state, and whether the alarm is to be activated for the detection of liquid or air. The 
function test for the internal and external alarm functions can be carried out using the Test button.  

Installation

Installation

Installation

Installation    

Connecting  the  auxiliary  power,  the  oil  separator  sensor,  the  high-level  sensor  and  an  optional,  external 
alarm  transmitter  must  be  carried  out  according  to  the  connection  diagram.  The maximum values for the 
operating parameters mentioned on the wiring diagram must be observed. 

Wiring  work  may  only  be  performed  with  the  equipment  in  de-energized  condition.  The  special  VDE 
regulations and the local installation regulations must be observed.  

Operating instructions

Operating instructions

Operating instructions

Operating instructions    

Before  being  put  into  service,  all  devices  must  be  checked  with  respect  to  correct  connection  and  proper 
operation. The electrical power supply, including the supply of the downstream devices, must be checked. 

The general operating instructions for the devices being used must be observed. The measuring transducer 
is maintenance-free.  