background image

(Ref: 1801)

 

8065

CNC

Panel PC.

 

Summary of Contents for 8065 M

Page 1: ... Ref 1801 8065 CNC Panel PC ...

Page 2: ...p to the user to keep the unit virus free in order to guarantee its proper operation Computer viruses at the CNC may cause it to malfunction FAGOR AUTOMATION shall not be held responsible for any personal injuries or physical damage caused or suffered by the CNC due a computer virus in the system Ifacomputervirus isfoundinthesystem the unitwillnolongerbeunderwarranty All rights reserved No part of...

Page 3: ... 3 2 2 Connecting to an ethernet network via the PC panel 46 3 2 3 Connecting to an Ethernet network through a switch 47 3 3 Dimensions 48 3 4 Enclosure and mounting of the module 49 3 4 1 Ambient characteristics of the enclosure 49 3 4 2 Enclosure design 49 3 4 3 Securing the module 51 3 5 Voltage supply for the module 53 3 6 Hardware functionalities 54 3 6 1 Rear keyboard 54 3 6 2 Monitor lower ...

Page 4: ... Hardware functionality Connectors 82 4 7 Connection 84 4 7 1 Ethernet Fast Ethernet Gigabit Ethernet 84 CHAPTER 5 FAGORCONNECT APPLICATION 5 1 Installing the application 85 5 2 The FagorConnect application 86 5 3 Configure the application 87 5 4 Work modes 88 5 5 Diagnosis 89 5 6 Accessing Panel PC resources from the CNC 89 ...

Page 5: ...k 1 Basic Pack 1 Number of execution channels 1 1 to 2 1 to 2 1 to 4 Number of axes 3 to 5 5 to 7 5 to 12 8 to 28 Number of spindles 2 2 3 to 4 3 to 4 Maximum number of axes and spindles 7 9 16 32 Number of tool magazines 1 1 to 2 1 to 2 1 to 4 Limited to 4 interpolated axes Option Option Option Option Basic characteristics 8065 M 8065 M Power 8065 T 8065 T Power Number of handwheels 1 to 12 Type ...

Page 6: ...th the remote modules CANopen CANopen CANfagor CANopen Sercos Digital inputs per module 8 24 48 16 48 Digital outputs per module 8 16 32 16 32 Analog inputs per module 4 4 8 Analog outputs per module 4 4 4 4 Inputs for PT100 temperature sensors 2 2 Feedback inputs 4 4 Customizing on an open system only PC based open system fully customizable INI configuration files Tool for display configuration F...

Page 7: ... has been installed it is recommended to close the CNC in order to prevent the operators from installing other kinds of applications that could slow the system down and affect the machining operations SOFT DIGITAL SERCOS Sercos digital bus Sercos digital bus SOFT EDIT SIMUL EDISIMU mode editing and simulation It allows for the editing modification and simulation of a part program SOFT DUAL PURPOSE...

Page 8: ... the element SOFT KINEMATIC CALIBRATION Kinematics calibration This work mode may be used to calibrate kinematics for the first time and to re calibrate it every so often to correct any possible deviations originated by the day to day machine work SOFT HSSA II MACHINING SYSTEM HSSA II machining system This is the new version of algorithms for high speed machining HSC This new HSSA algorithm allows...

Page 9: ...or the CNC is available in the downloads section of FAGOR S corporate website http www fagorautomation com Type of file Declaration of conformity WARRANTY TERMS The warranty conditions for the CNC are available in the downloads section of FAGOR s corporate website http www fagorautomation com Type of file General sales warranty conditions ...

Page 10: ...BLANK PAGE 10 ...

Page 11: ...Panel PC CNC 8065 11 REF 1801 VERSION HISTORY CNC 8065 Here is a list of the features added to each manual reference Ref 1709 Ref 1801 First version Corrected errors ...

Page 12: ...BLANK PAGE 12 ...

Page 13: ...le the connectors with the unit connected to AC power Before handling these connectors I O feedback etc make sure that the unit is not powered Interconnection of modules Use the connection cables provided with the unit Use proper cables To prevent risks only use cables and Sercos fiber recommended for this unit To prevent a risk of electrical shock at the central unit use the proper connector supp...

Page 14: ...coils contactors motors etc uncoupled Use the proper power supply Use an external regulated 24 Vdc power supply for the keyboard operator panel and the remote modules Connecting the power supply to ground The zero Volt point of the external power supply must be connected to the main ground point of the machine Analog inputs and outputs connection Use shielded cables connecting all their meshes to ...

Page 15: ... REF 1801 Symbols that the product may carry Ground symbol This symbol indicates that that point must be under voltage ESD components This symbol identifies the cards as ESD components sensitive to electrostatic discharges ...

Page 16: ...BLANK PAGE 16 ...

Page 17: ...75 lb 2 Attach a label to the device indicating the owner of the device along with contact information address telephone number email name of the person to contact type of device serial number etc In case of malfunction also indicate symptom and a brief description of the problem 3 Protect the unit wrapping it up with a roll of polyethylene or with similar material When sending a central unit with...

Page 18: ...BLANK PAGE 18 ...

Page 19: ...sure to clean the unit because it could cause the accumulation of electrostatic charges that could result in electrostatic shocks The plastics used on the front panel are resistant to grease and mineral oils bases and bleach dissolved detergents and alcohol Avoid the action of solvents such as chlorine hydrocarbons venzole esters and ether which can damage the plastics used to make the unit s fron...

Page 20: ...BLANK PAGE 20 ...

Page 21: ...hine that integrates this CNC meets the 89 392 CEE directive Safety conditions In order to avoid personal injuries and damage to this product or to those connected to it read carefully the section on safety conditions in the introduction to this manual Fagor Automation shall not be held responsible of any physical damage or defective unit resulting from not complying with these basic safety regula...

Page 22: ...Panel PC CNC 8065 1 22 REF 1801 PREVIOUS INFORMATION ...

Page 23: ...on with the central unit This monitor may be the only one connected to the central unit for example with the central unit MCU or it may be a second monitor for example with the central unit ICU When there are two monitors both display the same video signal Module Description MONITOR 21W MULTITOUCH 21 5 1920 1080 monitor aspect ratio 16 9 24 bit color Multi touch MONITOR 21W MULTITOUCH NEUTRO 21 5 ...

Page 24: ...ion random Degree of protection Front complies with standard IP65 Power supply Power use one of the following options 24 V DC via Phoenix type connector recommended 12 V DC via DC jack connector consult Fagor Automation Maximum consumption 25 W LCD Type TFT LED LCD FullHD Screen 10 point multi touch capacitive Size 21 5 aspect ratio 16 9 Screen color 24 bits 16 7 million colors Resolution 1920 108...

Page 25: ...TITOUCH NEUTRO VGA T S USB CNC U65 CNC U70 HORIZONTAL KEYB VERTICAL KEYB Connection Description VGA VGA video signal input Maximum length 5 m 16 40 feet T S USB Touch screen driver recommended Maximum length 5 m 16 40 feet USB 2 0 Connection of a USB keyboard to the monitor Maximum cable length 800 mm 2 62 ft CAN Connection of keyboards and operator panels Maximum length of bus 500 m 1640 ft for C...

Page 26: ...Panel PC CNC 8065 2 26 REF 1801 MONITOR 21 MULTITOUCH 2 3 Dimensions mm inch a 558 40 21 98 b 349 80 13 77 c 40 70 1 60 d 47 70 1 88 mm inch Da 548 00 21 57 Db 339 25 13 36 Da c Db a b d ...

Page 27: ...nnected respecting their radius of curvature Respect the minimum distances recommended between the enclosure walls and the hardware to let the air flow and improve heat dissipation Dimensions of the cut off part and the enclosure To meet the previous requirements Fagor recommends the following The enclosure must not have any ventilation holes because they could let dust or other substances in Befo...

Page 28: ...gtheunit See 2 4 1 Enclosure design on page 27 The module is mounted from inside the enclosure Once the unit has been inserted into the enclosure secure it from the inside with the tension jacks To properly secure it use all the tension jacks on the back of the unit Apply a tightening torque of 0 7 Nm 1 Use the two top screws A to fasten the pressure hooks B 2 Use the two bottom stop screws C 3 Re...

Page 29: ...Panel PC CNC 8065 2 29 REF 1801 MONITOR 21 MULTITOUCH 4 Fasten the monitor on the rear using all the fastening hooks D D 1 2 0 7 Nm ...

Page 30: ...agor Automation before using the 12 V DC option 24 V DC universal power supply Option recommended by Fagor Automation to power the monitor Power the monitor with a 24 V DC 10 1 5 A power supply Power supply cable characteristics Use generic 12 AWG 4 mm to 18 AWG 1 mm cable Consumption Maximum consumption 25 W Never connect both power systems at the same time Pin Signal Function 1 2 11 0 V referenc...

Page 31: ...s to configure the monitor are on the back Button Description Turns the monitor on and off Automatically adjusts the clock phase horizontal position and vertical position Increases the brightness Reduces the brightness Activates the OSD menu Changes the video input source Power Auto Exit Right Source Left Menu Sel ...

Page 32: ...g in part 9 pin female SUB D HD connector Pin Signal Function 1 DCD Data Carrier Detect 2 RxD Received Data 3 TxD Transmit Data 4 DTR Data Terminal Ready 5 11 Ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator 1 5 6 9 Touch controller Fagor Automation recommends using the USB driver for the touch screen Consult Fagor Automation before using the RS232 driver i...

Page 33: ...n part 3 pole Phoenix type connector 5 08 mm pitch Rated current 16 A Pin Signal Function 1 2 11 0 V reference signal 3 24 V Power supply 1 DC jack connector for the external current adapter See 2 5 Voltage supply for the module on page 30 Power supply FagorAutomationrecommends24VDCpowerforthemonitor Consult FagorAutomationbeforeusing the 12 V DC option Power supply Never connect both power system...

Page 34: ...ic installations such as cable carrying chains For further information refer to the Ordering Handbook VGA cable Type Shielded Flexibility Normal Impedance 75 Maximum length 5 m 16 40 ft Plug in part 15 pin female SUB D HD type connector Pin Signal 1 MAINS 2 GREEN 3 BLUE 4 5 11 6 GND_RED 7 GND_GREEN 8 GND_BLUE 9 10 GND_SYNC 11 12 13 HSYNC 14 VSYNC 15 1 5 11 15 Consult Fagor Automation before using ...

Page 35: ... rear of the monitor have the following functionality when the OSD menu is active Button Description Main OSD menu Turns the monitor on and off OSD sub menu Turns the monitor on and off Main OSD menu Exits the OSD menu OSD sub menu Returns to the previous menu Main OSD menu Moves the selector to the left OSD sub menu Moves the selector to the left Moves the selector up and down Increases the value...

Page 36: ...OUCH 2 9 2 OSD menu To display the OSD menu press the MENU key on the back of the monitor Icon Description Video input Contrast Brightness Geometry for DVI input Temperature color Language OSD configuration Auto configuration Information Restore Exit ...

Page 37: ...ct this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Recall Value Meaning Recall Recalls the default values REC1 Recalls saved settings 1 REC2 Recalls saved settings 2 ...

Page 38: ...age OSD sub menu Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection ...

Page 39: ...on OSD sub menu Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection ...

Page 40: ...OUCH Restore OSD sub menu Exit OSD sub menu Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection ...

Page 41: ...enu are property of Advantech Co Ltd Press the Left Right keys and the following message will appear on screen Do not release the keys until the screen indicates that the operation has been completed Press the Left Right keys and the following message will appear on screen Do not release the keys until the screen indicates that the operation has been completed ...

Page 42: ...Panel PC CNC 8065 2 42 REF 1801 MONITOR 21 MULTITOUCH ...

Page 43: ... workstation for example with an integrated central unit The CNC to which the PPC 21W will be connected must have the connection enabled through the remote desktop with RDP protocol support as well as a functional Ethernet connection with the correct parameters set The FagorConnect application which can be installed on the Panel PC makes it possible to simplify the configuration of the connection ...

Page 44: ...5 W typical 100 W max Optionally the monitor can be powered using a 12 V DC current via the DC jack connector consult with Fagor Automation Screen Type TFT LED LCD FullHD Screen 10 point multi touch capacitive Size 21 5 aspect ratio 16 9 Screen color 24 bits 16 7 million colors Resolution 1920 x 1080 pixels Angle of vision 178 vertical 178 horizontal Brightness 300 cd m Contrast ratio 5000 1 typic...

Page 45: ...NAL CNC U65 CNC U70 ETHERNET ETHERNET OP PANEL Connection Description USB 2 0 Connection of a USB keyboard to the PPC 21W Use the keyboard cable Maximum cable length 800 mm 2 62 ft Ethernet Connecting the CNC to the PPC 21W Maximum cable length 100 m 328 ft Connecting the HBH3 to the PPC 21W CAN Connection of keyboards and operator panels Maximum length of bus 500 m 1640 ft for CANopen bus ...

Page 46: ...NAL CNC U65 CNC U70 ETHERNET ETHERNET OP PANEL Connection Description USB 2 0 Connection of a USB keyboard to the PPC 21W Use the keyboard cable Maximum cable length 800 mm 2 62 ft Ethernet Connecting the CNC to the PPC 21W Maximum cable length 100 m 328 ft Connecting the HBH3 to the PPC 21W CAN Connection of keyboards and operator panels Maximum length of bus 500 m 1640 ft for CANopen bus ...

Page 47: ...TOUCHPAD HBH3 HANDHELD TERMINAL CNC U65 CNC U70 OP PANEL Connection Description USB 2 0 Connection of a USB keyboard to the PPC 21W Use the keyboard cable Maximum cable length 800 mm 2 62 ft Ethernet Connecting the elements to the switch Maximum cable length 100 m 328 ft Connecting the HBH3 to the PPC 21W CAN Connection of keyboards and operator panels Maximum length of bus 500 m 1640 ft for CANop...

Page 48: ...Panel PC CNC 8065 3 48 REF 1801 PPC 21W 3 3 Dimensions mm inch a 558 40 21 98 b 349 80 13 77 c 114 41 4 50 d 121 41 4 78 mm inch Da 548 00 21 57 Db 339 25 13 36 Da Db a b d c ...

Page 49: ... the air flow and improve heat dissipation In the connector area reserve a space that allows the cables to be connected respecting their minimum allowable radius of curvature The angle of the PPC 21W with regard to the vertical position should not be greater than 30 Keep the enclosure clean To meet the previous requirements Fagor recommends the following The enclosure must not have any ventilation...

Page 50: ...closure To calculate the total surface area the enclosure must have to dissipate the heat inside we must consider the dissipated power for all the elements that generate heat inside the enclosure For example the power supply fan etc Hardware Dissipated power PPC 21W 55 W typical 100 W max Minimum recommended distance mm inch D 50 1 97 D D D D D ...

Page 51: ...jacks To properly secure it use all the tension jacks on the back of the unit Apply a tightening torque of 0 7 Nm Mounting the equipment Follow the instructions below 1 Before inserting the equipment inside the enclosure use the two upper screws A to attach the temporary fastening hooks B in the desired position These hooks facilitate the assembly by temporarily securing the module until it is per...

Page 52: ... 1801 PPC 21W 3 Rest the monitor inside the enclosure on the lower stop screws and push the top part until the pressure hooks support the monitor 4 Fasten the PPC 21W at the rear using all the attachment fixtures D D 1 2 0 7 Nm ...

Page 53: ... power 24 V DC Power the monitor with a 24 V DC 10 1 5 A power supply Panel PC power 24 V DC Power the panel PC with a 24 V DC 20 1 5 A power supply Power supply cable characteristics Use generic 12 AWG 4 mm to 18 AWG 1 mm cable Consumption Consumption 55 W typical 100 W max A Monitor power 24 V DC recommended B Monitor power 12 V DC consult Fagor Automation C Panel PC power 24 V DC A C B Both mon...

Page 54: ...tionalities 3 6 1 Rear keyboard The rear keyboard allows the monitor video signal 3 7 Configuring the video signal from the monitor to be configured and to navigate through the OSD menu 3 9 OSD On Screen Display menu Power Auto Exit Right Source Left Menu Sel ...

Page 55: ...mmended D 12 V DC IN 12 V DC supply input not recommended E DVI D Non functional on the PPC 21W F VGA VGA video signal input G Ground connection Ground connection A B C D E F G Connector data Number of poles 3 Pitch 5 08 mm Connection technique Screw connection Minimum maximum section 0 2 4 mm Rated current In 16 A Cable data Length to be stripped 7 mm See 3 5 Voltage supply for the module on page...

Page 56: ...ion LEDs J BTR Battery status LED K HDD Hard drive activity LED L PWR Power status LED A H I G B C D E F G J K L 2 USB 2 0 Type A ports Plug Play compatible The USB interface is compliant with USB EHCI specification rev 2 0 Connect the monitor s T S USB touch controller output to one of these inputs Always use the cable supplied by Fagor for the unit 2 USB 3 0 Type A ports Plug Play compatible The...

Page 57: ...ith only two cables Additionally prewritten software for half duplex RS 232 environments can be maintained without the need to be edited 24 V DC electric power supply input Connector data Number of poles 3 Pitch 5 08 mm Connection technique Screw connection Minimum maximum section 0 2 4 mm Rated current In 16 A Cable data Length to be stripped 7 mm See 3 5 Voltage supply for the module on page 53 ...

Page 58: ... PC on and off Button to activate the hardware reset function Data transmission and reception LEDs on the COM ports Battery status LED The LED is off when the battery is working well and the LED turns on when the battery requires replacing Hard drive activity LED The LED turns on when the hard drive is active otherwise the LED is turned off Power status LED The LED turns on when the panel PC is po...

Page 59: ...e IEEE 802 3ab 1000Base T specification HD Audio High Definition audio output Two Jack connectors provide a 5 1 channel audio system Bottom view A COM1 COM2 RS 232 serial line B LAN C LAN D Ethernet C HD Audio High definition audio output D HD Expansion n a A B C D Plug in part 9 pin female SUB D HD connector Pin RS 232 signal 1 DCD 2 RxD 3 TxD 4 DTR 5 11 6 DSR 7 RTS 8 CTS 9 RI 1 5 6 9 LED Meaning...

Page 60: ...gnal are on the back This keyboard is also used for the OSD menu Button Description Turns the monitor on and off Automatically adjusts the clock phase horizontal position and vertical position Increases the brightness Reduces the brightness Activates the OSD menu Changes the video input source Power Auto Exit Right Source Left Menu Sel ...

Page 61: ... PC s PCVGA output to the monitor s VGA input Cable characteristics Fagor Automation supplies the necessary cable for the VGA connection between the panel PC and the monitor Always use the cable supplied by Fagor for the unit A VGA video output on the panel PC B VGA Video input on the monitor A B ...

Page 62: ...haracteristics FagorAutomationsuppliesthenecessarycableforthetouchcontroller Alwaysusethecable supplied by Fagor for the unit Themonitorhastwodifferentoutputsforthetouchcontroller RS232andUSB Alwaysusethemonitor s T S USB output to connect the touch control to the panel PC i A The monitor s touch controller output B Generic USB 2 0 input on the panel PC A B ...

Page 63: ... MHz 100 MHz or 1000 MHz by default at 10 Mhz Use a cable having the recommended characteristics to ensure a transmission at 100 MHz or 1000 MHz Even so since the transmission speed depends on the configuration of the network number of nodes their configuration etc a 100 MHz or 1000 MHz transmission might not be stable In these cases we recommend to lower the transmission speed Characteristic Desc...

Page 64: ... 21W Element connection In order to ensure proper performance the connection cable must be inserted all the way into the connectors so they re latched This ensures that the cable is properly latched and does not come off due to vibration ...

Page 65: ...f the monitor have the following functionality when the OSD menu is active Button Description Main OSD menu Turns the monitor on and off OSD sub menu Turns the monitor on and off Main OSD menu Exits the OSD menu OSD sub menu Returns to the previous menu Main OSD menu Moves the selector to the left OSD sub menu Moves the selector to the left Moves the selector up and down Increases the value of the...

Page 66: ...9 2 OSD menu To display the OSD menu press the MENU key on the back of the monitor Icon Description Video input Contrast Brightness Geometry for DVI input Temperature color Language OSD configuration Auto configuration Information Restore Exit ...

Page 67: ... menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Recall Value Meaning Recall Recalls the default values REC1 Recalls saved settings 1 REC2 Recalls saved settings 2 ...

Page 68: ... sub menu Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection ...

Page 69: ...sub menu Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection ...

Page 70: ...store OSD sub menu Exit OSD sub menu Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection Select this menu icon using the Left and Right keys and press the Menu Sel key to confirm the selection ...

Page 71: ... property of Advantech Co Ltd Press the Left Right keys and the following message will appear on screen Do not release the keys until the screen indicates that the operation has been completed Press the Left Right keys and the following message will appear on screen Do not release the keys until the screen indicates that the operation has been completed ...

Page 72: ...Panel PC CNC 8065 3 72 REF 1801 PPC 21W ...

Page 73: ...on for example with a modular central unit or it may be a second monitor or workstation for example with an integrated central unit The CNC to which the PPC 19 will be connected must have the connection enabled through the remote desktop with RDP protocol support as well as a functional Ethernet connection with the correct parameters set The FagorConnect application which can be installed on the P...

Page 74: ...0 90 RH without condensation Vibration 5 500 Hz 1 G CF SDD SD 0 5 G HDD operating Degree of protection IP65 front IP20 rear IEC 60529 Power supply Supply voltage 12 24 V DC Consumption 12 V DC 23 W minimum 43 W maximum Consumption 24 V DC 23 W minimum 45 W maximum LCD Type TFT LCD Screen Capacitive multi touch 10 point Size 19 aspect ratio 4 3 Resolution 1280 x 1024 pixels Brightness 350 cd m Cont...

Page 75: ...ZONTAL KEYB 2 0 TOUCHPAD HBH3 HANDHELD TERMINAL CNC U65 CNC U70 OP PANEL Connection Description USB 2 0 Connection of a USB keyboard to the PPC 19 Maximum length 800 mm 2 62 feet Ethernet Connection of the PPC 19 to the CNC Maximum length 100 m 328 feet CAN Connection of keyboards and operator panels Maximum length of bus 500 m 1640 ft for CANopen bus ...

Page 76: ...5TX ETHERNET HORIZONTAL KEYB 2 0 TOUCHPAD HBH3 HANDHELD TERMINAL CNC U65 CNC U70 OP PANEL Connection Description USB 2 0 Connection of a USB keyboard to the PPC 19 Maximum length 800 mm 2 62 feet Ethernet Connecting the elements to the switch Maximum length 100 m 328 feet CAN Connection of keyboards and operator panels Maximum length of bus 500 m 1640 ft for CANopen bus ...

Page 77: ...Panel PC CNC 8065 4 77 REF 1801 PPC 19 4 3 Dimensions mm inch a 480 18 90 b 400 15 75 c 52 60 2 07 d 60 40 2 37 mm inch Da 461 18 15 Db 381 15 Da Db a b c d ...

Page 78: ...e enclosure walls and the central unit to let the air flow and improve heat dissipation In the connector area reserve a space that allows the cables to be connected respecting their radius of curvature The angle of the PPC 19 with regard to the vertical position should not be greater than 30 Keep the enclosure clean To meet the previous requirements Fagor recommends the following The enclosure mus...

Page 79: ...rface area the enclosure must have to dissipate the heat inside we must consider the dissipated power for all the elements that generate heat inside the enclosure For example the power supply fan etc Hardware Dissipated power PPC 19 12 V DC 23 W minimum 43 W maximum 12 V DC 23 W minimum 45 W maximum Minimum recommended distance mm inch D 50 1 97 D D D D D ...

Page 80: ... hole to allow to insert it easily without obstacles and without forcing the unit The module is mounted from inside the enclosure Once the unit has been inserted into the enclosure secure it from the inside with the tension jacks To properly secure it use all the tension jacks on the back of the unit Mounting the equipment 1 Installing the monitor in the enclosure 2 Fasten the monitor on the rear ...

Page 81: ...e module Monitor power 12 24 V DC Power the monitor with a 12 24 V DC power supply Consumption Consumption 12 V DC 23 W minimum 43 W maximum Consumption 24 V DC 23 W minimum 45 W maximum Power supply Pin Signal Function 1 2 V 0 V reference signal 3 V Power supply 1 ...

Page 82: ...erial lines C DVI D Video signal output D USB 2 0 1 USB 2 0 Type A ports E USB 3 0 1 USB 3 0 Type A ports F LAN 2 RJ45 LAN ports 10 100 1000 Mbps G HDD Led Hard drive activity LED red LED H Power Led Power status LED green LED I Reset Reset button J On Button to turn the panel PPC 19 on and off K 24 V DC IN 12 24 V DC electric power supply input A B C F E K D G H I J ...

Page 83: ...panel PC is powered otherwise the LED is turned off Connector data Number of poles 3 Pitch 5 08 mm Connection technique Screw connection Minimum maximum section 0 2 4 mm Rated current In 16 A Cable data Length to be stripped 7 mm See 4 5 Voltage supply for the module on page 81 LED Meaning A green Connection LED The LED turns on when the PPC 19 is connected to the data network B yellow Activity LE...

Page 84: ...e network number of nodes their configuration etc a 100 MHz or 1000 MHz transmission might not be stable In these cases we recommend to lower the transmission speed Element connection In order to ensure proper performance the connection cable must be inserted all the way into the connectors so they re latched This ensures that the cable is properly latched and does not come off due to vibration RJ...

Page 85: ...ation execute the file SetupFagorConnect exe The welcome window will appear on screen with some advice for the installation process Press the Install button to start the installation and follow the instructions that appear on screen To install the application on a Fagor Panel PC it must be in administrator mode with the disk unprotected See 5 4 Work modes on page 88 The application can be installe...

Page 86: ...ion The application will display the message Connecting while it tries to connect to the CNC via TCP IP The dwell time and the IP address of the CNC are defined in the FagorConnect ini configuration file and can be modified from the application After the dwell time if the application has not been able to establish the connection to the CNC it will display the error message Connection could not be ...

Page 87: ...meters Parameter Meaning CNC Name IP address Name or IP address of the CNC to which you wish to connect the Panel PC By default it is CNC8070 User Username for connection to the CNC By default it is CNC8070 Password Password to validate the connection to the CNC By default it is CNC8070 Connect On Startup Establish the connection to the CNC when starting FagorConnect By default No Timeout Maximum ...

Page 88: ...any operation such as install a version of FagorConnect install third party applications configure TCP IP parameters etc In user mode the entire hard drive is write protected except for the following files and folders In administrator mode the buttons Add new file folder and Remove file folder allow you to add and remove files folders in the protected files folders list The user mode does not allo...

Page 89: ...ssing Panel PC resources from the CNC The Panel PC is configured to export its resources so that the CNC can see your hard drive and any possible pen drives that are connected In order for programs from any of these storage devices to be quickly executed it is necessary to configure them from the CNC as network units This operation is completed from the Windows file explorer on the CNC File explor...

Page 90: ...Panel PC CNC 8065 5 90 REF 1801 FAGORCONNECT APPLICATION ...

Page 91: ...Panel PC CNC 8065 91 User notes REF 1801 ...

Page 92: ...Panel PC CNC 8065 92 User notes REF 1801 ...

Page 93: ...Panel PC CNC 8065 93 User notes REF 1801 ...

Page 94: ...Fagor Automation S Coop Bº San Andrés 19 Apdo 144 E 20500 Arrasate Mondragón Spain Tel 34 943 719 200 34 943 039 800 Fax 34 943 791 712 E mail info fagorautomation es www fagorautomation com ...

Reviews: