background image

 

 

 

 

 

 

 

 

 

 

 
 
 

GSM Gateway 252236 

User Manual 
 

Art. No. 162236M  V3.21D  2016-02-18 

 

 

 

 

 

Summary of Contents for 252236

Page 1: ...GSM Gateway 252236 User Manual Art No 162236M V3 21D 2016 02 18...

Page 2: ...t alarm 8 5 SMS functionality 9 5 1 Low battery voltage indication 9 5 2 Dial tone battery alarm Dial tone 2 11 5 3 Status 12 5 4 Reset 13 5 5 Ask for the current Gain 13 5 6 Change the Gain 13 6 Upgr...

Page 3: ...G The product complies with the following standards norms EN 55022 2006 and A1 2007 EN 55024 1998 and A1 2001 and A2 2003 EN 60950 2006 and ETSI EN 301 511 Ume Sweden January 2013 Mikael L ngstr m CEO...

Page 4: ...the lift phone F ltcom ECII Flex and Power SIM Lift phone F ltcom ECII Flex in LIFT CAR TELE PHONE ANT Power Supply 12 24 VDC 230 VAC OR Battery ANTENNA SIM PIN code Activated or deactivated PIN code...

Page 5: ...se a mobile phone or other equipment to set the PIN code to 1234 At startup the GSM Gateway will automatically change the PIN code to a random 4 digit code to prevent misusage of the SIM card If the S...

Page 6: ...nformation please see section 5 3 LED Indicators LED Status Indicates PWR STAT 1000 ms ON 1000 ms OFF Normal status 100 ms ON 1500 ms OFF Backup power in use PHONE Red LED OFF Phone device is On hook...

Page 7: ...ngth Green LED S1 S2 Signal strength OFF OFF Bad ON OFF Good default 15 83 dBm ON ON Very good default 25 63 dBm Flash OFF Good Backup power in use Flash Flash Very good Backup power in use LED levels...

Page 8: ...by a change of the normal dial tone see section 5 2 below The first battery test is made after 48 hours and the following every 24 hour During a battery test a load is connected to the battery and th...

Page 9: ...t changed The GSM will acknowledge a correct programming by returning a SMS In the example below the battery alarm level is changed to 4 0 V 4000 mV In this example a Low battery voltage indication wi...

Page 10: ...ge level the following is sent from the GSM Gateway Both functions described above are switched off by sending the following to the GSM Gateway The Battery replaced SMS Bares function described above...

Page 11: ...taken off hook To deactivate the Dial tone battery alarm dial tone 2 send the SMS below to the GSM Gateway The GSM will acknowledge a correct programming by returning a SMS To reactivate the dial ton...

Page 12: ...l strength signal strength in dBm S H L Highest signal during last 24h lowest signal during last 24h since last restart UT Uptime counter presented in days hours and minutes LC Last called number not...

Page 13: ...word Gain The default Access code is 1111 and can be changed using the F ltcom Manager SW If the SMS is correct the Gateway will return the Gain settings Description table of the gain SMS Parameter De...

Page 14: ...rameter for signals from alarm receiver to Flex 4 20 POTS GSM Gain parameter for signals from Flex to the alarm receiver 3 20 If the received parameters are outside the range the Gateway will set the...

Page 15: ...local distributor Use a standard USB mini USB cable to connect the GSM Gateway to the PC Install the F ltcom Manager tool on your PC Connect the GSM Gateway to the PC using a standard USB mini B USB...

Page 16: ...y F ltcom or your local distributor Note The FW file always has the file extension bin e g gatewayFW bin Click on Update During the update you can follow the progress in the status bar Note Be careful...

Page 17: ...able the Battery fault alarm but still charge the battery If the lift has a battery backup system the battery in the Gateway can be removed uncheck the Mounted battery box to disable all battery charg...

Page 18: ...not improve try positive values If the receiver has trouble receiving and deciphers DTMF sent by the emergency alarm try adjusting the POTS PHONE to GSM 6 2 6 POTS1 power saving Note Do not use this...

Page 19: ...ass IP 20 External power 10 28 VDC Power consumption At rest 12V 180mA 24V 95mA Ongoing call 12V 330mA 24V 160mA Battery type NiMH 4 8V 1250mAh Battery power consumption At rest 120 mA Ongoing call 30...

Page 20: ...th freight paid on the assumption that the product is covered by warranty If the investigation shows that the re turned product has no defects the customer is charged a service fee and freight The cus...

Reviews: