background image

- 1 -

LE-05d

Electric energy meter, 

without neutral wire

The LE-05d is a static (electronic) calibrated electricity meter, 

used as a sub-meter for indicating the consumed three-phase 

AC active electricity in the Arona metering system. 

A special electronic system under the influence of current flow 

and applied voltage in each phase generates pulses in propor-

tion to the electricity consumed in this phase. 

Phase energy consumption is indicated by flashing the corre-

sponding LED (A and C). The sum of the three phases of pulses 

indicated by a flashing LED is converted to energy taken in the 

entire three-phase system, and its value is determined by the 

segment LCD display.

Numbers after the decimal point indicate decimals (.1 kWh =100 

Wh). 

Purpose

Functioning

F&F Filipowski L.P.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: biuro@fif.com.pl

Do not dispose of this device in the trash along with other waste!  

According to the 

Law on Waste, electro coming from households free of charge and can give any amo-

unt to up to that end point of collec� on, as well as to store the occasion of the pur-

chase of new equipment (in accordance with the principle of old-for-new, regardless 

of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Summary of Contents for LE-05d

Page 1: ...to energy taken in the entire three phase system and its value is determined by the segment LCD display Numbers after the decimal point indicate decimals 1 kWh 100 Wh Purpose Functioning F F Filipowsk...

Page 2: ...equipped with pulse output This allows you to con nect another pulse device SO that reads pulses generated by the meter No additional connected equipment is required for proper operation of the meter...

Page 3: ...nd output terminal covers to pre vent any attempts to bypass the meter The meter is marked with individual serial number allowing its unambiguous identification The marking is laser engraved and canno...

Page 4: ...vers 4 Connect the voltages of the phases to be monitored as indica ted to the terminals 1 L1 3 L2 5 L3 5 Connect the circuit to be measured or a single consumer to the terminals 2 L1 4 L2 6 L3 6 Conn...

Page 5: ...5 1 L1IN phase 5 L3IN phase 2 L1OUT phase 6 L3OUT phase 3 L2IN phase 8 pulse output 4 L2OUT phase 9 pulse output Wiring diagram...

Page 6: ...ss II housing PC ABS material own power consumption 10 VA 2 W indication range 0 99999 9 kWh meter constant 800 imp kWh signalling current consumption A C phases 2 red LED read out signalling red LED...

Page 7: ...declares that the device is in conformity with the essential requirements of the Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration...

Page 8: ...d overvoltage circuit breakers Before connecting the power supply make sure that all cables are connected correctly It is essential to observe the operating conditions of the meter supply voltage humi...

Reviews: