background image

F&F Filipowski sp. j.

Konstantynowska 79/81   

tel/fax +48 42 2152383; 2270971    

e-mail: fif@fif.com.pl

95-200 Pabianice   

POLAND

http:/www.fif.com.pl   

PROGRAMMABLE CONTROL TIMER 

dual-channel

PCZ-522.3

PURPOSE

OPERATION

Programmable control timer is used to time control the devices in home or 
industrial automation systems according to an individual time program set by 
the user. 

Timer  activates  and  deactivates  the  device  or  electrical  circuit  on  the 
programmed  hours  in  cycles:  daily,  weekly,  working  days  (Mon-Fri) 
or  weekend  (Sat,  Sun).  The  timer  has  two  independently  programmable 
channels.

CHANNEL

 – program line with individual entries for ON-OFF COMMANDS, 

which controls its own contact for enabling the receiver.

ON-OFF COMMAND

 – program entry for enabling or disabling the receiver.

500 MEMORY CELLS

 – memory for individual program entries that allows to 

program

 

250 pairs of ON-OFF COMMANDS.

AUTOMATIC MODE

 

- operation by ON-OFF COMMANDS programmed by the 

user in the timer memory [highlighted 

    

 icon on display]

MANUAL MODE

 - [ON] permanently closed contact (position 1-5) or [OFF] 

permanently

 

open contact (position 1-6) when the AUTOMATIC MODE is off 

[no 

   

 

 

icon on display]

CYCLE

  -  adjustable,  weekly  cycle  (7  days  from  Monday  to  Sunday)  of  the 

receiver switching in accordance with the programmed ON-OFF COMMANDS:
* single day of the week: Mo; Tu; We; Th; Fr; Sa or Su.
* working days: Mo Tu We Th Fr (Monday to Friday).
* weekend: Sa Su (Saturday and Sunday)
* daily: Mo Tu We Th Fr Sa Su (Monday to Sunday).  

AUTOMATIC TIME CHANGE

 - change from winter time to summer time with 

options to change automatically or not. User can set the time zone so that the 
switching time is consistent with the local time

DATE PREVIEW

 - the ability to preview the set date (OK.) 

CURRENT PROGRAM PREVIEW

 – pressing the +/- keys in the date preview 

mode  displays  information  about  the  number  and  details  of  the  current 
program. 

NFC  WIRELESS  COMMUNICATION

  -  wirelessly  read  and  write  timer 

configuration  from  an  Android  phone  equipped  with  the  NFC  module.

PCZ  Konfigurator  APP

  -  free  application  for  Android  mobile  phones  and 

tablets equipped with the NFC module for wireless communication.
Features: · timer configuration in Offline mode (without the connection with 
the PCZ-521 timer);
· read and write the configuration of the controller;
· quick programming of multiple controllers using a single configuration;
· read and write the configuration from and to a file;
· sharing the configuration via e-mail, Bluetooth, network drives…
·  identification  of  the  connected  timer  and  the  ability to  name  individual 
devices;
· automatic backups of the configuration. Along with a unique identifier for 
each timer, user can easily restore previous configuration;
· set the time and date according to the clock in mobile phone;
The app is available on Google Play!

CLOCK TIME CORRECTION

 – set monthly adjustment of the seconds of the 

system clock. 

BATTERY INDICATOR

 - the controller comes with built-in control system of the 

backup timer battery  used in case of main power supply failure. If the battery 
is low, user will receive information that the battery needs to be replaced. 

Battery  life  depends  on  the  ambient  temperature  and  the  degree  of  the 
battery wear.

OPERATING MODES AND FUNCTIONS

3. TIME

Press MENU. The timer will enter the program menu. Using the 

+/-

 buttons 

select the mode for time setting

 [hour]

Timer will show settings for the next parameters: year, month, and day. Use 
the 

+/-

 keys to set the parameters; move to the next parameter with the OK 

button. Go back to the previous item by pressing MENU. 

Timer will show settings for the next parameters: hour and minutes. Set the 
parameters with the 

+/-

 buttons. Move to the next parameter with the OK 

button. Go back to the previous item by pressing MENU.

Press OK to accept date setting. The timer will automatically exit from the 
date setting mode and go to the program menu.

Press OK to accept time entry. The timer will automatically exit from the date 
setting mode and go to the program menu.

4.1 ON-OFF COMMAND - setting the parameters 

Press OK to accept (or select another number using the 

+/-

 keys). Clock  will 

enter the single ON-OFF COMMAND parameters setting mode. 

A. Operation cycle

 

Set OPERATION CYCLE using the 

+/-

 keys: 

* single day of the week: Mo; Tu; We; Th; Fr; Sa or Su.
* working days: Mo Tu We Th Fr (Monday to Friday).
* weekend: Sa Su (Saturday and Sunday)
* daily: Mo Tu We Th Fr Sa Su (Monday to Sunday)

Press OK to accept.

B. Hour and minutes

 

Timer will show setting for the next parameters: hour and minutes. Set the 
values using +/- keys; move to the next parameter with the OK button. Go 
back to the previous item by pressing MENU.

The date setting is tantamount to time determination: winter or summer. 
In Poland, the time change from winter to summer is done automatically at 
night, 

on the last Sunday of March

 at 2.00 AM (by adding one hour to the 

current time). Time change from summer to winter is done automatically at 
night, 

on the last Sunday of October

 at 3.00 AM (by subtracting one hour 

from the current time).
 

PLEASE NOTE!

 

The automatic time change can be turned off  (see section 5.1).

Using the 

+/-

 buttons select the mode for the date setting 

[prog]

.

Press OK to accept. The clock will enter the memory cell number selecting 
mode. The display will automatically show the number of the first empty 
memory cell.

Mo

T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

5

9 0 8 3 1 2

5 9 3 2 5 6

4. CHANNEL – Selecting a channel number and setting its parameters

Press MENU. The clock will enter the program menu. Using 

+/-

 buttons select 

the mode for the date setting: 

"Chn 1"

 or 

"Chn 2"

.

Select channel 1 or 2, and accept with OK button.
Timer will show the submenu of the selected channel parameter settings: 
on-off commands, edit, delete and mode select.
Select the desired entry with the 

+/-

 buttons. Open the desired item with OK 

button.OK. Press MENU button to return to the main MENU.

1

DISPLAY AND CONTROL PANEL DESCRIPTION

Mo – Monday; Tu – Tuesday; We – Wednesday; Th – Thursday; Fr – Friday; 
Sa – Saturday; Su – Sunday.

Mo T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

DATE AND TIME /

/ PROGRAM ENTRIES

MODE INDICATOR /

AUTOMATIC MODE

DAYS OF THE WEEK /

CYCLE

INDICATION OF CONTACT 
POSITION

MENU

OK

+

FUNCTION KEYS DESCRIPTION

MENU:

 

- enter the program menu 
- return to the previous position (back). 

OK:

 

- move to the next setting 
- accept setting
- preview of the date 

+ [Plus]: 

- change the setting by one position up for the selected programming option
(holding down the button continuously changes the setting by one position
up in a loop) 
- in MANUAL MODE: permanent ON and OFF contact switching 

- [Minus]:

 

- change in the setting by one position down for the selected programming
option (holding down the button continuously changes the setting by one 
position down in a loop) 
- in MANUAL MODE: permanent ON and OFF contact switching

1. START

1.1 Connect the power supply.
1.2 The timer will start at the root level and the display will show selected 
hour.

In the absence of any program entries, timer will automatically run in manual 
mode. If the previous entries are present, timer will execute the program. 
To erase all previous settings, see section 5.6.
1.3 Set individual timer program with internal configuration menu or by using 
the "PCZ Konfigurator" app for mobile devices. 

PROGRAMMING 

2. DATE

Press  MENU.  The  timer  will  enter  program  menu.  Using  the 

+/-

  buttons 

select the date setting mode 

[date]

Mo

T

U

W

E

T

H

F

R

S

A

S

U

1

OFF

Confirm with OK.

ş

2

ON

OFF

CHANNEL NUMBER

LCD BRIGHTNESS ADJUSTMENT

 - change the contrast of the display to get 

aclear LCD read-out from different viewing angles. 

RELAY STATE MEMORY

 - the relay state in manual mode will be remembered 

even after power supply failure.

ON1

OFF1

OFF2

ON1

OFF2

OFF1

* Time of contact closing established by a pair of ON-OFF commands can be 
longer than 24 hours, which means that [ON] command can be set to any 
time and any day of the week (e.g. Tuesday, 1:45 PM) and [OFF] command to 
any hour of any other day of the week (e.g. Thursday, 5.05 PM).

C. ON / OFF 

Timer will allow to choose [ON] or [OFF] option.

Set ON or OFF using +/- keys; confirm with OK. Timer will automatically enter 
the next ON-OFF COMMAND parameter input mode. Go back to the previous 
item by pressing MENU.

PLEASE NOTE! 

*  The  registered  ON-OFF  commands  do  not  constitute  solid  pairs  of 
commands for a contact opening and closing. They are treated as individual 
commands and executed in accordance with the specified time chronology. 
Cases  of  overlapping  contact  closing  times  from  two  pairs  of  ON-OFF 
commands are illustrated in the following diagrams:

ON1

contacts 1-5

entry 1

OFF1

ON2

OFF2

entry 2

ON1

OFF1

ON1

OFF1

ON2

ON2

Mo T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

Mo T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

Mo T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

Mo T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

4.2 EDITION OF ON / OFF COMMANDS PARAMETERS

Using the 

+/-

 keys select the parameter edit mode 

“edit”

Press OK to accept. The timer will enter the memory cell number selecting 
mode. Select the cell to edit and accept by pressing OK. 

Mo T

U

W

E

T

H

F

R

S

A

S

U

ş

1

ON

OFF

contacts 1-5

entry 1

entry 2

contacts 1-5

entry 1

entry 2

contacts 1-5

entry 1

entry 2

contacts 1-5

entry 1

entry 2

Proceed as with ON-OFF COMMAND parameters setting (see section 5.1).

1

Continued on page 5

-3-

-4-

-2-

-1-

Summary of Contents for PCZ-522.3

Page 1: ...e next parameters hour and minutes Set the values using keys move to the next parameter with the OK button Go backtothepreviousitembypressingMENU The date setting is tantamount to time determination winter or summer In Poland the time change from winter to summer is done automatically at night on the last Sunday of March at 2 00 AM by adding one hour to the current time Time change from summer to ...

Page 2: ...menu menu syst clear error Confirm the error option by pressing OK The timer will enter standby mode awaiting for deletion confirmation This is indicated by alternating flashingof error and clear ondisplay Confirm by pressing OK The timer will reset the error The display will show error Theclockwillreturntostandardoperationmode 5 7Systeminformation info Confirm by pressing OK The timer will enter ...

Page 3: ... RESET OK DEVICE TYPE OK OK RESET SYSTEM SETTINGS HOUR 86uf 00 00 MINUTY 00 00 HOUR OK 1 1 1 1 OK OK MINUTES OK Low batt too low level of the battery that supports the opera tion of the timer after a power failure In this case it is recom mended to replace the battery PLEASE NOTE Low battery does not preclude normal operation of the timer However in case of a timer power failure it may lead to los...

Page 4: ...e displays the current operating mode for the controller manual or automatic Applies only to operating in Online Out mode Output relay status enabled or disabled Applies only in Online mode Keys 1 Readthetimerconfiguration 2 Save the current configuration to the timer 3 Loadconfigurationfromfile 4 Save the current configuration to file 5 Restore configuration from backup copies 6 Editthecurrentcon...

Reviews: