background image

- 1 -

- 2 -

- 3 -

- 4 -

F&F Filipowski sp. j.

ul. Konstantynowska 79/81   95-200 Pabianice   

phone: (+48 42) 215 23 83; 227 09 71   POLAND

https://www.fif.com.pl   e-mail: biuro@fif.com.pl

ASTRONOMICAL PROGRAMMABLE

CONTROL TIMER

with night break

pcz-525.3 

plus

WARRANTY. 

The F&F products are cov

-

ered by a warranty of the 24 months from 

the date of pruchase. Effective only with 

proof of purchase. 

Contact your dealer or directly with us.

More information how to make a compli

-

ant can be found on the website:

www.fif.com.pl/reklamacje

Do not dispose of the device to a garbage bin with other unsorted 

waste!

 In accordance with the Waste Electrical and Electronic Equip

-

ment Act any household electro-waste can be turned in free of charge 

and in any quantity to a collection point established for this purpose, as 

well as to the store in the event of purchasing new equipment (as per 

the old for new rule, regardless of brand). Electro-waste thrown in the 

garbage bin or abandoned in the bosom of nature pose a threat to the 

environment and human health.

1. Purpose

The PCZ-525.3 Plus astronomical clock is designed to switch on and off lighting 

or other electrical receivers according to the daily astronomical sunrise or sun

-

set times calculated automatically based on the current date and the entered 

location of the controller. It is also possible to enter a fixed on/off time and 

define a night break during which the lighting will be switched off.

In combination with the external "Plus" probe brightness sensor the clock al

-

lows you to adjust the on/off moment according to the actual brightness level.

2. Operating modes

2.1. automatic mode

Automatic operation according to the preset programmed ON and OFF points. 

The clock allows for independent setting of switch-on and switch-off points ac

-

cording to the following criteria:

ƒ

ƒ

sunrise or sunset;

ƒ

ƒ

dawn or dusk (civilian dawn/ dusk);

ƒ

ƒ

a constant shift in relation to sunrise and sunset (expressed in minutes or the 

position of the sun shield relative to the horizon);

ƒ

ƒ

constant time.

Also, a night break between 

poFF

 and 

poN

 points can be set in the operating 

program during which the lighting will be switched off.

If an external brightness sensor of the "Plus" probe type is connected and acti

-

vated, it is possible to specify an additional time interval around the switch-on 

points 

oN

 (Switch-on Zone) and switch-off points 

oFF

 (Switch-off Zone) in which 

the clock will analyze the actual brightness level and on this basis decide on an 

earlier or later switch-on/off. This makes it possible, for example, to switch the 

lighting on and off earlier in case of cloudy days.

Automatic operation is indicated by the clock symbol at the bottom left of the 

display.

For correct operation in automatic mode, it is necessary to correctly 

set the location, date, and time.

2.2. semi-automatic mode

Semi-automatic operation is the ability to manually switch the contact during 

automatic operation. The change will be effective until the next switching re

-

sulting from the automatic operation cycle. An example of how semi-automatic 

mode works is shown in the diagram below:

Switching between automatic and semi-automatic mode is done by pressing 

the external button connected to terminal 4 of the clock or by pressing the 

"+" 

or 

"–"

 button located on the facade of the clock. Semi-automatic operation is 

indicated by a blinking clock symbol at the bottom left of the display.

2.3. maNual mode

In manual mode, the clock assumes a fixed on/off state set by the user by press

-

ing the external button connected to terminal 4 of the clock, or by pressing 

the "

+

"

 

or "

" button located on the facade of the clock. Manual operation is 

indicated by the switched off clock symbol.

The status of the relay in manual mode is maintained in the non-vol

-

atile memory of the clock. This means that in the event of a power 

outage and return, the clock will restore the state of the relay from 

before the power outage.

3. Features

ƒ

ƒ

1-channel 

astronomical programmable control timer with night break

;

ƒ

ƒ

automatic transition between summer (daylight saving time) and standard 

time (with the ability to block the function in the event of a change in the 

applicable legislation);

ƒ

ƒ

ability to connect an external brightness sensor to adjust the moment of light

-

ing switching on and off;

ƒ

ƒ

ability to connect an external button for manual control of the operation of 

the clock;

ƒ

ƒ

backlit LCD for clock configuration and time and operating status indication;

ƒ

ƒ

NFC WIRELESS COMMUNICATION – wirelessly read and write timer configura

-

tion from an Android phone equipped with the NFC module;

ƒ

ƒ

PCZ CONFIGURATOR APP – free application for Android mobile phones and 

tablets equipped with the NFC module for wireless communication.

Features:

ƒ

»

timer configuration in offline mode (without the connection with the timer);

ƒ

»

coordinates settings by selecting the preset location (code coordinates), a 

direct indication of the location on a map on your phone or copying the 

current position recorded by the GPS in your phone;

ƒ

»

read and write the configuration of the controller;

ƒ

»

quick programming of multiple controllers using a single configuration;

ƒ

»

read and write the configuration from and to a file;

ƒ

»

sharing the configuration via e-mail, Bluetooth, network drives...

ƒ

»

identification  of  the  connected  timer  and  the  ability  to  name  individual 

devices;

ƒ

»

automatic backups of the configuration. Along with a unique identifier for 

each timer, user can easily restore previous configuration;

ƒ

»

set the time and date according to the clock in mobile phone.

ƒ

ƒ

predefined lighting switch-on and off points:

ƒ

»

sunrise and sunset – the moment when the solar disc crosses the horizon,

ƒ

»

civilian dawn and dusk – the moment when, according to legal conditions, 

the lighting of, for example, streets should be switched off/on;

ƒ

ƒ

ability to set your own switch-on/off point interpreted as a sunrise/sunset 

shift by:

ƒ

»

preset time (within ± 180 minutes).

ƒ

»

preset position of the center of the solar disc (within ±15°);

ƒ

ƒ

ability to set the width of the time zone (in relation to the program switch-

on/off point) in which the moment of switch-on will be determined by the 

brightness level measured by the "Plus" probe sensor;

ƒ

ƒ

location table – the geographical coordinates of more than 1,500 localities 

from  51  countries  of  the  world  are  encoded  in  the  memory  of  the  timer, 

allowing  you  to  precisely  select  the  location  of  the  timer  and  ensure  high 

accuracy of the position of the sun calculation;

ƒ

ƒ

a preview of the switch-on and switch-off points and location information – if 

the timer operates in automatic mode, then in the date preview mode the 

successive presses of the Up/Down buttons will display information about the 

current time, the actual switch-on and switch-off times of the relay and about 

the set location (geographical coordinates are displayed) and the UTC zone;

ƒ

ƒ

LCD configuration – ability to set the backlight level (separately for standby 

and button-pressed condition) and display contrast;

ƒ

ƒ

relay state memory – the relay state in manual mode will be stored in the 

read-only memory of the relay at the time of a power outage and will be 

restored when the power returns;

ƒ

ƒ

2032-type replaceable battery – the controller is equipped with control of 

the battery status that maintains the timer operation in case of main power 

failure. If the battery is low, you will be notified if it needs to be replaced;

ƒ

ƒ

clock frequency correction – the ability to freely accelerate/slow the clock 

operation. For example, if, over time, the controller starts to be 5 seconds late 

per month, this deviation can be corrected.

4. Display and control panel description

4.1. days oF the week

mo

 – Monday; 

tu

 – Tuesday; 

we

 – Wednesday; 

th

 – Thursday; 

Fr

 – Friday; 

sa

 – Saturday; 

su

 – Sunday.

4.2. operatioN mode iNdicator

maNual mode

 – no clock icon,

automatic mode

 – lighted clock icon,

semi-automatic mode

 – flashing clock icon.

4.3. coNtact positioN iNdicatioN

ƒ

ƒ

OFF – relay off, closed connection between COM (terminal 1) and NC (ter

-

minal 5) contacts,

ƒ

ƒ

ON – relay on, closed connection between COM (terminal 1) and NC (terminal 

6) contacts.

4.4. buttoNs

meNu

ƒ

ƒ

enter the program menu

ƒ

ƒ

return to the previous position (back).

ok

ƒ

ƒ

move to the next setting

ƒ

ƒ

accept setting

ƒ

ƒ

preview of the date and the scheduled points of switch on/off and the lo

-

cation;

"

+

"

 [up]

ƒ

ƒ

While displaying the home screen:

ƒ

»

in automatic mode – switching on/off semi-automatic mode and switching 

the contact;

ƒ

»

in manual mode: permanent on and off contact switching.

ƒ

ƒ

In parameter edit mode:

ƒ

»

changing  the  setting  state  by  "+1"  in  the  selected  programming  position 

(holding down the button changes the setting by "+1" continuously in the 

loop).

"

"

 [dowN]

ƒ

ƒ

While displaying the home screen:

ƒ

»

in automatic mode – switching on/off semi-automatic mode and switching 

the contact;

ƒ

»

in manual mode: permanent on and off contact switching.

ƒ

ƒ

In parameter edit mode

ƒ

»

changing  the  setting  state  by  "-1"  in  the  selected  programming  position 

(holding down the button changes the setting by "-1" continuously in the 

loop).

5. Operation

Connect  the  power  supply.  The  timer  will  start  its  operation  from  the  main 

screen displaying the current time and information on the operating mode and 

switch-on/off of the output relay.

ƒ

ƒ

From the home screen, you can monitor and configure the operation of the 

device.

ƒ

ƒ

Pressing the 

meNu

 button displays the menu of the controller that allows you 

to configure the clock.

ƒ

ƒ

Pressing the OK button displays the set date. In addition, after pressing the 

ok

 button in automatic mode, by pressing the 

up

 or 

dowN

 buttons you can 

display the subsequent details of the timer: the set date, the location of the 

controller (longitude and latitude), the points of lighting switch-on and off.

In  the  case  of  operation  with  an  active  outdoor  light  sensor,  the 

switch-on and switch-off points are approximate and indicate at what 

time it will be switched on/off in the case of the currently measured 

brightness level.

ƒ

ƒ

Pressing the 

up/dowN

 button: When operating in automatic mode, the timer 

switches to the semi-automatic mode and switches the contact to the oppo

-

site position. This state will be maintained until the next program switching 

point occurs.

ƒ

ƒ

During manual operation, the relay contact is permanently switched to the 

opposite position.

The status of the relay in manual mode is maintained in the non-vol

-

atile memory of the clock. This means that in the event of a power 

outage and return, the clock will restore the state of the relay from 

before the power outage.

The clock can also be controlled via an external momentary button connected 

to terminal 4. Short press (<1 s) of the external button has a similar function to 

the 

up/dowN

 button pressing described above. Long press (>2 s) of the exter

-

nal button, when operating in automatic or semi-automatic mode, forces the 

clock to return to automatic mode.

In specific cases, additional messages may appear on the screen to 

inform about errors or requiring user intervention.

5.1. low battery

The 

low batt

 message indicates that the battery backup clock is too low after a 

power outage. In this case, battery replacement is recommended.

The user can replace the battery by himself with a new, type 2032 lithium coin 

cell battery.

The low battery level is no obstacle during normal clock operation. 

However, if the clock is not powered, it may result in loss of date and time 

settings.

All settings, except for time and date, are saved in non-volatile mem

-

ory and are not lost in the event of a power outage and low battery.

Under proper operating conditions, a new, charged battery is suffi

-

cient for approx. 6 years of operation. Low temperatures or long peri

-

ods of operation without AC power can shorten this period.

5.2. device error

Internal PCZ timer error indication. The error may be caused by external inter

-

ference, configuration error, or it may indicate a controller failure. 

If the message Err ... appears, turn off the power supply of the timer, wait about 

10 seconds and turn the power on again. If the error is repeated, please contact 

the service.

6. Configuration

The operation of the timer can be configured using the timer control panel and 

the configuration menu, or via the PCZ Konfigurator app for Android mobile 

devices equipped with NFC communication module.

6.1. data

Press MENU. The timer will enter program menu.

Using the 

+/–

 buttons select the date setting mode 

date

.

Confirm with 

ok

. Timer will show settings for the next parameters: year, month, 

and day. Use the 

+/–

 keys to set the parameters; move to the next parameter 

with the 

ok

 button. Go back to the previous item by pressing 

meNu

.

The day of the week is set automatically based on the year, month 

and day you entered.

Press 

ok

 to accept date setting. The timer will automatically exit from the date 

setting mode and go to the program menu

Choosing a date means that the correct time is also set at the same time: stand

-

ard (winter) or summer (daylight saving time).

The automatic time change can be turned off.

 

More information see section 6.7.1.

6.2. hour

Press 

meNu

. The timer will enter the program menu.

Using the 

+/–

 buttons select the mode for time setting 

hour

.

Confirm with 

ok

. Timer will show settings for the next parameters: hour and 

minutes. Set the parameters with the 

+/–

 buttons. Move to the next parameter 

with the 

ok

 button. Go back to the previous item by pressing 

meNu

.

Press 

ok

 to accept time entry. The timer will automatically exit from the date 

setting mode and go to the program menu.

6.3. operatioN modes

Press 

meNu

. The timer will enter program menu.

Using the 

+/–

 buttons select the mode for time setting 

mode

.

Select operation mode using the 

+/–

 buttons.

auto

 – automatic mode

haNd

 – manual mode

Press 

ok

 to accept. The timer will automatically exit from the date setting mode 

and go to the program menu.

6.4. locatioN

Setting the correct location of the timer is one of the key elements re

-

sponsible for the operation of the astronomical clock and the correct 

calculation of sunrise and sunset times.

Press 

meNu

. The timer will enter program menu.

Using the 

+/–

 buttons select the mode for time setting 

locate

.

ƒ

ƒ

list

 – select location from the list of coordinate codes,

ƒ

ƒ

user

 – manual setting of the user geographical position and time zone.

Press 

ok

 to accept

6.4.1. selectiNg a locatioN From the list

Check the table of coordinate codes located at the diagram of programming.

Find the country and the city closest to your location and the corresponding 

code.

The timer will enter country selection menu. Using the +/– buttons select the 

country. Accept by pressing OK. The timer will enter the coordinate code selec

-

tion. Using the +/– buttons select desired code from the list. Press OK.

The timer will automatically go to the location settings menu.

Pressing the 

meNu

 button will move you to a higher level.

After selecting a location from the list of locations, there is no need to 

write common geographical ordinates. The full list of locations (writ

-

ed in timer memory) you find from the product subpage on www.fif.

com.pl. Scan QR code below.

6.4.2. maNual locatioN settiNg

When you select a manual location setting, prepare the correct set of 

coordinates: latitude and longitude and the time zone related to UTC.

6.4.2.1. latitude

When the User option is selected (see 6.4), the timer will move to the latitude 

setting, where, using the 

+/–

 buttons, you will be able to sequentially set:

ƒ

ƒ

N – northern hemisphere;

ƒ

ƒ

S – southern hemisphere;

ƒ

ƒ

latitude in degrees and minutes of arc.

Switch to editing the next latitude element by pressing the 

ok

 button. Return to 

the previous position by pressing the 

meNu

 button.

Pressing the 

ok

 button after setting the minutes moves the program to the 

longitude setting.

6.4.2.2. loNgtitude

Ustawienie  długości  geograficznej  wprowadzenia  kolejno,  za  pomocą  przy

-

cisków 

+/–

 parametrów:

ƒ

ƒ

E – półkula wschodnia;

ƒ

ƒ

W – półkula zachodnia;

ƒ

ƒ

długość w stopniach i minutach kątowych.

6.4.2.3. time zoNe

Setting the selected time zone t is done with the 

+/–

 buttons. Large digits indi

-

cate hours, small digits – minutes. A single push of the button moves the zone 

by 30 minutes.

For Poland, set up a time zone +1

Confirm the location setting by pressing the 

ok

 button – the timer will automat

-

ically go to the 

locate

 menu. Pressing 

meNu

 will return to longitude editing.

6.5. program oN/oFF poiNts aNd Night break

The PCZ-525.3 Plus timer allows you to define 4 independent switch-on and 

switch-off points:

ƒ

ƒ

ON – controls the moment the light is switched on in the evening;

ƒ

ƒ

POFF – the beginning of the night break, which is the period in the middle of 

the night when the light is to be switched off;

ƒ

ƒ

PON – the end of the night break, which is the moment from which the light 

in the morning is to switch on again;

ƒ

ƒ

OFF – controls the moment the light is switched off in the morning.

The entered night interruption times are a permanent pair that exe

-

cutes switching on and off of the contact. They are treated as single 

commands and are executed according to the chronology of the set 

time.

6.5.1. switch oN

Press 

meNu

. The timer will enter program menu.

Using the 

+/–

 buttons select the mode for time setting 

oN.

Use the 

+/–

 buttons to select the correct moment of activation:

ƒ

ƒ

suNset

 – astronomical sunset

ƒ

ƒ

tlight

 – civil twilight

ƒ

ƒ

time

 – setting of the “rigid” hour of the switching on that is independentfrom 

the sunset

ƒ

ƒ

user

 – ustawienia użytkownika.

The switch-on time in the user settings is set as a shift of the switch-on point 

in relation to the sunset time. When selecting the 

user

 option, first of all, you 

should choose whether the switch-on time shift in relation to sunset will be 

expressed as time (ti) or as the angular position of the sun disc (°). Confirm the 

selected unit by pressing the OK button and then, using the 

+/–

 buttons, enter 

the numerical shift value (within ±180 minutes for the time shift or ±15° for the 

sun angle position shift).

Due to the different length of dawn/dusk depending on the season of 

the year and latitude, it is recommended to adjust the correction to 

the position of the center of the sun disc (°) to ensure switch-on/off 

at a similar brightness level.

Confirm selected setting by pressing the 

ok

 button, the timer will then return 

to display the 

oN

 menu.

When operating with the external light sensor switched on, the 

oN  

switch-on point is approximate, as the actual moment of switch-on 

will  depend  on  the  set  width  of  the  operating  zone  of  the 

tlight 

brightness sensor (6.6.3) and will be, depending on the brightness 

level (6.6.4 and 6.6.5), between (

oN

 – 

tlight

) and (

oN

 + 

tlight

).

6.5.2. poFF (begiNNiNg oF the Night break)

Press the 

meNu

 button. The clock will enter the program menu. Press the 

+/–

buttons to select the  

poFF

 setting.

Confirm your selection by pressing 

ok

. Use the 

+/–

 buttons to set the hour first 

and then the minute at which the night break should start. Confirm the edited 

value by pressing the 

ok

 button.

After confirming the minute, the clock will return to display the 

poFF

 menu. 

Return to the previously edited value by pressing the 

meNu

 button

Setting the beginning and end of the night break to the same time 

blocks  the  activation  of  the  night  break,  as  shown  in  the  diagram 

below:

PPZW – program points of switching on and off

PN – night break

6.5.3. poN (eNd oF the Night break)

Press the 

meNu

 button. The clock will enter the program menu. Press the 

+/–

buttons to select the  

poN

 setting.

Reviews: