background image

Limited Warranty: 

This product’s limited warranty can be 

found at www.fedsig.com/SSG-Warranty.

FT200C-V

Weather Resistant VoIP Hazardous Location 

Telephone

25500869 Rev A0 1123

SAFETY MESSAGES TO INSTALLERS AND USERS 

The equipment is not intended for repair by the user. Repair of this equipment shall be carried out by the manufacturer 

or manufacturer’s authorised agent.

It is the responsibility of the end user to take suitable precautions to prevent exposure to aggressive chemicals that 

may attack metals or the polymeric materials used in the construction of this equipment. Specific details of vulnerable 

materials shall be provided in the instructions.

• 

Read and understand instructions before installing or operating equipment. 

• 

Do not install this device near any heat sources such as radiators, heat registers, stoves, or other apparatus 

(including amplifiers) that produce heat.

• 

Only use attachments and accessories specified by the manufacturer.

• 

Refer all servicing to qualified service personnel.

• 

Prior to installation, consult local building and electrical code requirements.

• 

WARNING: ELECTRICAL HAZARD — 

This product should be installed by a licensed electrician according to all 

electrical and building codes.

• 

WARNING: HAZARDOUS AREA — 

Before opening the enclosure, ensure that the area is safe and that the power 

conductors are not live. When replacing the faceplate, ensure that the wires or other foreign objects are not trapped 

between the edges. Anything the prevents the base and the faceplate from being in direct contact nullifies the 

hazardous area rating of the telephone.

• 

WARNING: DISLOCATION HAZARD — 

To prevent injury, this apparatus must be securely attached to the floor or 

wall in accordance with the installation instructions.

• 

Suitable for use in class i, division 2, groups a, b, c and d hazardous locations or nonhazardous locations only.

• 

WARNING: EXPLOSION HAZARD — 

Do not disconnect equipment while the circuit is live or unless the area is 

known to be free of ignitable concentrations.

• 

WARNING: EXPLOSION HAZARD — 

Substitution of components may impair suitability for class I, division 2 

hazardous locations.

• 

WARNING: CHEMICAL HAZARD — 

Exposure to some chemicals may degrade the sealing properties of materials 

used in the sealed relay device.

Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or 

others.

Summary of Contents for FT200C-V

Page 1: ...ELECTRICAL HAZARD This product should be installed by a licensed electrician according to all electrical and building codes WARNING HAZARDOUS AREA Before opening the enclosure ensure that the area is...

Page 2: ...VALOX 357 engineering polymer Faceplate Steel corrosion protected and powder coated Dimensions H X W X D 12 X 9 6 X 3 9 inches 305 x 245 x 99 mm Net Weight Including Mounting Plate 7 lb 3 2 kg Shippin...

Page 3: ...lar parts for easy service Hearing Aid Compatible and Receiver Volume Adjustment Compatible with inductively coupled hearing aid devices Adaptive full duplex operation Compatible with most SIP based I...

Page 4: ...ning configuration file RTP Facilitates autoprovisioning configuration values on boot Audio Encodings PCMU G 711 mu law PCMA G 711 A law G722 1 Siren7 G722 2 AMR WB G729 1 G729J G729EV Supported SIP S...

Page 5: ...ircuit damage NOTES Follow all appropriate electrical codes and use only approved electrical fittings for the installation Determine if power to operate the telephone will be provided via the Ethernet...

Page 6: ...d To install the telephone 1 Separate the faceplate from the housing 2 Use the template provided or the enclosure itself to locate and drill holes for mounting screws 3 Secure the unit to the wall wit...

Page 7: ...ettings 12 Call to and from another telephone preferably a VoIP device to test the unit Operation The FT200C V telephone may be set up for either keypad dialing or auto dialing If the telephone is con...

Page 8: ...ctable through the web interface on the Device Configuration Page The relay can be controlled by DTMF tones generated from the monitoring phone to which the VoIP phone is connected or by other methods...

Page 9: ...egotiated baud rate This light is yellow at 10 Mbps It is orange at 100 Mbps Verify Network Activity The square yellow Activity light blinks when there is network activity Figure 8 Network Activity Re...

Page 10: ...n Page Field Repairs Field repairs must be carried out only by qualified technicians using OEM parts Substitution of parts voids the warranty and may pose a hazard to users of the equipment To make re...

Page 11: ...used to clean the telephone Pre moistened towelettes may also be used however avoid those containing lanolin or aloe as they will leave a slippery residue The handset and surface of the telephone may...

Page 12: ...rn authorization is required Contact your Authorized Distributor or Federal Signal Customer Support Defective products under warranty will be repaired or replaced at Federal Signal s discretion Produc...