background image

Limited Warranty: 

This product’s limited warranty can be found at www.fedsig.com/SSG-Warranty

SAFETY MESSAGES TO INSTALLERS AND USERS

 

: It is important to follow all instructions shipped with this 

product. This amplified speaker is to be installed by a trained electrician who is thoroughly familiar with and will follow 

all applicable national and local codes in the country of use.

This loudspeaker should be considered a part of the warning system and not the entire warning system.

The selection of the mounting location for the loudspeaker, its controls, and the routing of the wiring are to be 

accomplished under the direction of the facilities engineer and the safety engineer. Listed below are some other 

important safety instructions and precautions you should follow:

• 

Read and understand all instructions before installing or operating this equipment.

• 

To avoid electrical shock hazards, do not connect wires when power is applied. Failure to observe this warning may 

lead to serious injury or death.

• 

Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional openings or other 

alterations are made in units specifically designed for use in these locations.

• 

Do not connect this loudspeaker to the system when power is on.

• 

All effective warning speakers produce loud sounds, which may cause, in certain situations, permanent hearing 

loss. Take appropriate precautions such as hearing protection. The device should be installed far enough away 

from potential listeners to limit their exposure while still maintaining its effectiveness.

• 

After installation, ensure that all threaded joints are properly tightened.

• 

After installation, test the loudspeaker system to ensure that it is operating properly

• 

Keep the unit tightly closed when in operation.

• 

After testing is complete, provide a copy of this instruction sheet to all personnel.

• 

Brass inserts have the potential to store a charge when they are not plugged. Consideration should be taken to 

prevent these from becoming a sparking hazard.

• 

Establish a procedure to routinely check the loud speaker system for proper activation and operation.

• 

This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups F and G; Class 

III or non-hazardous locations only.

• 

WARNING - EXPLOSION HAZARD:

 Do not disconnect while the circuit is live or unless the area is known to be free 

of ignitable concentrations.

• 

WARNING - EXPLOSION HAZARD:

 Do not remove or replace the fuse when energized.

• 

The purchaser should make the manufacturer aware of any external effects or aggressive substances to which the 

equipment may be exposed.

Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or 

others.

With respect to the potential electrostatic charging hazard as mentioned in the certificate “Specific Conditions of Use,” 

under normal conditions of use, these devices are for fixed installations and not generally in contact with people. 

The risk of ignition is low. In addition, maintenance, cleaning, and extreme environmental factors (e.g., high velocity 

dust-laden atmospheres or high-pressure steam) should be taken into account by the end user using local Explosive 

Atmosphere (Ex) Electrical installation design, selection, inspection, and maintenance Codes and Standards. Cleaning of 

the devices should be done only with a damp cloth.

Global Series Model G-SPK  

Loudspeaker for Use in Hazardous Conditions

25500189 Rev B7 0523

Summary of Contents for Global Series

Page 1: ...tightened After installation test the loudspeaker system to ensure that it is operating properly Keep the unit tightly closed when in operation After testing is complete provide a copy of this instruc...

Page 2: ...equipment is for use in Class I Zone 1 and Zone 21 hazardous classified locations It has been investigated with reference to risks to life and property and for conformity to the installation and use...

Page 3: ...apparatus must be securely attached to the mounting surface in accordance with the installation instructions Use installer supplied fasteners suitable for the mounting surface The mounting method and...

Page 4: ...ing the six 8 5 mm mounting holes Use installer supplied fasteners suitable for the surface to which the device will be mounted Figure 3 Front view of Ex de surface mount 2X 8 5 mm 103 2 mm 4 06 in 12...

Page 5: ...or reassembling the unit Painting and surface finishes other than those applied by Federal Signal Corporation are not permitted Cable termination should be in accordance with the specifications that...

Page 6: ...the application Gland entry threads are M20 1 5 x 6 H Tools needed 1 5 mm A F hexagon key No 1 Phillips screwdriver Wire stripper Figure 5 Ex d in out PCB connections 2 8 V 0 8 VRMS 1 2 3 4 Wiring th...

Page 7: ...y or death This section has wiring instructions for the increased safety models G SPK 70 V and 100 V Ex de units are supplied with a six pole spring tension clamp style terminal block The maximum wire...

Page 8: ...intaining the Loudspeaker SAFETY MESSAGES TO MAINTENANCE PERSONNEL Listed below are some important safety instructions and precautions you should follow Read and understand all instructions before ope...

Page 9: ...is as resistant to concentrated acids and alkalis as most metal products However if abnormal or unusual environment conditions occur due to plant damage or accident etc visual inspection of the louds...

Page 10: ...ervice A return authorization is required Contact your Authorized Distributor or Federal Signal Customer Support Defective products under warranty will be repaired or replaced at Federal Signal s disc...

Page 11: ...ion Box Spacer Kit G KIT EXTB Single Trunnion Kit G KIT ST Dual Trunnion Kit G KIT DT Adapter M20 Male to 1 2 Female NPT K231246A Adapter M20 Male to 3 4 Female NPT K231247 15 W Audible Acoustic Inser...

Page 12: ...ranslations available at signaling fedsig com Traducciones adicionales disponibles en signaling fedsig com Customer Support 1 800 344 4634 1 708 534 4756 iordersup fedsig com Technical Support 1 800 7...

Reviews: