background image

MONTAGE

INSTALLATION

final
public (B)
2003-11-18
M30800-1de-ID-B.doc

OBID

®

 

classic-pro

ID CPR.02.VP/AB-A 

(RS232 Interface)

ID CPR.02.VP/AB-B 

(RS485 Interface)

(deutsch / english)

Summary of Contents for OBID classic-pro ID CPR.02.VP/AB Series

Page 1: ...MONTAGE INSTALLATION final public B 2003 11 18 M30800 1de ID B doc OBID classic pro ID CPR 02 VP AB A RS232 Interface ID CPR 02 VP AB B RS485 Interface deutsch english...

Page 2: ...OBID classic pro Montage ID CPR 02 VP AB x FEIG ELECTRONIC GmbH Seite 2 von 36 M30800 1de ID B doc D E U T S C H deutsche Version ab Seite 2 english version from page 2 E N G L I S H...

Page 3: ...NIC GmbH nicht f r Folgesch den auf Grund fehlerhafter oder unvollst ndiger Angaben haftbar gemacht werden Da sich Fehler trotz aller Bem hungen nie vollst ndig vermeiden lassen sind wir f r Hinweise...

Page 4: ...Spannungsversorgung 11 3 3 Relais ID CPR 02 VP AB B 11 3 4 Digitale Eing nge 11 3 5 RS232 Schnittstelle ID CPR 02 VP AB A 11 3 6 RS485 Schnittstelle ID CPR 02 VP AB B 12 3 6 1 Adresseinstellung Busbe...

Page 5: ...ete falsche manuelle oder au tomatische Einstellung von Parametern f r ein Ger t bzw ungeeignete Verwendung ei nes Ger tes wird keine Haftung bernommen Reparaturen d rfen nur vom Hersteller durchgef h...

Page 6: ...erte Oberfl chen montiert werden da diese Fl chen eine Redu zierung der Lesereichweite bewirken Der Abstand zu derartigen Fl chen sollte mindes tens 3 cm betragen Ist eine Montage auf einer Metallober...

Page 7: ...il stecken Dabei die Stiftleiste der Leserelektronik sau ber in Buchsenleiste X3 einf hren Funktionskontrolle 4 Wandmontage Geh useoberteil von Unterteil abziehen Geh useunterteil mit eingerasteter An...

Page 8: ...schlie en Anschlussplatine 1 gem Abbildung 3 mit den Anschlussklemmen nach unten in das Ge h useunterteil einrasten Dazu die Rasthaken mit den Fingern leicht auseinanderdr cken Geh useoberteil auf Ge...

Page 9: ...rd Abbildung 4 Anschlussplatine Klemme Funktion Leiste Bezeichnung ID CPR 02 VP AB A ID CPR 02 VP AB B Spannungsversorgung 12 24 AC DC CLS Daten Taktschnittstelle CLS COM NO Digitaler Eingang 3 Relais...

Page 10: ...P AB Die Jumper und Schalter sind nur bei demontiertem Ger t zug nglich 1 2 3 4 5 6 7 8 ON OFF X7 1 J1 J2 X1 S1 3 2 1 X4 X3 X2 Abbildung 5 Jumper und Schalter S1 DIP Schalter zur Einstellung der Leser...

Page 11: ...gt werden 3 3 Relais ID CPR 02 VP AB B Der Leser verf gt ber ein Relais mit einem Schlie erkontakt Der Anschluss erfolgt ber die Klemmen NO und COM 3 4 Digitale Eing nge Die digitalen Eing nge IN1 IN2...

Page 12: ...ng 5 Der Busbetrieb setzt einen Leitrechner mit Abschlusswiderstand und aktiver Terminierung voraus Als Leitung wird eine paarweise verseilte oder verdrillte Leitung empfohlen Host mit aktiver Termini...

Page 13: ...folgt mittels der DIP Schalter S1 DIP1 DIP4 ge m Tabelle DIP5 DIP8 haben keine Funktion Dabei wird jeder Leser mit einer indivi duellen Adresse versehen Adresse DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF O...

Page 14: ...Daten Taktschnittstelle ID CPR 02 VP AB A Der Anschluss der Daten Taktschnittstelle erfolgt gem Abbildung 11 Falls am Host kein CLS An schluss vorgesehen oder notwendig ist kann auf diese Leitung ver...

Page 15: ...mifare mifare Ultra Light my d proximity ISO14443 B kompatibel ISO15693 kompatibel z B I Code SLI Tag It HFI my d vicintiy STM LRI512 I Code 1 LED Bicolor rot gr n orange Summer integriert Relais 1 x...

Page 16: ...OBID classic pro Montage ID CPR 02 VP AB x FEIG ELECTRONIC GmbH Seite 16 von 36 M30800 1de ID B doc D E U T S C H 4 1 Abmessungen Unterputzmontage Abbildung 12 Abmessungen Unterputzgeh use A Unten...

Page 17: ...ic pro Montage ID CPR 02 VP AB x FEIG ELECTRONIC GmbH Seite 17 von 36 M30800 1de ID B doc 4 2 Abmessungen mit ID APR A bei Aufputzmontage Abbildung 13 Abmessungen bei Montage mit Aufputzrahmen ID APR...

Page 18: ...om M rz 99 Equipment Classification gem ETSI EN 300 330 und ETSI EN 301 489 Class 2 4 3 2 USA FCC FCC ID PJMCPR02 This device complies with Part 15 of the FCC Rules Operation is subject to the followi...

Page 19: ...useoberteil mit Leserelektronik 1 x Anschlussplatine 1 x Frontaufkleber 1 x Schneidschraube 3 2 x 25 mm zur Verbindung der Geh useteile 2 x Schneidschrauben 3 2 x 15 mm zur Wandmontage 1 x Montageanl...

Page 20: ...this manual and may not be held liable for damages ensuing from incorrect or incomplete information Since despite all our efforts errors may not be completely avoided we are always grateful for your...

Page 21: ...Jumper and Switches 27 3 2 Power supply 28 3 3 Relay ID CPR 02 VP AB B 28 3 4 Digital inputs 28 3 5 RS232 Interface ID CPR 02 VP AB A 28 3 6 RS485 Interface ID CPR 02 VP AB B 29 3 6 1 Address setting...

Page 22: ...rescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufacturer is not legally responsible for incorrect unsuitable manual or automatical setting...

Page 23: ...e g metal sur faces metal grids reinforcements or metallized surfaces as these surfaces reduce the detection range of the Reader The distance between the Reader and such surfaces should be min 3 cm If...

Page 24: ...nto its bottom part The pin board of the Reader electronic has to be inserted carefully into the socket board X3 Function test 4 Wall installation Remove top of the casing from its bottom part Screw b...

Page 25: ...pter Reader connection 3 Close casing Snap in connection board 1 to bottom part of casing according to Fig 3 with the connectors in downward direction In order to do this press the notches slightly ap...

Page 26: ...part of the casing Fig 4 Connection board connector function board name ID CPR 02 VP AB A ID CPR 02 VP AB B power supply 12 24 AC DC CLS data clock interface CLS COM NO digital input 3 relay GND inte...

Page 27: ...the ID CPR 02 The jumpers and switches are only accessible at the opened device 1 2 3 4 5 6 7 8 ON OFF X7 1 J1 J2 X1 S1 3 2 1 X4 X3 X2 Fig 5 Jumper and Switches S1 DIP switch to configure the Reader...

Page 28: ...d low voltage wires 3 3 Relay ID CPR 02 VP AB B The device is equipped with an relay normally open contact The connection is executed via the connectors NO and COM 3 4 Digital inputs The digital input...

Page 29: ...nal X2 see Fig 8 and Fig 5 To operate the bus you need a host computer with a terminating resistor and active termination A twisted paired or stranded wire is recommended without termination R A T B R...

Page 30: ...uted via the DIP switches S1 DIP1 DIP 4 according to the table seen below DIP5 DIP8 are unused Thus each Reader is being provided with an individual address Address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF O...

Page 31: ...ID B doc 3 7 Data Clock interface ID CPR 02 VP AB A The connection of the data clock interface is executed according to Fig 11 If no CLS signal is required on host this connection can be abandon Fig...

Page 32: ...ble e g mifare mifare Ultra Light my d proximity ISO14443 B compatible ISO15693 compatible e g I Code SLI Tag It HFI my d vicinity STM LRI512 I Code 1 LED bicolor red green orange Buzzer integrated Re...

Page 33: ...OBID classic pro Installation ID CPR 02 VP AB x FEIG ELECTRONIC GmbH Page 33 of 36 M30800 1de ID B doc 4 1 Dimensions for concealed installation Fig 12 Dimensions of concealed casing A below...

Page 34: ...ro Installation ID CPR 02 VP AB x FEIG ELECTRONIC GmbH Page 34 of 36 M30800 1de ID B doc 4 2 Dimensions for surface installation with ID APR A Fig 13 Dimensions for installation with surface frame ID...

Page 35: ...Classification according to ETSI EN 300 330 and ETSI EN 301 489 Class 2 4 3 2 USA FCC FCC ID PJMCPR02 This device complies with Part 15 of the FCC Rules Operation is subject to the following two condi...

Page 36: ...casing with Reader electronic 1 x connection board 1 x adhesive label 1 x thread cutting screw 3 2 x 25 mm for connecting parts of casing 2 x thread cutting screws 3 2 x 15 mm for wall installation 1...

Reviews: