background image

MONTAGE

INSTALLATION

final
public (B)
2003-06-10
M30500-0de-ID-B.doc

OBID i-

scan

®

ID ISC.PRH110-A

(deutsch / english)

Summary of Contents for OBID i-scan ID ISC.PRH110-A

Page 1: ...MONTAGE INSTALLATION final public B 2003 06 10 M30500 0de ID B doc OBID i scan ID ISC PRH110 A deutsch english...

Page 2: ...OBID i scan Montage ID ISC PRH110 A FEIG ELECTRONIC GmbH Seite 2 von 24 M30500 0de ID B doc D E U T S C H deutsche Version ab Seite 2 english version from page 2 E N G L I S H...

Page 3: ...issen FEIG ELECTRONIC GmbH bernimmt keine Gew hrleistung f r die Richtigkeit und Vollst ndigkeit der gemachten Angaben Insbesondere kann FEIG ELECTRONIC GmbH nicht f r Folgesch den aufgrund fehlerhaft...

Page 4: ...n 5 2 Leistungsmerkmale und Varianten des Readers ID ISC PRH110 A 6 2 1 Leistungsmerkmale 6 2 2 Verf gbare Readertypen der Produktfamilie ID ISC PRH 6 3 Montage und Anschluss 7 3 1 Asynchrone Schnitts...

Page 5: ...in der zum Zeitpunkt des Kaufs g ltigen Fassung F r eine ungeeignete falsche manuelle oder automatische Ein stellung von Parametern f r ein Ger t bzw ungeeignete Verwendung eines Ger tes wird kei ne...

Page 6: ...eb ausgelegt Eine Anticollision Funktion erm glicht das gleichzeitige Lesen von mehreren Transpondern Die Elektronik des Readers befindet sich in einem handlichen Kunststoffgeh use mit der Schutz art...

Page 7: ...232 Der Anschluss der RS232 Schnittstelle erfolgt ber die 9 polige D Sub Buchse Die bertragungsparameter k nnen per Softwareprotokoll konfiguriert werden Anschlussbelegung der 9 poligen D Sub Buchse R...

Page 8: ...der Deckel entfernt Die Batte rien sind gem der im Geh usegriff eingepr gten Symbole einzusetzen Es ist auf die Polung zu achten Danach wird der Deckel wieder eingesetzt und die Feder h rbar einraste...

Page 9: ...LABEL Leuchtet wenn ein Transponder erkannt wird LED orange INITIALISIERUNG Blinkt w hrend der Reader Initialisierung nach dem Einschal ten Tabelle 4 1 Standard Konfiguration der LED 4 2 Summer Der Su...

Page 10: ...20 g ohne Batterien Schutzart IP 30 Kabell nge 2 5 m Farbe RAL 9002 Elektrische Daten Spannungsversorgung 4 Mignon Zellen nicht im Lieferumfang enthalten Leistungsaufnahme max 3 0 VA Betriebsfrequenz...

Page 11: ...oc D E U T S C H Umgebungsbedingungen Temperaturbereich Betrieb Lagerung 0 C bis 50 C 20 C bis 70 C Relative Luftfeuchtigkeit 5 bis 95 nicht betauend Normenkonformit t Zulassung Funk Europa USA EN 300...

Page 12: ...rmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Unauthorized modifications may void the authority granted under Fed...

Page 13: ...OBID i scan Montage ID ISC PRH110 A FEIG ELECTRONIC GmbH Seite 13 von 24 M30500 0de ID B doc D E U T S C H...

Page 14: ...one to the best of our knowledge FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorr...

Page 15: ...ce features and variants of the ID ISC PRH110 A Reader 17 2 1 Performance features 17 2 2 Available Reader types from the ID ISC PRH product family 17 3 Installation and Connection 18 3 1 RS232 asynch...

Page 16: ...e issue valid at the time of purchase are valid for the device The manufacturer is not legally responsible for incorrect unsuitable manual or automatical setting of parameters for a device or the inco...

Page 17: ...for manual operation An anti collision function allows simultaneous reading of multiple transponders The Reader electronics is contained in a handy plastic enclosure having an IP30 rating The Reader...

Page 18: ...chronous interface The RS232 interface uses a 9 pin D Sub female connector The transmission parameters can be configured using software protocol Pin assignments for the 9 pin D Sub female connector RS...

Page 19: ...out with your fingernail to remove the cover Insert the batteries as indicated by the symbols stamped in the handle Observe proper polarity Then replace the cover and latch the spring listen for a cli...

Page 20: ...o run LED red LABEL Comes on when a transponder is detected LED orange INITIALIZATION Flashes during Reader initialisation after power is turned on Table 4 1 Standard configuration of the LEDs 4 2 Buz...

Page 21: ...without batteries Enclosure rating IP 30 Cable length 8 2 2 5 m Color RAL 9002 Electrical Data Supply voltage 4 Mignon cells not included in delivery Power consumption max 3 0 VA Operating frequency 1...

Page 22: ...G L I S H Ambient conditions Temperature range Operation Storage 0 C to 50 C 20 C to 70 C Humidity 5 95 non condensing Standard conformity Radio approval Europe USA EN 300 330 FCC 47 CFR Part 15 EMC E...

Page 23: ...e harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Unauthorized modifications may void the authority granted under...

Page 24: ...OBID i scan Installation ID ISC PRH110 A FEIG ELECTRONIC GmbH Page 24 of 24 M30500 0de ID B doc E N G L I S H...

Reviews: