background image

User Manual: FX500 | A | IP | IPA 

Summary of Contents for FX500

Page 1: ...User Manual FX500 A IP IPA...

Page 2: ......

Page 3: ...Measurements 7 3 INSTALLATION Installation requirements 8 Connecting the DMX signal cable 9 3 pin zu 5 pin transition table 9 4 INSTRUCTIONS Control panel functions 10 Menu folder 11 Settings 12 Form...

Page 4: ...the original packaging in case of returns POWER SUPPLY Mains voltage AC 100 240V 50 60 Hz The appliance is equipped with an automatic switch mode power supply Please check before initial operation th...

Page 5: ...e must be switched off when not in use or before approval The cable must be plugged in to the socket and unplugged by hand Be careful when installing the appliance To avoid electric shock never ever t...

Page 6: ...65 outdoor version Product size 990x120x145 mm Packaging size 1070x160x170 mm Weight 5 70 kg FEATURES RGBW or RGBA colour mixing 5 individual dimmer curves User defined programs LED display with passw...

Page 7: ...old separately DMX IN DMXOUT DMX IN DMXOUT DMX IN DMXOUT Power in voltage input DMX in DMX input LED signal pilot light Power out voltage output DMX out DMX output MEASUREMENTS POWER IN POWER IN DMX O...

Page 8: ...lammable objects may be placed within a half meter radius of the appliance To avoid damage to the appliance mounting and installation of the appliance should be handled by a qualified professional Reg...

Page 9: ...t in a row we recommend using FEIMEX Platin DMX cables The DMX signal does not detoriate An supplemental signal amplifier is not necessary DMX IN DMXOUT DMX IN DMXOUT DMX IN DMXOUT 3 PIN ZU 5 PIN TRAN...

Page 10: ...NTER To select the currently shown menu or to define the currently selected value in the selected function UP Navigates up in the menu bar and increases the numeric value within a function DOWN Naviga...

Page 11: ...selectable auto programs with speed steps from 00 20 available AP00 SP00 20 Combined auto programs CP00 SP00 20 Combined cartoon effects SLAV SLA Slaves PERS 11CH Selection of operation modes 04CH 06C...

Page 12: ...gate between the menu options AT00 AP00 or CP00 with UP DOWN and select the desired program Confirm your selection with ENTER 2 3 Press MENU to return to menu 2 4 The fixture in slave mode connected b...

Page 13: ...em and confirm ENTER 3 3 Select the desired dimmer curve with UP DOWN and confirm with ENTER 3 4 Press MENU to return to menu 4 Fixture locking 4 1 Repeatedly press MENU until KEY ist shown and confir...

Page 14: ...d fixtures on the display must not be higher than the actual number of fixtures in use Selecting the master fixture 1 1 Press MENU until auto is shown and confirm with ENTER 1 2 Chose between the menu...

Page 15: ...176 191 B W 192 207 R G W 208 223 G B W 224 239 R G B 240 255 R G B W 4 000 005 No function 006 255 Strobe 0 to 20 Hz 5 000 005 No function 006 255 Auto program AP 1 50 6 000 009 No function 010 255 A...

Page 16: ...the menu item 2 2 Press ENTER to switch between colours and strobe 2 3 Increase or decrease the VALUE of the selected colour by chosing between 000 and 255 with UP DOWN 2 4 Press ENTER to go to the ne...

Page 17: ...auto program 1 50 If an auto program is activated auto speed can be varied with channel 10 Channel 9 has priority over channels 2 to 8 Channel 5 has priority over channels 2 to 6 Channel 6 has priori...

Page 18: ...ogram FUNCTION is activated auto speed is regulated with channel 5 15 Channels Channel Value Description 1 LED 1 2 LED 2 3 LED 3 4 LED 4 5 LED 5 6 LED 6 7 LED 7 8 LED 8 9 LED 9 10 LED 10 11 LED 11 12...

Page 19: ...on 006 255 Macro colour control 7 Strobe 000 255 Strobe 0 to 20 Hz 8 Module Selection 000 004 1 ON 2 ON 3 ON 005 034 1 ON 035 064 2 ON 065 094 3 ON 095 124 1 ON 2 ON 125 154 1 ON 3 ON 155 184 2 ON 3 O...

Page 20: ...1 12 LED 12 13 LED 13 14 LED 14 15 LED 15 000 015 No function 016 031 R 032 047 G 048 063 B 064 079 R G 080 095 G B 096 111 R B 112 127 R G B 128 143 W 144 159 R W 160 175 G W 176 191 B W 192 207 R G...

Page 21: ...96 111 R B 112 127 R G B 128 143 W 144 159 R W 160 175 G W 176 191 B W 192 207 R G W 208 223 G B W 224 239 R B W 240 255 R R B W 16 Module 1 17 Module 2 18 Module 3 000 005 No function 006 255 Strobe...

Page 22: ...green blue and white colour selection Channels 2 3 4 and 5 control the degree of intensity of the red green blue and white LEDs Channels 1 2 3 4 and 5 can be used in combination Colour macros The requ...

Page 23: ...sired step and transition time with channels 2 and 3 Channel 8 has priority over channels 2 7 Dimmer speed Channel 10 is for selecting the dimmer mode and dimmer speed If channel 10 is not used RGBW a...

Page 24: ...t LED PCB directly from your dealer The fuse swit ches off the fuse blows Check the total load of the voltage circuit Check whether an internal or external short circuit has occurred in the cabling Th...

Page 25: ...onnection to the appliance is in order This appliance must be operated in the correct mode to have CONTACT with the COLOR CON controller The correct MODE on the integrated control panel is SLAVE Stand...

Page 26: ...ave control Stroboscope 0 20 Hz Dimmer 0 100 Operation LCD display DMX 512 connection Neutrik XLR 3 pole male female Specifications Mains voltage AC 100 240 V Power consumption 105 W Connection FX500...

Page 27: ...CONTACT FEIMEX Ltd Unit 701 The Workstation 43 Lyndhurst Terrace Central Hong Kong T 49 0 40 468 991 790 office feimex com www feimex com...

Reviews: