ELECTRIC ONLY HEATING WALL BOILER 

 

series 

Elektra Compact.. 

N 6-7-8-9-12-15-18 kW

 

 

 

 

 
 
 
 
 
 
 

 
 
 
 
 

 

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

USER AND MAINTENANCE MANUAL 

 

 

 

 

EQUIPMENT CONFORM 

7

O IEC 60335-

2

 

$$

IEC 60335-

$

 

EN 60335-

:2

+ A

1:20

+

A

:20

 

$$$DQG

(1

 

$$

Summary of Contents for Silver Touch Elektra Compact 12 kW N

Page 1: ... ELECTRIC ONLY HEATING WALL BOILER series Elektra Compact N 6 7 8 9 12 15 18 kW USER AND MAINTENANCE MANUAL EQUIPMENT CONFORM 7O IEC 60335 2 IEC 60335 EN 60335 2 A 1 20 A 20 DQG 1 ...

Page 2: ......

Page 3: ...nd economy functioning in order to reduce power consumption when the device is not used at the maximum capacity or demand the appliance is fully adjustable both in water temperature of the heating system with the possibility to choice of system at high and low temperature forthe underfloor systems and in the domestic hot water temperature The assembly of the components has been realized in order t...

Page 4: ...S DISCONNECTION WITH A CONTACT OPENING DISTANCE THAT ALLOWS COMPLETE DISCONNECTION UNDER THE CONDITIONS OF OVERVOLTAGE CATEGORY III IN ACCORDANCE WITH THE INSTALLATION RULES IN ORDER TO PREVENT ANY RISKS DAMAGED POWER SUPPLY CABLES MUST BE REPLACED BY THE MANUFACTURER OR ITS TECHNICAL SUPPORT SERVICE OR BY SOMEONE WITH SIMILAR QUALIFICATIONS WATER MAY DRIP FROM THE OVERPRESSURE DRAIN PIPE OF THE A...

Page 5: ... maximum electric power Elektra Compact 7 kW N 7 kW maximum electric power Elektra Compact 8 kW N 8 kW maximum electric power Elektra Compact 9 kW N 9 kW maximum electric power Elektra Compact 12 kW N 12 kW maximum electric power Elektra Compact 15 kW N 15 kW maximum electric power Elektra Compact 18 kW N 18 kW maximum electric power Appliance Packing dimensions W Width 400 mm Width 440 mm H Heigh...

Page 6: ... R Central Heating Return M VSR Central Heating Safety Valve 0 3 MPa 3 bar F The appliance is designed to be continuously connected to the water mains without intermediate fittings View from below under the boiler R M VSR Allacciamenti elettrici Electrical supply Electric power supply ...

Page 7: ...om no 2 heating elements no 1 of 3x2 kW and no 1 of 3x1 kW Maximum head available to the circulator approx 7 m Expansion vessel capacity 9 litres 0 3 MPa 3 bar central heating circuit safety valve Maximum central heating operating pressure 0 25 MPa 2 5 bar Minimum central heating circuit operating pressure 0 06 MPa 0 6 bar Central heating circuit boiler body maximum thermal safety limit 100 C Elek...

Page 8: ... heating circuit operating pressure 0 06 MPa 0 6 bar Central heating circuit boiler body maximum thermal safety limit 100 C Elektra Compact 18 kW N 18 kW maximum electric power Single phase power supply 230 240 V 50 Hz Weight 40 kg Central heating system 18 kW electric thermal power from no 3 heating elements no 3 of 3x2 kW Maximum head available to the circulator approx 7 m Expansion vessel capac...

Page 9: ...ate plugs for the type of wall not supplied with the boiler The appliance must be attached to the top of the bracket inserting the bent section of the same through the boiler frame at the back CONTROL PANEL 0 1 2 3 4 5 6 bar The control panel consisting of the display screen the function selection keys the illuminated main switch and the hydrometer can be found at the bottom left of the front of t...

Page 10: ...tatus bar shows CH Set and both the temperature setpoint value and the icon will flash for 5 seconds SW2 Can be used to decrease the central heating system temperature setpoint the status bar shows CH Set and both the temperature setpoint value and the icon will flash for 5 seconds If the board is set to manage two separate zones at the end of the 5 seconds the status bar shows CH Set 2 at which m...

Page 11: ...pressure reading The analogue hydrometer on the control panel has a bar dial from 0 to 6 bar The current central heating system water pressure is indicated by the black needle The optimum central heating system water pressure is between 1 and 1 5 bar The pressure can exceed 1 5 bar to a maximum of 2 bar maximum expansion of the system during a temperature rise Pressures over 2 bar are not within t...

Page 12: ...top shows the operating status of the boiler or in case of fault the fault code The table below shows all the possible status bar messages STATUS DISPLAY DESCRIPTION STANDBY No heat request received by the boiler ANTI FREEZE STATUS Anti freeze active COMFORT MODE Comfort mode active HEATING STATUS Heating active ANTI LEGIONELLA Anti legionella active SANITARY WATER STATUS Sanitary water active OFF...

Page 13: ...E probe is enabled parameter menu idx 001 val 001 it is also possible to set the room temperature setpoint The screen will show the symbol instead of the symbol and the room temperature setpoint instead of the central heating system delivery temperature At the centre is a graduated bar that shows the operating power of the boiler In case of heating request the icon appears at the side of the bar T...

Page 14: ...selected in the main screen the temperature detected by the delivery probe disappears and is replaced with the sun icon see screen below If OFF mode is selected the display shows the following If the boiler is connected to a WiFi network the following icons appear The graduated bar indicates the quality of the WiFi signal 3 bars very good 2 bars medium 1 bar poor In the event of WiFi network or in...

Page 15: ...er or SW3 ESC to return to the main screen or SW5 OK to access the Info Boiler menu The table below describes the hierarchical system of the SETTINGS MENU SETTINGS MENU Info boiler Setting boiler Installer menu Factory menu Device menu Faults history Degasser Boiler SW version Special functions Setting Display Language Time setting Contrast Brightness Touch sensitivity Factory reset Data monitor S...

Page 16: ...ected by the external probe SE Th Room Room thermostat TA status ON Closed OFF Open 2 Th Safety Safety thermostat TS status ON Closed OFF Open OpenTherm OpenTherm communication status ON Active OFF Not active RS 485 RS485 communication status cascade ON Active OFF Not active Press H2O Water pressure switch status if present ON Closed OFF Open If transducer present PRESSURE TRANSDUCER VALUE 3 Flow ...

Page 17: ...ower in kW of triac number 1 4 Gate 2 Power in kW of triac number 2 Gate 3 Power in kW of triac number 3 Gate 4 Power in kW of triac number 4 Gate 5 Power in kW of triac number 5 5 Gate 6 Power in kW of triac number 6 Gate 7 Power in kW of triac number 7 Gate 8 Power in kW of triac number 8 Gate 9 Power in kW of triac number 9 6 Gate 10 Power in kW of triac number 10 Gate S Power in kW of triac S ...

Page 18: ...ows the Read parameter screen where the parameter index is shown on the left and its current value on the right The value does not appear instantaneously but is transferred each time from the control board of the boiler Before its appearance three dashes will be displayed for a few moments Press SW6 and SW7 to scroll through the entire list of parameters Press SW5 SET to access the parameter edit ...

Page 19: ... If there are no faults the following screen is displayed In case of fault or lockout the above screen is updated as follows Where ID Index ID of the fault occurred Fault F fault or lockout code Faults are indexed in succession starting with ID 001 Each time there is a new fault the previous ones are moved upwards up to a maximum of 10 After that every time there is a new fault the oldest one is d...

Page 20: ... this function is active a timer appears on the display to indicate the time required to complete the function Under Boiler version it is possible to view the version of the software loaded on the boiler control board The last item Special functions is password protected and is used to activate the boiler demo mode During demo mode fictitious information is shown on the display so that for example...

Page 21: ...communication between the display and the board of the boiler In the Brightness option it is possible to set the maximum intensity and also the minimum idle intensity which activates when the display remains inactive for one minute The parameters set in the Setting Display menu are stored in the memory and are preserved in case of power failure To restore the factory default values simply go to Fa...

Page 22: ...network connection procedure set the data transfer rate Server rate display the MAC address of the WiFi module and the IP address assigned by the network The first time it is accessed the Setting WiFi screen looks as shown below Touch the SW5 OK key and the SW6 SW7 keys followed by SW5 OK again to activate the WiFi connection The following additional items will be added to the screen The second ro...

Page 23: ...hronowifi com 4 Touch the Refresh button in the Detect device section to update the networks detected by your smartphone 5 When you select the network in the Detect Device section it will appear in the Network Name window 6 Enter the password in the Pass phrase box Enter a name of your choice in the Device Name box Touch Connect button to initiate the connection 7 The display screen of the boiler ...

Page 24: ...etworks are supported To optimize its operation it is recommended to install the boiler where the detected signal is at least 60dBm The password entered when using the SCAN method must not exceed 40 characters When using the smartphone connection method PROV only networks with OPEN or WPA personal security may be connected Moreover the smartphone connection method PROV only allows one device at th...

Page 25: ...us switches to WIFI CONNECTED and the boiler is ready to accept changes through the smartphone app WIFI DEVICE indicates that the smartphone is changing parameters on the boiler One minute after the last change made through the smartphone application the status switches to WIFI CONNECTED and the boiler is ready to accept new changes including from a different smartphone 2 The second row shows if t...

Page 26: ... of the boiler Id f8f005xxxxxxxx and the password in order to connect The same password may be required by technical support if the user wishes to use the remote technical support service In this case the user gives to technical support the MAC address of the boiler and the password in order to allow them to connect remotely and check the operation and any faults The last Option Download certs all...

Page 27: ...ay of the week to program A reminder of the corresponding daily program is shown underneath Taking Monday as an example touch SW5 OK to enter time band programming The time bands are programmed in three steps 1 Time band start to select band start time 2 Request to set the heat request 3 Time band end to select the band end time In the first step enter the start time using the SW7 and SW6 keys wit...

Page 28: ... to copy a program of one day to another day by selecting the source day from which to copy at the top and the destination day to which to copy at the bottom To set the same program for every day simply select ALL When the SW5 OK button is pressed a message confirms that the program has been copied The last entry of the menu Show program allows to activate the weekly program and display some infor...

Page 29: ...as well as the age of the electronic components For the power reserve to be fully operational the device must have been correctly and continuously powered for at least two hours STORING DATA IN THE MEMORY If even the internal power reserve described in the above paragraph is exhausted the display still saves some settings and data in the memory display settings WiFi settings weekly program and fau...

Page 30: ...y to reset the display with the Reset button on the back INSTALLATION WARNINGS Observe the applicable national and European standards e g EN60335 1 prEN50165 relating to electrical safety Check the cables carefully before putting the boiler into operation incorrect wiring can damage the devices and compromise the safety of the system Enable and disable the control system only when there is no volt...

Page 31: ...ucer 8 Safety valve 3 bar central heating 9 Exhaust tap air vent 10 Variable head circulator 11 Automatic vent valve R Central heating system return M Central heating system delivery As far as the other models the only differences are in the number of electric heating elements the 6 kW version has two 3 kW heating elements the 7 8 9 kW version has one 6 kW heating element and one 3 kW heating elem...

Page 32: ...45 44 43 42 41 40 38 37 36 55 56 54 J11 Interface 961 O2 JP7 JP8 JP9 JP10 0 1 39 1 2 3 1 2 3 4 5 6 7 J14 J12 J11 J5 J6 N FT G3 G2 G1 G4 53 F E PWM white yellow red blue brown black black brown brown blue red blue red brown white white black 1 4 grey yellow brown green WIRING DIAGRAM single phase red brown brown brown blue red brown brown brown black ...

Page 33: ...ctioned phase FT Pump PI Gate command triac no 1 12 kW version 4 kW load G1 Gate command triac no 2 12 kW version 2 kW load G2 Gate command triac no 3 12 kW version 4 kW load G3 Gate command triac no 4 12 kW version 2 kW load G4 Delivery probe SM External probe SE Pressure transducer TP Safety thermostat TS Room thermostat prearranged terminals TA Main switch also disconnects the board ON OFF Func...

Page 34: ...2 1 kW NERO sez 2 5 mm 2 TRIAC 3 2 kW NERO sez 2 5 mm 2 TRIAC 4 1 kW NERO sez 2 5 mm 2 TRIAC 1 2 kW NERO sez 2 5 mm 2 GATE G2 BIANCO da p to 6 spinotto J5 GATE G3 NERO da p to 7 spinotto J5 GATE G4 ROSSO da p to 2 spinotto J5 GATE G1 GIALLO da p to 5 spinotto J5 TRIAC 2 1 2 kW NERO sez 2 5 mm 2 TRIAC 3 2 kW NERO sez 2 5 mm 2 TRIAC 4 2 kW NERO sez 2 5 mm 2 TRIAC 1 2 kW NERO sez 2 5 mm 2 ...

Page 35: ... 2 2 kW NERO sez 2 5 mm 2 TRIAC 3 2 kW NERO sez 2 5 mm 2 TRIAC 4 2 kW NERO sez 2 5 mm 2 TRIAC 1 3 kW NERO sez 4 0 mm 2 GATE G2 BIANCO da p to 6 spinotto J5 GATE G3 NERO da p to 7 spinotto J5 GATE G4 ROSSO da p to 2 spinotto J5 GATE G1 GIALLO da p to 5 spinotto J5 TRIAC 2 2 kW NERO sez 2 5 mm 2 TRIAC 3 4 kW NERO sez 4 0 mm 2 TRIAC 4 2 kW NERO sez 2 5 mm 2 TRIAC 1 4 kW NERO sez 4 0 mm 2 ...

Page 36: ... to 6 spinotto J5 GATE G3 NERO da p to 7 spinotto J5 GATE G4 ROSSO da p to 2 spinotto J5 GATE G1 GIALLO da p to 5 spinotto J5 TRIAC 2 3 4 kW NERO sez 4 0 mm 2 TRIAC 3 4 6 kW NERO sez 4 0 mm 2 TRIAC 4 2 kW NERO sez 2 5 mm 2 TRIAC 1 6 kW NERO sez 4 0 mm 2 ...

Page 37: ...c Primary exchanger ON delay idx 005 0 0 240 sec Min temperature of primary exchanger for circulator ON idx 006 30 0 50 C Type of sanitary water storage tank idx 008 0 0 internal with probe 1 external with thermostat 2 external with probe PWM circulator operation speed idx 010 4 1 400 l h 2 800 l h 3 1 000 l h 4 1 200 l h Boiler power selection idx 011 3 1 4 System pressure sensor type idx 012 1 0...

Page 38: ...fault JP7 High temperature heating system radiators Low temperature heating system floor 0 JP8 Combined application Central heating only application 1 JP9 Sanitary water system with storage tank Instantaneous sanitary water system 0 JP10 Boiler application Not usable 0 PRIMARY EXCHANGER MANAGEMENT BOILER BODY Depending on the power level required during the heat demand all or part of the controls ...

Page 39: ...ature measured by the probe dc dispersion coefficient of the building set using the parameter idx 002 HEATING REQUEST When the room thermostat TA contact is closed or following a request by the weekly program if the board is in winter mode the system pump is activated only if the primary exchanger temperature is higher than the temperature set using parameter idx 006 If the temperature value detec...

Page 40: ...boiler control panel A total of ten circulator speeds can be set with ten corresponding separate flow rates Pump programming Manually select the maximum speed profile using the key then use the boiler control panel to select the parameter idx 010 and choose one of the four flow rates available for each speed setting the values from 1 to 4 Set 1 for minimum flow rate or 4 for maximum flow rate set ...

Page 41: ...SW3 Res ERROR Code Meaning F 1 Functional system shutdown due to system pressure below 0 7 bar idx 012 val 1 F 3 Central heating probe fault SM F 8 Safety thermostat TS trip To reset the system press SW3 Res F 9 EEPROM memory hardware failure F 10 System pressure higher than 2 0 bar with functional system shutdown if the pressure exceeds 2 8 bar idx 012 val 1 ...

Page 42: ...41 SPARE PARTS 4 Detail view Electric Box Detail view Body Heating Elements 23 25 29 22 22 ...

Page 43: ...Cod P 7981 6 Left side shell Cod P 8077 7 Power Triacs 40 A 600 V Cod P 2293 8 Return pipe pump body Cod P 7808 9 Elektra Compact N 9 litres expansion tank Cod P 7815 10 Pressure transducer max min pressure Code P 8062 11 Variable head circulator electronic pump Code P 7326 12 Expansion vessel hose Cod P 1572 13 Hydrometer Cod FGB 221 14 Central heating safety valve 0 3 MPa 3 bar Cod P 7602 15 Rig...

Page 44: ...DFWRU Rd P 2153 24 O Ring seal x heating element 3x2 kW Cod FGB 238 25 Elektra Compact 6 12 18 N heating element 3x2 kW Code FGB 224 26 Contact safety thermostat 100 C Cod P 1195 27 Automatic vent valve Cod FGB 228 28 Elektra Compact N Silver Touch front cover Cod P 7829 29 Touch Display Cod P 7980 30 Elektra Compact C N BP L Silver Touch Instrument Panel Cod P 7827 31 Illuminated main switch Cod ...

Page 45: ...013 EU Regolamento riguardante l etichettatura indicante il consumo d energia degli apparecchi per il riscaldamento d ambiente degli apparecchi di riscaldamento misti Regulation regard to the energy labelling of space heaters combination heaters packages of space heater temperature control and solar device and packages of combination heater temperature control and solar device N di identificazione...

Page 46: ...entification No N di identificazione See the serial number Vedi numero di matricola Manufacturer Costruttore FIAMMA GIRO s r l Address Indirizzo via L Landucci n 2 B 51100 PISTOIA ITALY Telephone Telefono 39 0573 532812 Telefax E mail Fax e mail 39 0573 532890 info fiammagiro it Type of equipment Tipo di apparecchio Electric wall boiler Caldaia murale elettrica Trademark Marchio commerciale marked...

Page 47: ......

Page 48: ...mbiboilers uk www electriccombiboilerscompany com FIAMMA GIRO s r l Company group Sede legale e stabilimento via L Landucci n 2 B 51100 PISTOIA ITALY Tel 39 0573 532812 Fax 39 0573 532890 E mail fiammaPT fiammagiro it Filiale e stabilimento via P Bettini n 19 37049 VILLA BARTOLOMEA VR ITALY Tel 39 0442 659028 Fax 39 0442 659045 E mail fiammaVR fiammagiro it www fiammagiro com Code M0111 ...