background image

FIB_FGS-221

Relay Insert 2 * 1.5 KW

Firmware Version : 1.3

Quick Start

To include the Fibaro Switch relay into the network, set the Home Center controller into the inclusion mode 

and then press the button of the device or the push-button B located inside the housing of the switch relay 

three times during 1.5 seconds. The LED will become green for 3 seconds and then turn off. The device is 

now ready to work.

Please refer to the chapters below for detailed information about all aspects of the products usage.

What is Z-Wave?

This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the 

international standard for wireless communication in smart homes and buildings. It is using the 

frequency of 868.42 MHz to realize a very stable and secure communication. Each message is reconfirmed 

(two-way communication) and every mains powered node can act as a repeater for other nodes (meshed 

network) in case the receiver is not in direct wireless range of the transmitter.

Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) transmitting metered or 

measured data or actuators (A) capable to execute an action. Controllers are either static mains powered 

controllers (C) also referred to as gateways or mobile battery operated remote controls (R). This results in a 

number of possible communication patterns within a Z-Wave network that are partly or completely supported 

by a specific device.

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 1 

Summary of Contents for FGS-221

Page 1: ...rt homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act...

Page 2: ...vailable space depends on the size of the traditional switch the dimensions of the wall box and the amount of additional cabling placed in this box This device is designed for a 3 wire system and need...

Page 3: ...connected to the insert contact I The electrical load is then connected to the other pole of the 230 V power supply or with the second pole of the additional power supply The switch can be operated lo...

Page 4: ...ert as shown in the schematics If a bistable switch is connected it has to stay connected until the switch is included into the Z Wave network It is also possible to use a double switch for local cont...

Page 5: ...etwork Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Blinking red green LED indicates that the device is in factory re...

Page 6: ...ion group will receive a common wireless command Association Groups 1 external Switch No 1 max nodes in group 16 2 external Switch No 2 max nodes in group 16 3 max nodes in group 1 Configuration Param...

Page 7: ...200 Commands Sent to Association Group 1 Parameter Number 6 Parameter Size 1 Defines what status changes cause sending out a wireless command Zu allow double click function parameter 15 needs to be tu...

Page 8: ...power down Parameter Number 16 Parameter Size 1 The device will or will not return to the last switch state after a power down Value Description 0 not return to previous state Default 1 return to pre...

Page 9: ...in case of alarm 2 Enable on Alarm will switch on in case of alarm 3 Flashing on Alarm will switch on and off periodically for 10 minutes Default Temperature Alarm Set Relay 1 Parameter Number 33 Par...

Page 10: ...ll switch off in case of alarm 2 Enable on Alarm will switch on in case of alarm Default 3 Flashing on Alarm will switch on and off periodically for 10 minutes Smoke Alarm Set Relay 2 Parameter Number...

Page 11: ...utes Command Classes Supported Command Classes Basic version 1 No Operation version 0 Binary Switch version 1 Version version 1 All Switch version 1 Multi Channel version 2 Multi Channel Association v...

Page 12: ...f bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled de...

Reviews: