1
www.fiduspower.com
Model Number
Output Power
Output 1
Output 2
(1,2)
Efficiency
(4)
Voltage
Current Max
Voltage
Current Max
RHM25012P
250W
12V
20A
5V
2A
90%
RHM25015P
250W
15V
16A
5V
2A
90%
RHM25019P
250W
19V
12.63A
5V
2A
90%
RHM25024P
250W
24V
10A
5V
2A
91%
RHM25030P
250W
30V
8A
5V
2A
91%
RHM25036P
250W
36V
6.66A
5V
2A
92%
RHM25048P
250W
48V
5A
5V
2A
92%
Models & Ratings
Parameter
Minimum
Typical
Maximum
Units
Notes & Conditions
AC Input range
90
264
VAC
Operating temperature
-
40
70
°C
Derate linearly from 100% power at 50°C to 50%
power at 70°C
Efficiency
90
92
%
Dimensions
3 x 5 x
1.46” (76.2
x 127 x 37mm)
EMC
EN55011 Level B conducted and radiated. EN61000
-
3 and EN61000
-
4, harmonics, flicker, Surge, EFT, ESD, conducted and
radiated. IEC 60601
-
1
-
2 4th Ed
Safety
IEC60601
-
1 2006/A1:2013, ES60601
-
1:2005 (R2012), CSA
-
C22.2 No. 60601
-
1:14, EN60601
-
1:2006/A1:2013
Key specifications
RHM250P
Series
Notes
•
Power dense 250W in 3 x
5”
•
Remote on/off and 5V stand by
•
Latest medical approvals IEC 60601
-
1 (3.1) and IEC 60601
-
1
-
2 4th Ed
•
Earth leakage <300uA (BF rated)
•
EN55011 Level B conducted & radiated
•
-
40 to +70°C Operation
•
5 Year warranty
Dimensions:
3 x 5 x
1.46” (76.2
x 127 x 37mm)
250 Watts
The RHM250P series offers 250W in a dense, 3 x
5”
open frame package. The units are designed for
use in medical applications, are very efficient and have low emissions, meeting EN55011 Level B
.
They have a wide temperature range from
-
40 to +70°C and offer low no load power consumption of
<0.3W. Outputs are available from 12 to 48V and all models come with a FiDUS 5 year warranty.
INSTALLATION ADVICE PG5
1. Output 2: Standby Power 5V@2A
2. Output 2: Minimum load 0.3A
3. Looms kits available, see
‘
Installation Advice
’
pg5
4. Efficiency at full load and nominal line voltage