Features

• Wireless communication between the platform

and remote control.

• The remote stores in the body of the platform for

convenient carrying.

• Solid aluminum platform with rubber corners

means your scale is rugged enough for the field.

• Diamond plate style rubber pad keeps cylinders

from sliding around the platform.

• Easy synchronization between the platform and

the remote.

• Highly accurate weight sensor.
• Magnetic hat on the remote allows for convenient

display location and keeps your hands free.

• Zero (tare) the scale from the remote.
• Remote control remembers the last zero point,

even after powering on and off (you won’t lose
your calibration even if the scale turns off).

• Bright backlight allows you to read the remote

display in any lighting.

• Auto-power off conserves battery life.
• Battery life for both the platform and remote con-

trol are visible at all times.

• Wireless signal strength indicator.
• The platform automatically goes into standby

when the remote is turned off.

• Long battery life.

Safety

This instrument complies with the requirements of

the following: 

FCC Rule Part: 15C
ID: VEARF915

CE:  EN300 220

C-Tick

WIReleSS
ReFRIgeRanT
SCale: SRS2C

opeRaToR’S Manual

Introduction

The  SRS2C  is  a  rugged  wireless  scale  designed

specifically  for  weighing  refrigerant  cylinders.  The
wireless remote control is securely stored inside the
back of the rugged scale platform. The remote has a
bright blue backlight. The remote can be hung by the
magnetic  hat  for  easy,  hands-free  measuring.  The
platform is made of solid aluminum with rubber cor-
ners to protect against the hazards of daily use.

SRS2C Quickstart

OPERATION:

1. Turn on the remote. The platform will turn on

automatically if synchronized and in stand-by
mode.

2. Zero (tare) the scale by holding the ZERO button

on the remote for one second.

3. Press the UNITS button on the remote to select

pounds or kilograms.

4. Read weight directly on the remote’s display.

SYNCHRONIZATION:

If  “no  Sig”  or  “CH  USEd”  is  displayed  when  the

remote is powered on, you need to SYNC the remote
to your platform.
1. Check that the platform is powered on.
2. Hold the SYNC button on the remote until search

pattern appears.

3. During the search, hold the SYNC button on the

platform until green SYNC LED blinks.

4. If the sync is successful, the SYNC LED will go

solid and a reading will be shown on the display.

PRESS FOR 1 SECOND

AUTO-OFF

SRS2

Wireless 

Refrigerant 

Scale

ZERO

SYNC

UNITS

ON/OFF

PRESS FOR

 1 SECOND

Wireless Remote

Platform

Opman SRS2C v16

APO:

Auto Power Off turns the wireless display off

after 30 minutes. To disable APO, hold the back-
light button and then press the ON/OFF button.

Battery life remaining for remote control.

Battery life remaining for the scale platform.

Wireless signal strength between remote and platform.

Major unit reading, in pounds  (Lb) or kilograms (Kg).

Minor unit reading, in ounces (oz) or grams (g). 

Combine with major unit for total weight. 
For example: if the upper display shows 14 Lb and
the lower display shows 11.50 oz, the total weight is
14 Lbs and 11.50 oz.

Tech Tips for the Field

Respect the Environment

Always  use  low-loss  hose  fittings  to  minimize

harmful refrigerant gases entering the atmosphere.

Hoses Affect Weight

There are two ways to handle this issue:

EASY WAY
Connect the hoses to the system before zeroing
the scale. Once the system is stable, log the
weight displayed before disconnecting from the
system.

HARD WAY
Zero the scale without hoses connected. Then,
connect hoses to the system, and add or recover
refrigerant. Disconnect the hoses from the system
and the tank. Now the display will show the
weight of the added or recovered refrigerant.

G-value compensation

The  Earth’s  gravitational  strength  varies  depend-

ing on your location on the Earth’s surface. This can
affect the accuracy of your scale readings. 

In order to get the most accurate readings possible

you may want to adjust the g-value of your SRS2C. 

In order to adjust the g-value of your SRS2C follow

the steps below:
1. Hold the UNITS button while powering on the

SRS2C display. This will take you into the g-value
set up. “G-St” will display momentarliy followed by
your SRS2C’s current g-value.

2. Press the UNITS button to scroll through 9

default g-values and a 10th custom input. To
input a custom value press the UNITS button until
“G-St” is shown on the display. Then use the
BACKLIGHT and SYNC buttons to increase or
decrease the g-value.

3. When you have selected the appropriate g-value

for your area, press the ZERO button to exit.

* Default G-value setting.

G-Values

1.) Los Angeles

9.796*

2.) Taipei

9.790

3.) Mexico City

9.779

4.) Kolkata

9.788

5.) Rio De Janeiro

9.788

6.) Sydney

9.797

7.) Tokyo

9.798

8.) Brussels

9.811

9.) Chicago

9.803

10.) Custom input

9.---

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Reviews: