background image

Color Screen Multi-channel Weather Station User Manual

1

1. Introduction

Thank you for purchasing the color screen weather station with temperature,
humidity, barometric, moon phase and advanced forecasting. This device
can receive signals up to 3 sensors. All the sensors measure temperature
and humidity then transmit to the console and displayed on Outdoor
segment.

The following use guide provides step by step instructions for installation,
operation and troubleshooting.

2. Product Features:

Figure 1

Summary of Contents for WH2810

Page 1: ...humidity barometric moon phase and advanced forecasting This device can receive signals up to 3 sensors All the sensors measure temperature and humidity then transmit to the console and displayed on Outdoor segment The following use guide provides step by step instructions for installation operation and troubleshooting 2 Product Features Figure 1 ...

Page 2: ...10 Time alarm with snooze 11 Moon phase 12 LED backlight 13 Wall hanging or free standing 14 Included transmitter Outdoor sensor 15 Synchronized instant reception 3 Getting started Note The power up sequence must be performed in the order shown in this section remote transmitter s first display console second to avoid the console synchronization time out This weather station consists of a console ...

Page 3: ...Color Screen Multi channel Weather Station User Manual 3 Console Figure 2 Remote sensor Figure 3 LIGHT SNOOZE Key Hanging hole Power jack Folding bracket ...

Page 4: ...ween 20 Cand 60 C and fresh lithium batteries for outdoor temperature range between 40 C and 60 C 1 Move the transmitter s about 2 to 3m away from the display console if the transmitters are too close they may not be received by the display console With multiple transmitters make sure all transmitters are powered up and displaying different channels on the display 2 Remove the battery door on the ...

Page 5: ...rect channel number CH and temperature units of measure are on the display as shown in Figure 5 Figure 5 1 Temperature 2 Temperature units F or C 3 Channel number 4 Relative humidity 9 Close the battery door 10 Repeat for the additional remote sensor verifying each remote is on a different channel 3 3 Sensor Operation Verification Verify the humidity sensors match closely with all of the sensors i...

Page 6: ...r sends the RCC signal to display console Once the radio controlled time is received RCC reception icon will turn on in the display console reference Figure 8 If the signal reception is not successful within 3 minute the signal search will be cancelled and will automatically resume every six hours until the signal is successfully captured The regular RF link will resume once RCC reception routine ...

Page 7: ...nce and then light up The brightness selection is set to high when plugged into the adapter Press the LIGHT SNOOZE key can adjust among HIGH MIDDLE OFF level according to your preference 2 Remove the battery door on the back of the display Insert three AAA alkaline or lithium avoid rechargeable batteries in the back of the display console Looking at the back of the unit left to right the polarity ...

Page 8: ...r 5 seconds when on back up battery power only Only when you use power adapter it will the back light be continuously on 4 The console will instantly display indoor temperature humidity barometer moon phase date and time The remote search icon will turn on 3 6 1 Display Console Layout Note The following illustration shows the full segments of the LCD for description purposes only and will not appe...

Page 9: ...e 8 Barometric pressure 20 Indoor humidity 9 Outdoor sensor signal 21 Min indoor humidity 10 Channel number 22 Max indoor humidity 11 Outdoor temperature 23 MAX MIN DAILY icon 4 Console Operation Note The console has four keys for easy operation TEMP key ALM key BARO key and SET CH key There are four program modes Set Mode Alarm Mode calibration mode and Min Max Mode Any program mode can be exited...

Page 10: ...decrease SET CH Minute of Day Press TEMP to increase BARO to decrease SET CH D M M D Format Press TEMP or BARO to toggle between D M and M D format SET CH Year Press TEMP to increase BARO to decrease SET CH Month of Year Press TEMP to increase BARO to decrease SET CH Day of Month Press TEMP to increase BARO to decrease SET CH Temperature Units of Measure Press TEMP to toggle between degF and degC ...

Page 11: ...and RST OFF 3 Time Zone Settings Press the SET CH key again to adjust the Time Zone TZ setting Press the TEMP key or BARO key to adjust the time zone from 12 to 12 based on the number of hours from Coordinated Universal Time or Greenwich Mean Time GMT 4 12 24 Hour Format Press the SET CH key again to adjust the 12 24 hour format setting Press the TEMP key to change between 12 hour and 24 hour form...

Page 12: ...units between hPa mmHg or inHg 13 Northern Hemisphere NTH or southern Hemisphere STH select Press the SET CH key again to toggle the pressure units between NTH or STH Note In the Set mode press the TEMP key or BARO key to change or scroll the value Hold the TEMP key or BARO key for 3 seconds to increase decrease rapidly Note Press the LIGHT SNOOZE key or wait 30 seconds for the programming mode to...

Page 13: ... relative pressure for your location locate an official reporting station near you the internet is the best source for real time barometer conditions such as Weather com or Wunderground com and set your weather station to match the official reporting station 4 3 3 Relative vs Absolute Pressure While in normal mode Press and hold the BARO button for 2 seconds you can switch between absolute ABS pre...

Page 14: ...l reporting station 4 4 Dew point While in normal mode Press the TEMP key to view the Dew Point of current channel in the outdoor temperature Segment If key idle 30 seconds the display will return to normal mode To exit the Dew Point display mode press the SNOOZE LIGHT key on the top of the display console or wait 30 seconds for the timeout to take effect 4 5 ALARM Mode While in normal mode press ...

Page 15: ...this temperature range the low temperature alarm would be triggered The LO temperature icon will appear and flash on the console If the BEEP is switched on a sound ALARM would be also activated when Low temperature ALARM occurs 4 5 3 Cancelling the ALARM When time ALARM or Low temperature ALARM is triggered press any key to close the sound alarm During time ALARM press LIGHT SNOOZE key can enter s...

Page 16: ...o next parameter Press the ALARM button to cancel offset values Example 1 The calibrated temperature from a red spirit thermometer or actual temperature is 30 0 C The uncalibrated or measured temperature is 28 7 C Offset Calibrated Temperature Uncalibrated Temperature 30 0 28 7 1 3 C Enter the temperature offset 1 3 C Example 2 The calibrated absolute pressure from a calibrated pressure sensor or ...

Page 17: ...ibrated range 10hpa 4 7 MAX MIN Mode The Max Min weather data are displayed on the bottom of each parameter segment Left one in red color is MAX record right one in blue or yellow is MIN record All the MAX MIN records are based on since last reset time after turned on Max temperature Min temperature Max humidity Min humidity All MAX MIN records of all sensors can be cleared if you press and hold t...

Page 18: ...ast for your location Six color forecast icons use changing atmospheric pressure to predict weather conditions for the next 12 hours Note The weather forecast or pressure tendency is based on the rate of change of barometric pressure In general when the pressure increases the weather improves sunny to partly cloudy and when the pressure decreases the weather degrades cloudy to rain Sunny Partly Cl...

Page 19: ...st Quarter Waxing Gibbous Full Waning Gibbous Third Quarter Waning New 4 8 3 Temperature Humidity Trend Arrows The temperature 2 F 1 C and humidity 3 trend indicators update every 30 minutes The trend reflects changes over the past 3 hours E G At 3 00 compares to 12 00 data at 3 30 compares to 12 30 Temperature or Humidity increased in past 3 hours Temperature or Humidity did not change in past 3 ...

Page 20: ...sor or transmitter and the display console or the receiver to resynchronize while in normal mode Press and hold SET CH and TEMP button for 5 seconds to register the outdoor transmitter Please wait several minutes for the remote sensor reports in Do not touch any buttons until synchronization is complete If the synchronization fails reset the console by removing one battery from the display console...

Page 21: ...h the actual value of the quantity being measured HectoPascals hPa Pressure units in SI international system units of measurement Same as millibars 1 hPa 1 mbar Hygrometer A hygrometer is a device that measures relative humidity Relative humidity is a term used to describe the amount or percentage of water vapor that exists in air Inches of Mercury inHg Pressure in Imperial units of measure 1 inch...

Page 22: ...9 5 only guaranteed between 20 to 90 1 Outdoor Humidity 1 0 to 99 5 only guaranteed between 20 to 90 1 Barometric Pressure 300hpa to 1100hpa 3 hpa only guaranteed between 700 to 1100hpa 0 1hpa 6 3 Power Consumption Base station 6V DC adaptor included 3 x AAA 1 5V Alkaline batteries not included Remote sensors 2 x AA 1 5V Alkaline batteries not included Battery life Minimum 12 months for base stati...

Reviews: