background image

Firegear, LLC., -IM-138 2/2012

Models:

BCOL-18,24,30NG

BCOL3-18,24,30NG 

For use with Natural gas only.

Installation

 Instructions

Check with your local building code agency before you begin installation to ensure compliance with local codes, including 

the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need 

clarification of any of the instructions contained here, contact the Technical Services Dept., Firegear LLC.,. 888-220-4333.

DO NOT DISCARD THIS MANUAL

CAUTION

•  Important  operating 

a n d   m a i n t e n a n c e 

instructions included.

• 

Leave this manual with 

party  responsible  for 

use and operation.

• 

Read,  understand 

and  follow  these 

instructions  for  safe 

i n s t a l l a t i o n   a n d 

operation.

DO

NO

T

DIS

CA

RD

If the information in these instruc-

tions is not followed exactly, a 

fire may result causing property 

damage, personal injury, or death.

 

•  Do not store or use gasoline or other flam-

mable vapors and liquids in the vicinity of 

this or any other appliance.

•  What to do if you smell gas:

-  Do not try to light any appliance.

-  Do not touch any electrical switch. Do not 

use any phone in your building.

-  Immediately call your gas supplier from 

a  neighbor’s  phone.  Follow  the  gas 

supplier’s instructions.

-  If you cannot reach your gas supplier, call 

the fire department.

•  Installation and service must be performed 

by a qualified installer, service agency, or 

the gas supplier.

WARNING

HOT! DO NOT TOUCH

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

WARNING

•  Keep children away.  

•  CAREFULLY SUPERVISE children in same room as 

appliance.

•  Alert  children  and  adults  to  hazards  of  high 

temperatures.

•  Keep  clothing,  furniture,  draperies  and  other 

combustibles away. 

Glass  and  other  surfaces  are  hot  during 

operation and cool down.

Installation  and  service  of  this 

appliance should be performed by 

qualified personnel. Firegear LLC.,. 

suggests  NFI  certified  or  factory-

trained professionals, or technicians 

supervised  by  an  NFI  certified 

professional.

In the Commonwealth of Massachusetts:

•  This appliance must be installed by a licensed plumber 

or gas fitter.

•  The chimney flue damper, when used with gas logs, will 

be welded open or completely removed.

•  A CO detector shall be installed in the room where the 

appliance is installed.

Summary of Contents for BCOL-18NG

Page 1: ...mell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING HOT DO NOT T...

Page 2: ...me to the Firegear LLC family of appliance products Congratulations Homeowner Reference Information Model Name Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer phone Notes We recommend that you record the following pertinent information about your gas log set A Design and Installation Considerations The Gas Log Hearth Kit consists of the following Log S...

Page 3: ...ed and cleaned by qualified professionals Firegear LLC recommends that NFI or CSIA certified professionals or technicians under the direction of certified professionals conduct a minimum of an NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and the chimney is properly secured Do...

Page 4: ...ly be installed in a solid fuel burning fireplace with the flue damper clamped open according to Tables 1 and 2 The fireplace must be constructed of non combustible material The minimum permanent free opening in square inches that must be provided by the fireplace chimney or damper to vent the flue gases is provided in Tables 1 and 2 If the free opening is smaller than the specified area do not us...

Page 5: ...nimum Fireplace Dimensions Log Set Front Opening Depth Height Rear Width Natural BTU BCOL18 27 in 16 in 18 in 19 in 40 000 BCOL24 34 in 20 in 18 in 22 in 73 000 BCOL30 40 in 20 in 18 in 29 in 80 000 BCOL318 32 in 23 in 22 in 21 in 76 000 BCOL324 34 in 23 in 22 in 22 in 86 000 BCOL330 40 in 23 in 22 in 29 in 86 000 H Inspect the Appliance and Components Remove the contents from burner box Attached ...

Page 6: ...here the flame is blue This will achieve the desired realism The gas burns at the point of the least resistance In case of an uneven flame pattern it may be necessary to adjust the materials in the pans using an object such as a screwdriver to achieve the desired effect Place desired amount of lava granules on the floor of the fireplace DO NOT ALLOW THE GRANULES TO COME IN CONTACT WITH THE FLAMES ...

Page 7: ... If necessary seek expert advice Do not operate this appliance Cleaning Periodic examination and cleaning of the venting system of the fireplace should be done before initial use and at least annually by a qualified agency M Cleaning and Maintenance Instructions Always remember Do not place any combustible material near the appliance Do not place any paper trash or other material on the log set or...

Page 8: ...these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas s...

Page 9: ...ose my fireplace damper to get more heat from my vented gas log set No Vented gas logs are designed to be operated with the damper in the fully opened position This gas log set produces carbon monoxide gas The damper must be removed or clamped fully open using the C clamp provided with the set My gas logs make a whistling noise when I burn them What causes this This behavior is normally caused by ...

Page 10: ...24 30 BCOL 3 18 24 30 Description of Part 18in 24 in 30 in Qty 1 Burner Pan Grate Assembly BPA 300 18 BPA 300 24 BPA 300 30 1 2 Burner Pan Grate Assembly 3 Tier Only BPA 300 33 BPA 300 35 BPA 300 40 1 3 Gas Line Connector FT 18 FT 24 FT 30 1 4 Damper Clamp 10 1065 10 1065 10 1065 1 3 4 2 1 ...

Reviews: