background image

OPERATING INSTRUCTIONS MANUAL

FLE-60RC

(575V)

INDUSTRIAL / COMMERCIAL ELECTRIC HEATER

(OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

Suitable for indoor installation  Only / Unvented / Unattended Type

26 Benfield Drive, St.Catharines, Ontario Canada L2S 3V5  

(P) 905-685-4243 - (F) 905-685-0113

Summary of Contents for FLE-60RC

Page 1: ...0RC 575V INDUSTRIAL COMMERCIAL ELECTRIC HEATER OPERATOR MUST RETAIN FOR FUTURE REFERENCE Suitable for indoor installation Only Unvented Unattended Type 26 Benfield Drive St Catharines Ontario Canada L2S 3V5 P 905 685 4243 F 905 685 0113 ...

Page 2: ...MATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT TH...

Page 3: ...e FLE 60RC includes a permanent 20 inlet duct adapter A maximum of 25ft of ducting can be used on the outlet and inlet of the heater ONLY 20 INCH DIA DUCTING CAN BE USED ON THIS HEATER Safety Always verify that you have proper voltage supply 575V It is important to check the wiring connections inside the heater before plugging in the Cam Locks Use a meter to measure volt supply to each cam lock Wo...

Page 4: ... assembly and ensure the motor and blade are operating properly 4 Compressed air may be used to keep components free of dust and dirt build up Pre Start Checklist 1 Heater must be level and lockable wheels must be in the lock position 2 Make sure blower switch and both heat switches are in the OFF positions 3 Make sure the air intake is free from any obstruction s 4 Make sure the heater oulet is f...

Page 5: ...PHASE UNIT CONNECTION 4 Turn on power supply 5 Pull Master button to the out position 6 Determine Manual or Remote Thermostat if remote set desired temperature 7 Turn Blower on off switch to the ON position The blower will start and the green air flow light will come on 8 Turn on heater settings as desired 60kW 20kW 40kW combined Failure to have proper air flow will cause unit to overheat and shut...

Page 6: ...43DEG C 67 DB 40 kW 164 000 2800 85DEG F 30DEG C 63 DB 20kW 82 000 2450 50DEG F 10DEG C 63DB FAN ONLY 3900 71DB SHUTDOWN 1 Move all heater setting controls to the OFF position 2 Leave Fan in the ON position for 3 5 minutes 3 Turn Fan OFF blower is preset to run for 30 seconds before coming to a complete stop 4 Push Master button IN 5 Shut off all power source 6 Disconnect all power sources 7 Store...

Page 7: ...000 btu BLOWER 1 1 2 H P TEMPERATURE RISE above ambient 20KW 50 DEG F 40KW 85 DEG F 60 KW 110 DEG F AMP DRAW MOTOR 3900CFM 2 AMPS 20KW 2450 CFM 24 AMPS 40KW 2800 CFM 40 AMPS 60KW 3300 CFM 64 AMPS TOTAL AMP 69AMPS DB noise level FAN ONLY 71DB 20KW 63DB 40KW 63DB 60KW 67 DB INLET OUTLET SIZE 20 ADAPTERS DIMENSIONS 32 X 48 X 25 1 2 H X L X W IN WEIGHT 290 LBS unboxed ...

Page 8: ...EMBLY VENTURI VARIABLE SPEED DRIVE 1 5 HP MOTOR FLE 603A FLE 604A FUSES FLE 628 60 amp class T FLE 629 30amp class T FLE 630 5 amp class CC FLE 631 1 2amp class CC FLE 632A 1 amp AGC glass TRANSFORMER FLE 627A 575V GROUNDING BLOCK FLE 621 RELAY FLE 626 2 PER UNIT HIGH LIMIT FLE 623 200F ...

Page 9: ...WITCH FLE 633 20KW 40KW THERMOSTAT MANUAL BLOWER ON OFF SAIL SWITCH CONTACTORS FLE 625 32A 3P FLE 624 65A 3P EMERGENCY STOP BUTTON FLE 634 GREEN AIR PROVEN LIGHT FLE 636 HIGH LIMIT AIR PROVEN LIGHT THERMOSTAT FLE 635 FV 414B FLE 641 ...

Page 10: ...ABLE FLE 615 BLUE FLE 616 BLACK FLE 617 GREEN FLE 618 RED FLE 611 BLUE FLE 612 BLACK FLE 613 GREEN FLE 614 RED CAM LOCK PANEL N C CONTACT BLOCK N O CONTACT BLOCK FLE 639A 3 PER UNIT FLE 640A 7 PER UNIT SNAP COVERS PANEL FLE 611A BLUE FLE 612A BLACK FLE 613A GREEN FLE 614A RED ...

Page 11: ...P N DESCRIPTION FEH 60FR OUTER FRAME FEH 616 TOP PANEL FEH 611C LEFT SIDE PANEL FEH 610C RIGHT SIDE PANEL FEH 612C FRONT PANEL FEH 614 REAR SIDE PANEL FLE 170 CONTROL PANEL RAIN GUARD BODY PANELS ...

Page 12: ...TOR PULLEY PRIOR TO 2018 FLE 609 6 LOCKABLE SWIVEL CASTER TWO REQUIRED FLE 610 6 RIGID CASTER TWO REQUIRED FLE 611 BLUE MALE PANEL CAM LOCK FLE 611A BLUE SNAP COVER FLE 612 BLACK MALE PANEL CAM LOCK FLE 612A BLACK SNAP COVER FLE 613 GREEN MALE PANEL CAM LOCK FLE 613A GREEN SNAP COVER FLE 614 RED MALE PANEL CAM LOCK FLE 614A RED SNAP COVER FLE 615 BLUE FEMALE DETACHABLE CAM LOCK FLE 616 BLACK FEMAL...

Page 13: ...R PROVEN LIGHT LENS ONLY FLE 636A GREEN AIR PROVEN LIGHT MODULE ONLY LED FLE 636B GREEN AIR PROVEN LIGHT LED COMPLETE FLE 637 BULBS FOR FLE 635 FLE 636 FLE 639A N C CONTACT BLOCK DUST RESISTANT THREE PER HEATER FLE 640A N O CONTACT BLOCK DUST RESISTANT SEVEN PER HEATER FLE 641 SAIL SWITCH COMPLETE FLE 643 FUSE HOLDER 5AMP FLE60 10AMP FLE150 FV 414B THERMOSTAT CONNECTION FLE DA60F20 OUTLET DUCT ADA...

Page 14: ...34 TB 3 TB 3 RD 16 AWG 2 16 PS1 AIR FLOW 11 12 R1 0131 11 12 R2 0139 1 25 A FU1 TB 2 X1 34 RD 16 AWG 1 TB 5 A1 A2 R1 0135 0141 TB X2 TB X2 G PL1 AIRFLOW PROVEN TB 5 R PL2 AIRFLOW NOT PROVEN R PL3 OVERTEMP RD 16 AWG 3 40 RD 16 AWG 4 40 2 BK 14 AWG 22 SEW 2 3 BK 14 AWG 22 SEW 2 TB 6 TB 7 TB 3 TS1 OVERTEMP TB 8 A1 A2 R2 0137 0141 TB X2 21 24 R1 0131 21 24 R2 0139 TB 10 OFF ON SS2 BLOWER MANUAL REMOTE...