background image

 

Page 1 of 4 

   

 

 

 

 

                           

 

Gotham 900 

Featuring

 

 

This product is only suitable for well insulated spaces or occasional use

 

 

 

 

 

     

  Installation & Precautions  

 

Carefully remove the fire from the packing, checking that neither the heater nor the power cable has been damaged during transport. Do not 

operate the fire if either is damaged.  Please bear in mind the weight of the fire before removal from the packaging and installation. Consider if 

help is required. Any alteration to the power cable should only be done by a qualified electrician and to the Flamerite Fires guidelines stated 

below.  Your fire is guaranteed for one year from the date of purchase. In the unlikely event of a breakdown you have access to our customer 

services team, simply call 01543 251122 during office hours, 9am – 5pm or e-mail o

info@flameritefires.com

  The accessories are found in a box 

that is packed at the side of the fire.  

 

INSTALLATION 

Where a chimney is not blocked off completely it will cause the heater to cut out during use.  ONLY if installing into a chimney and you are not 

sure that you have cut off the draw 100% we recommend covering the slots in the rear and at either side. 

 

Automatic safety cut out: The heater is fitted with an automatic cut out to prevent any damage due to overheating. The element will continually 

and automatically cut out if the airflow is obstructed. Never cover the air outlets.  To reset, switch the fire off, disconnect from the mains supply, 

remove the cause of the overheating, check the micro switches and allow to cool for a suitable period then switch the fire back on. Caution: In 

order to avoid a hazard due to inadvertent resetting of the thermal cut out, the appliance must not be supplied through an external switching 

device, such as a timer, or connected to circuit regularly switched on and off by a utility.    

 

Electrical connections. Your appliance comes fitted with a plug that incorporates a 13A fuse. The replacement fuses must be 13A and ASTA 

approved. If the fuse cover is lost the plug must not be used until a replacement cover, of the same colour, is obtained from an electrical retailer. 

The appliance is fitted with a moulded plug if it is necessary cut off the plug, for any reason, it must be discarded immediately with the fuse 

removed. Under no circumstances should any attempt be made to reuse the plug, do not insert into any 13A socket as this could cause a hazard. If 

the mains cable is damaged it must be replaced by the manufacturer or an authorised technical service centre. 

 

WARNING THIS APPLIANCE MUST BE EARTHED 

IMPORTANT 

The wires in the mains lead are coloured in accordance with the following code. 

 

Green and yellow: 

EARTH 

Blue: 

NEUTRAL 

Red: 

LIVE 

As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings in your plug proceed as follows: - 

 

The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E, or 

coloured green or coloured green and yellow, or marked with the earth symbol   

 

The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N, or coloured 

black. 

 

The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L, or coloured 

red.  

Insert the plug tightly into its IEC connector underneath the fire if not already done so. If the removal of the plug is absolutely necessary for 

installation, cut off in an area within 100mm only of the plug itself.   Any further will affect your warranty. 

 

Fixing set (not including white decorative screw head covers). 

 

 

Summary of Contents for Gotham 900

Page 1: ...ugh an external switching device such as a timer or connected to circuit regularly switched on and off by a utility Electrical connections Your appliance comes fitted with a plug that incorporates a 13A fuse The replacement fuses must be 13A and ASTA approved If the fuse cover is lost the plug must not be used until a replacement cover of the same colour is obtained from an electrical retailer The...

Page 2: ...need to be fixed at two points Warning Due to the fireplace being of a narrow design you should be mindful that during the installation there is a high risk of falling forwards or backwards We recommend two persons throughout Firstly the upper wall brackets should be fixed to the wall with the highest point of the chamfered edge facing forward upward Fig 1 A corresponding chamfered edge on the sui...

Page 3: ...glass to sit into the channel in front of the fuel bed To remove the glass in the open fully tilted position hold from the very top pull out of the channel and carefully remove through the opening bottom edge first Fig 4 Fitting Frame or Dresser Rail The dresser rail is a long black magnetic U channel that provides a neat edge along the bottom of the fire Simply fit the rear of the channel in fron...

Page 4: ...se by persons or children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning the use of the appliance by the person responsible for their safety Children should be supervised to ensure they do not play with this appliance PROBLEM SOLVING No power to the fire Check the wall socket plug fuse and la...

Reviews: