background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

INSTALLATION AND USER INSTRUCTION

GUIDE

Aviator Stove

Model No (s)

MBSC11ME 

Electric Stove

This guide should be used to install and care for
your Flavel Electric heater.
Read all information carefully prior to installation
and use.

Summary of Contents for MBSC11ME

Page 1: ...161 620 6677 INSTALLATION AND USER INSTRUCTION GUIDE Aviator Stove Model No s MBSC11ME Electric Stove This guide should be used to install and care for your Flavel Electric heater Read all information carefully prior to installation and use ...

Page 2: ...EVER install the heater close to combustible material i e curtains or similar Allow a minimum of one metre around the heater NEVER route the mains cable beneath carpet NEVER use aerosols or similar close to the heater NEVER use the heater to dry clothes or similar NEVER use the heater by means of an automatic control or timer as this may cause risk of fire if the heater is moved or covered The app...

Page 3: ...m2 The appliance and surround should therefore be located close to a suitable mains socket to enable connection The electrical socket MUST be easily accessible to allow disconnection This appliance must not be directly installed on a carpet or similar material We recommend that it is fitted onto a hearth or similar non combustible material This heater MUST be earthed If in any doubt consult a suit...

Page 4: ...he side and rear panel If fitted into an open draught type fireplace or chimney then it may be advisable to blank off the aperture to reduce the amount of draught created through the fireplace which can cause operation of the safety cut out Unpacking The Appliance This Flavel Electric heater is supplied in a single pack carton All Instructions should be read prior to unpacking or installing the ap...

Page 5: ...ings it may be necessary to wait for the fire to reset before turning heat settings back on This is due to the normal operation of the safety cut out device IMPORTANT Safety Cut Out This appliance is fitted with an automatic safety cut out This operates if the air outlet beneath the canopy becomes covered or blocked This will prevent the fan heater from operating In order to RESET the appliance th...

Page 6: ... fails to oper ate CHECK the fuse within the wall socket plug If after car rying out both of the above procedures the appliance still fails to operate then call a suitably qualified person or CFM Europe Service Engineer Care and Cleaning Always dis connect the appliance from mains supply and allow to cool before any cleaning operation Trim parts may be cleaned using a clean damp cloth Never use an...

Page 7: ...mportant that any electrical work is undertaken by a suitably qualified competent person CHANGING THE LIGHTBULB Disconnect from mains supply Remove brass trim three parts Remove coalform retaining brackets LH RH secured with two screws Remove one of two screws retaining flame effect disc and rotate away from bulb Remove bulb from bulbholder and refit new 60W firelglow bulb Refit the flame effect d...

Page 8: ...tacting CFM Europe Ltd For Advice Customer Address including postcode Model No Serial No Brief Description of Fault Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations contained within this book cannot be guaranteed Part No B 59630 Issue 1 CFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Telephone General Enquiries 01782...

Page 9: ...Supplied By www heating spares co Tel 0161 620 6677 ...

Page 10: ...Supplied By www heating spares co Tel 0161 620 6677 ...

Reviews: