background image

BROADBAND   LINEAR   AMPLIFIER

WITH   A±B   INPUTS   AND   DC-­‐OFFSET

Model   A400X

   

HIGH   VOLTAGE   

FIXED   GAIN   

BROADBAND

   

±200V   

20x   

DC   to   ca   500   kHz

   

150mA   

   

FULL   SCALE

   

LOW   OUTPUT   IMPEDANCE   

HIGH   SLEW   RATE

   

<0.1   Ω   

400   V/µs

ELECTRONICS AB

WWW.FLCE.SE

FLC Electronics AB

Sippedalsvägen 8

S - 433 31 Partille, Sweden

Tel. +46 31 741 2631

Fax +46 31 44 61 10
Fax +46 31 41 75 30

VAT No. SE556506606401

Emai

flce@flce.se

Web 

http://flce.se

Summary of Contents for A400X

Page 1: ...BAND 200V 20x DC to ca 500 kHz 150mA FULL SCALE LOW OUTPUT IMPEDANCE HIGH SLEW RATE 0 1 400 V s ELECTRONICS AB WWW FLCE SE FLC Electronics AB Sippedalsv gen 8 S 433 31 Partille Sweden Tel 46 31 741 26...

Page 2: ...used separately allow the unit to act as inverting or non inverting amplifier Any function or arbitrary waveform generator or any other signal source with a voltage up to 10 V can be used as an input...

Page 3: ...e se for advice before opening the instrument case Keep input signals within 10 V range Never connect the high voltage output to the input of the instrument TROUBLESHOOTING Problem Condi on Solu on No...

Page 4: ...preferably by email info flce se Inside the cabinet exist hazardous voltage levels and the amplifier circuit is sensitive to static discharge FLC Electronics AB recommends to monitor the output signal...

Page 5: ...cy response without load and with 300pF and 400 pF load respectively is shown in the following diagram 1 10 100 1000 1 10 100 1000 10000 Amplitude peak to peak V Frequency kHz without load load 300pF...

Page 6: ...max 150 mA Operating Ambient Temperature 0 C to 30 C Storage Temperature 0 C to 60 C Relative Humidity up to 90 operation 30 to 50 storage Power Requirements 100 110 V or 220 230 V 50 60 Hz Fuse 100 1...

Page 7: ...furnish service under this warranty to repair damage resulting from attempts by personnel other than FLC Electronics representatives to install repair or service the product to repair damage resulting...

Page 8: ...li er during power up and power down Never connect the output to the input of the ampli er The ampli er may be overheated if the output is short circuited for a long me The maximum allowable capaci ve...

Page 9: ...d to the following standards as listed in the official Journal of the European Communities EN 50081 1 Generic Emissions EN 55022 Conducted emission interference voltage class B EN 55022 Radiated emiss...

Reviews: