background image

User’s Guide

Pocket Multimeter
4000 Count Autoranging DMM
Model: DM110

Copyright © 2006 Extech Instruments Corporation. All rights reserved
including the right of reproduction in whole or in part in any form.

DM110-EU-EN V2.2 06/09

Safety

International Safety Symbols

This symbol, adjacent to another symbol or
terminal, indicates the user must refer to the manual
for further information.

This symbol, adjacent to a terminal, indicates that,
under normal use, hazardous voltages may be
present.

Double insulation

Safety Precautions

1.

Improper use of this meter can cause damage, shock, injury or
death. Read and understand this users manual before
operating the meter.

2.

Make sure any covers or battery doors are properly closed and
secured.

3.

Always disconnect the test leads from any voltage source
before replacing the battery or fuses.

4.

Do not exceed the maximum rated input limits.

5.

Use great care when making measurements if the voltages are
greater than 25VAC rms or 35VDC. These voltages are
considered a shock hazard.

6.

Always discharge capacitors and remove power from the
device under test before performing Capacitance, Diode,
Resistance or Continuity tests.

7.

Remove the battery from the meter if the meter is to be stored
for long periods.

Description

Meter Description

1.

3 3/4 Digit (4000 count)

2.

RELATIVE button

3.

SELECT button

4.

DATA HOLD button

5.

Hz/DUTY button

6.

Function switch

7.

Rubber holster

8.

Test leads

Specifications

Electrical Specifications

Function

Range

Accuracy

DC Voltage

400.0mV

(0.7% rdg + 3d)

4.000V, 40.00V,

(1.0% rdg + 3d)

400.0V,500V

(1.3% rdg + 3d)

AC Voltage

(40-400Hz)

4.000V, 40.00V

(1.0% rdg + 10d)

400.0V, 500V

(2.3% rdg + 5d)

DC Current

40.00mA

(2.0% rdg + 5d)

400.0mA

AC Current

(50-60 Hz)

40.00mA

(2.5% rdg + 10d)

400.0mA

Resistance

400.0

, 4.000k

,

40.00k

, 400.0k

(2.0% rdg + 5d)

4.000M

(5.0% rdg + 5d)

40.00M

(10.0% rdg + 5d)

Capacitance

4.000nF

(5.0% rdg + 0.3nF)

40.00nF

(5.0% rdg + 30d)

400.0nF

(3.0% rdg + 15d)

4.000µF, 40.00µF,

200.0µF

(10.0% rdg + 15d)

Frequency

9.999Hz, 99.99Hz,

999.9Hz, 9.999kHz,

99.99kHz, 999.9kHz,

10MHz

(2.0% rdg + 5d)

Duty Cycle

0.1-99%

(2.0% rdg + 5d)

Max input voltage

500V AC/DC

Input Sensitivity,

10Vrms min. <9.999KHz

(Frequency Ranges)

40Vrms min. >99.99KHz

Diode Test

Test current 1mA max., open circuit voltage
of 1.5V typical

Continuity Check

Audible signal if the resistance is < 60

Display

4000 count 3 ¾ digit LCD

Over range indication

LCD displays “OL”

Polarity

Minus (-) sign for negative polarity.

Low Battery Indication

“BAT” symbol indicates low battery
condition.

Battery

CR2032 3V Lithium

Operating Temperature

0

o

C to 40

o

C (32

o

F to 104

o

F)

Storage Temperature

-10

o

C to 50

o

C (14

o

F to 122

o

F)

Weight

50g (1.7oz)

Size

108x56x11.5mm (4.25x2.2x.5”)

Standard

IEC1010 CAT II 600V Pollution degree II,
CE Approved

Reviews: