background image

 

Description 

The C20 series handheld thermometers represent a leap 
forward in case design and specification combining a number 
of innovative features with an advanced performance. 
 
C20 series thermometers all have a high strength, 
polycarbonate case with rubber over moulding. This offers a 
very high level of strength, durability and protection against 
dust and water ingress. The C20 range is certified to meet 
IP67. All models incorporate a clock, countdown timer and 
data hold feature. For the full range of features please refer to 
Appendix 1, Page 7. 

Overview of Display Symbols 

 

HOLD SET

MENU

°C
°F

PSTK

BAT

¥

A

B

C

D

E

F

G

H

I

J

 

 

A – Indicates that HOLD has been selected. 
B – Setting menu item to ON/OFF 
C – Indicates Low Battery. 
D – The Set Up menu is active. 
E – Indicates probe type. 
F – Main Display for Temperature 
G – Clock Indicator. 
H – Display for time and countdown timer. 
I – Indicates countdown active. 
J – Alarm indication 
 
 
 

Connecting Probes to the Thermometers 

C20 series thermometers have either sub-miniature or 
Lumberg sockets for probe connection and offer a class 
leading choice between Comark thermistor, type T 
thermocouple or type K thermocouple probes. 
 
The polarity of the connector must always be checked before 
connecting thermocouple probes to C20 series thermometers. 
A probe of the correct thermocouple type must also be 
selected to match the specific thermometer. C20 series 
thermometers with Lumberg sockets will automatically detect 
the sensor type of the probe connected. The LCD will then 
indicate thermistor probes as “PST”, and type T thermocouple 
probes as “T”. Models with Sub-Min connector are of fixed 
thermocouple type, see specifications for details. 

Switching On and Off  

Display Test/Mode 

The ‘ON/OFF’ button on the keypad is used to switch on the 
thermometer. After a short pause the display will show the 
current model of the instrument and will then revert to normal 
temperature display. The current time is also permanently 
displayed on the LCD. 
 

Data Hold 

All C20 series thermometers have a data hold facility. If the ‘II’ 
button is pressed at any time during normal temperature 
mode, the current temperature will be held on the display. To 
release press ‘II’. 

Countdown Timer 

All C20 series thermometers have a countdown timer. This 
function is activated from the Set Up Menu – see section 
below, and can be calibrated in seconds/minutes or hours. 
Pressing the countdown timer button will start this function. 
Pressing the button again during the countdown period will 
stop the count. The instrument will beep for 30 seconds at the 
end of a countdown period to indicate to the user that it has 
been completed

 
 
 
 

2

 

 

 

 

 
 
 

Comark C20 Series Handheld 

Thermometers 

 

Models C21, C22, C26 and C28 

 

Operator Manual

 

 
 

 

 
 
 
 
 

 

 
 
 
 

 

Auto Switch Off/Power Saving Mode 

C20 series thermometers have a selectable auto-switch off 
feature. This is set to 3 minutes from the factory. Please refer 
to Set Up Menu for instructions on changing this setting

.  

Set Up Menu 

C20 series thermometers have a hidden menu structure that 
is used to set up a number of parameters within the 
instrument. See Appendix 1 on Page 7 – C20 Series Model 
Range Options, to see which options are available on each 
model. 
 
The set up menu can be entered when the instrument is 
switched on.  
 
To enter the set up menu first ensure the instrument is off, 
then press the Count Down button and keep this held down 
while pressing the On button to switch the instrument on. 
After the thermometer has completed its self-checks, it will 
enter the menu. 
 
N.B. After each menu item use the ON/OFF button to save  
        and move to the next menu item. 
 
Clock selection is the first item in the menu:

 

Clock – the display will show ‘CLOC’ 

Use the countdown timer button and the hold button to adjust 
the clock time up or down.  

Countdown Timer – the display will show ‘Cd’ 

Use the countdown timer button and the hold button to select 
timer on or off. Use the Hold and Countdown timer buttons to 
scroll up and down in seconds up to 5 minutes then in 1 
minute intervals up to 24 Hours.  

Scale – the display will show ‘SCAL’ 

After entering the SCALE menu, use the Countdown Timer 
button and the Hold button to scroll between the available 
scales.  
 

High Alarm – the display will show ‘HIAL’ 

 
Use the countdown timer and hold buttons to select or de-
select high alarms, then select the required high alarm value. 

                                                              

 