background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

 

FOREST SHUTTLE® S / L / M 

RECEIVER

 

Summary of Contents for SHUTTLE L

Page 1: ...2 FOREST SHUTTLE S L M RECEIVER ...

Page 2: ... PEN 1st 2nd 3rd LED PRESSED FOR 5 SEC STARTS BLINKING PRESS OPEN 3x 1x 5sec Re adjusting the open and close end position The OPEN and CLOSE end positions are a ready set to the curtain track Adding extra carriers is taken into account When the end positions need to be changed take next steps MOVE THE CURTAIN TO THE OPEN POSITION PRESS BUTTON 4x LED MOVES FROM KEEP BUTTON YELLOW LED BLINKS WITH A ...

Page 3: ...d positions have been set position the master carrier s into half open position Attach the motor to the track make sure to secure the locking pin into the motor pulley fix adaptor onto Shuttle or wall Shuttle L Shuttle S M Receiver Connect the AC plug 100 240V Connect the 24V plug into the socket of to the power socket of Shuttle L the Shuttle S M Rec and connect the AC plug to the wall socket loo...

Page 4: ...avel automatically towards the closed position SETTING OPEN LIMIT When the closed position is reached that end limit is set Pull the master carrier s to the open position The master carrier s will travel automatically towards the open position Stack back When the master carrier reaches the fully open position it will stop yellow LED4 is on Now the open limit setting can be adjusted by hand by remo...

Page 5: ...ss and hold once more for 4 seconds until the led blinks 3 times and goes OFF When a Forest remote is programmed to the Shuttle the end limits can also be reset by pressing 5 times the P button and 5 times the STOP button on the remote End limits of all Shuttles in range on this channel will reset end limits Dry contact inputs 5 6 7 Standard input is pulse contact To set to continuous or single sw...

Page 6: ...MMON the Shuttle will open the curtain CLOSE when pin 8 is connected to pin 3 COMMON the Shuttle will close the curtain STOP when pin 1 and 8 are connected to pin 3 COMMON the Shuttle will stop moving the curtain Different modes can be set Pulse when short contact is made the curtain will open or close fully default setting Continuous the curtain will move as long as the contact is made mostly use...

Page 7: ...d go off Now the SLAVE motor will follow the movement of the MASTER motor Only the MASTER motor can be controlled End limits can be set now and remotes can be programmed Situation 2 FSS Shuttle M Receiver 7131000000 Two Shuttle motors drive a Forest Skylight System FSS direction of rotation is opposite Installation steps install the track motors and power plug connect motor A port 1 to motor B por...

Page 8: ...ound level 40dB 40dB 40dB Ambient temperature 0 40 C 32 104 F 0 40 C 32 104 F 0 40 C 32 104 F Relative humidity 10 80 10 80 10 80 Maximum useable altitude above sea level 2000m 6561ft 2000m 6561ft 2000m 6561ft Certification Marking CE CE CE TECHNICAL SPECIFICATION POWER SUPPLY Shuttle S Shuttle M Receiver Model ZDA240150 ZF120A 2403000 Voltage input 100 240V 50 60Hz 0 8A 100 240V 50 60Hz 1 2A Volt...

Page 9: ...This includes all components of the curtain track and power supply adaptor Forest Group does not assume liability for resulting damages to property or personal injury defects labour on location service calls reinstallation or expenses involved shipping packing or returning goods if the product has been abused modified in any way or damaged by improper use or failure to observe these operating inst...