REPORT NO. :E930560

Page

1  of  31

NVLAP LAB CODE: 200097-0

-

PEP   Testing   Laboratory

12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih,
Taipei Hsien, Taiwan, R. O. C.
TEL: 886-2-26922097

  FAX: 886-2-26956236

FCC DoC TEST REPORT

According to

FCC Part 15    Subpart B 

Test    Item

Κ

Switching Power Supply

Model   No.

Κ

ISO-Pxxxy (where xxx = 250, 300, 350, 400, 450, 500

Ι

y = S, D or L),

ISO-xxxy (where xxx = 200, 230, 250, 300, 350, 400, 450, 500

Ι

y = D, 

L or blank)

Responsible
Party

Κ

CHANNEL WELL TECHNOLOGY CO., LTD

Address

3F-2, 888 Jing-Gwo Rd., Tao Yuan City, Taiwan, R. O. C.

        Test Engineer  :

STEVEN CHEN

        Test Date     :

OCT.

07,  2004

        Issued Date   :

NOV.

09,  2004

        NVLAP Signature :

       Peter Kao

                            Peter Kao / President 

Θ

The test report shall not be reproduced except in full, without the written approval of
the laboratory.

Θ

The report must not be used by the client to claim product endorsement by NVLAP or any
agency of the United States government.

Θ

This report is only for item test which described in page 5.

Θ

The testing result in this report are traceable to national and international standard.

PEP

TESTING  LABORATORY

12-3Fl,  No.  27-1,  Lane  169,  Kang-Ning  St.,  Hsi-Chih,
Taipei  Hsien,

Taiwan,  R.  O.  C.

TEL : 886-2-26922097

  FAX : 886-2-26956236

Summary of Contents for ISO-200

Page 1: ... 2 888 Jing Gwo Rd Tao Yuan City Taiwan R O C Test Engineer STEVEN CHEN Test Date OCT 07 2004 Issued Date NOV 09 2004 NVLAP Signature Peter Kao Peter Kao President ΘThe test report shall not be reproduced except in full without the written approval of the laboratory ΘThe report must not be used by the client to claim product endorsement by NVLAP or any agency of the United States government ΘThis ...

Page 2: ...SION 5 4 MODIFICATION S 8 5 TEST SOFTWARE USED 8 6 SUPPORT EQUIPMENT USED 9 7 DESCRIPTION OF CONDUCTED EMISSIONS TEST 11 8 DESCRIPTION OF RADIATED EMISSIONS TEST 12 9 CONDUCTED EMISSIONS TEST SETUP PHOTO 15 10 CONDUCTED EMISSIONS TEST DATA 16 11 RADIATED EMISSIONS TEST SETUP PHOTOS 21 12 RADIATED EMISSIONS TEST DATA 22 13 LIST OF MEASURED INSTRUMENTS 24 14 DUTIES OF THE RESPONSIBLE PARTY 25 15 LAB...

Page 3: ...D Address 3F 2 888 Jing Rd Tao Yuan City Taiwan R O C Contact Person Jacky Hsieh Engineer Phone No 886 3 3163111 Fax No 886 3 3160455 Regulation FCC Part 15 Part 2 Docket 95 19 Limitation CISPR 22 CLASS B Test Procedure ANSI C63 4 1992 Test Item Switching Power Supply Model No ISO Pxxxy ISO xxxy Serial No N A Place of Test PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei...

Page 4: ...Product Information a EUT Name Switching Power Supply b Model No Κ ISO P500D c Chassis UsedΚ Steel d Port Connector s Κ N A e Power RatingΚ Switching Power Supply Model No ISO P500D Input AC 120V 9A 60Hz 420W Output DC 3 3V 5V 12V1 12V2 12V 5Vsb 22A 32A 14A 15A 0 5A 2 0A f Condition of the EUT ϭ Prototype Sample Engineering Sample ʳ ϭ Production Sample g Test Item Receipt Date OCT 07 2004 ...

Page 5: ...ried out on EUT operational condition and the worst case test result was recorded and provided in this report Conducted emission test The system was setup with the EMI diagnostic software running The power line conducted EMI tests were run on the line and neutral conductors of the power cord and the results were recorded The effect of varying the position of the interface cables has been investiga...

Page 6: ...V Total ISO P500y y S D or L 115 230Vac 9 5A 60 50Hz 22 32 14 15 0 5 0 5 2 0 220W 420W ISO P450y y S D or L 115 230Vac 8 5A 60 50Hz 20 28 10 15 0 5 0 5 2 0 200W 350W ISO P400y y S D or L 115 230Vac 7 4A 60 50Hz 20 26 8 14 0 5 0 5 2 0 185W 300W ISO P350y y S D or L 115 230Vac 7 4A 60 50Hz 16 22 6 12 0 5 0 5 2 0 150W 250W ISO P300y y S D or L 115 230Vac 6 4A 60 50Hz 14 20 6 10 0 5 0 5 1 5 135W 235W ...

Page 7: ... 0 220W 420W ISO 450y y D L or blank 115 230Vac 8 5A 60 50Hz 20 32 16 0 5 0 5 2 0 200W 350W ISO 400y y D L or blank 115 230Vac 7 4A 60 50Hz 20 30 15 0 5 0 5 2 0 185W 300W ISO 350y y D L or blank 115 230Vac 7 4A 60 50Hz 16 25 13 0 5 0 5 1 5 150W 250W ISO 300y y D L or blank 115 230Vac 6 4A 60 50Hz 14 20 12 0 5 0 5 1 5 135W 235W ISO 250y y D L or blank 115 230Vac 5 3A 60 50Hz 14 18 10 0 5 0 3 1 5 12...

Page 8: ...tory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 4 Modification s N A 5 Test Software Used A EMITEST program that continuously generates a complete line of repeating H letter was the software used during test ...

Page 9: ...KBS1 PS 2 FCC IDΚE5XKB5121WTH0110 ManufacturerΚBTC Model NumberΚ5121W Power SupplyΚ 5Vdc from PS2 of PC Power CordΚN A Data CableΚ1 Shielded Non detachable 1 6m 2 Back Shell Metal 3 Monitor MON1 15 FCC IDΚDeclaration of Conformity DoC ManufacturerΚSAMSUNG Model NumberΚ550S Power SupplyΚSwitching Power CordΚNon Shielded Detachable 1 8m Data CableΚ1 Shielded Non detachable 1 5m 2 Back Shell Metal 4 ...

Page 10: ...56236 5 Modem MOD1 2 FCC IDΚIFAXDM1414 ManufacturerΚACEEX Model NumberΚ1414 Power SupplyΚLinear 9Vac O P Power CableΚNon Shielded Detachable 1 7m Data CableΚ1 Shielded Detachable 1m 2 Back Shell Metal 6 Mouse MOUS 1 PS 2 FCC IDΚDZL211106 ManufacturerΚACER Model NumberΚM S42 Power SupplyΚ 5Vdc from PS2 of PC Power CordΚN A Data CableΚ1 Shielded Non detachable 1 8m 2 Back Shell Metal ...

Page 11: ... operating condition The RF output of the AMN was connected to the spectrum analyzer to determine the frequency producing the maximum EME from the EUT The spectrum was scanned from 150kHz to 30 MHz with1 5 sec sweep time The frequency producing the maximum level was re examined using Quasi Peak adapter The detector function was set to CISPR quasi peak mode The bandwidth of the receiver was set to ...

Page 12: ...g logbicon antenna and horn antenna The test equipment was placed on a wooden bench situated on a 1 5x1 meter area adjacent to the measurement area Sufficient time for the EUT support equipment and test equipment was allowed in order for them to warm up to their normal operating condition Each frequency found during pre scan measurements was re examined and investigated using Quasi Peak Adapter Th...

Page 13: ...inating impedance The total length shall not exceed 1 m 3 If LISN are kept in the test setup for radiated emissions it is preferred that they be installed under the ground if requires receptacle flush with the ground plane 4 Cables of hand operated devices such as keyboards KEYPADs etc have to be placed as close as possible to the controller 5 Non EUT components of EUT system being tested 6 The re...

Page 14: ...0 m Frequency MHz Field Strength dB ӴV m 30 to 230 40 230 to 1 000 47 NOTES 1 The lower limit shall apply at the transition frequency 2 Additional provisions may be required for cases where interference occurs Limits for radiated disturbance of Class B ITE at a measuring distance of 10 m Frequency MHz Field Strength dB ӴV m 30 to 230 30 230 to 1 000 37 NOTES 1 The lower limit shall apply at the tr...

Page 15: ...Page 15 of 31 NVLAP LAB CODE 200097 0 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 9 Conducted Emissions Test Setup Photo FRONT VIEW ...

Page 16: ...pei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 10 Conducted Emissions Test Data Model No ISO P500D Frequency range 150KHz to 30MHz Detector Peak Average Value Temperature 28 к Humidity 59 Test Data 801 333 ˏ ˡ ʳˑ 806 338 ˏˡ ˑ Note 1 Level Read Level Probe LISN Factor Cable Loss 2 Over Limit Level Limit Line Margin ...

Page 17: ...Page 17 of 31 NVLAP LAB CODE 200097 0 ...

Page 18: ...Page 18 of 31 NVLAP LAB CODE 200097 0 ...

Page 19: ...Page 19 of 31 NVLAP LAB CODE 200097 0 ...

Page 20: ...Page 20 of 31 NVLAP LAB CODE 200097 0 ...

Page 21: ...1 of 31 NVLAP LAB CODE 200097 0 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 11 Radiated Emissions Test Setup Photos FRONT VIEW REAR VIEW ...

Page 22: ...mit Read Antenna Cable Preamp Freq Level Limit Line Level Factor Loss Factor Azimuth Antenna MHz dBuV m dB dBuV m dBuV dB dB dB angle High m 48 156 17 81 12 19 30 00 25 82 10 83 0 72 19 56 176 0 4 0 66 546 19 41 10 59 30 00 29 79 8 15 0 87 19 40 193 0 4 0 147 289 19 79 10 21 30 00 21 86 16 11 1 24 19 42 154 0 4 0 166 222 16 75 13 25 30 00 19 18 15 61 1 34 19 38 24 0 4 0 200 553 19 97 10 03 30 00 2...

Page 23: ... Cable Preamp Freq Level Limit Line Level Factor Loss Factor Azimuth Antenna MHz dBuV m dB dBuV m dBuV dB dB dB angle High m 31 533 18 50 11 50 30 00 26 80 10 63 0 53 19 46 177 0 1 0 47 975 20 61 9 39 30 00 28 62 10 84 0 71 19 56 148 0 1 0 66 478 18 94 11 06 30 00 29 24 8 22 0 86 19 38 197 0 1 0 144 160 18 23 11 77 30 00 20 79 15 60 1 18 19 34 183 0 1 0 170 561 17 87 12 13 30 00 20 94 14 86 1 37 1...

Page 24: ...S LISN EUT ESH2 Z5 831886 004 Apr 06 2005 1Year Kyoritsu LISN 2nd KNW 242 8 837 7 N A N A Conduction No 2 RF Cable No 4 N A Feb 19 2005 1Year R S Receiver ESBI 845658 003 Sep 07 2005 1Year Schaffner Pre Amp CPA 9232 1012 Aug 21 2005 1Year SCHWARZBECK Antenna 9161 9161 4051 May 06 2005 1Year COM Power Horn Ant AH 118 1GHz 18GHz 10095 May 21 2005 1Year RF Cable No 2 N A Feb 19 2005 1Year SCHWARZBECK...

Page 25: ...tics of the equipment 2 1073 e If any modifications or changes made by anyone other than the responsible party the party making the modifications of changes if located within the U S becomes the new responsible part The new responsible party must comply with all provisions for the DoC including having test data on file demonstrating that the product continues to comply with all of the applicable t...

Page 26: ...own below shall be permanently affixed at a conspicuous location on the device instructions manual or pamphlet supplied to the user and be readily visible to the purchaser at the time of purchase However when the device is so small wherein placement of the label with specified statement is not practicable only the trade name model number and the FCC logo must be displayed on the device per Section...

Page 27: ...t harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or tel...

Page 28: ...30560 Page 28 of 31 NVLAP LAB CODE 200097 0 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 17 EUT Photographs Model No ISO P500D ...

Page 29: ...REPORT NO E930560 Page 29 of 31 NVLAP LAB CODE 200097 0 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 ...

Page 30: ...REPORT NO E930560 Page 30 of 31 NVLAP LAB CODE 200097 0 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 ...

Page 31: ...REPORT NO E930560 Page 31 of 31 NVLAP LAB CODE 200097 0 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 ...

Page 32: ... CISPR 22 CLASS B Date of issued NOV 09 2004 Report No E930560 The device bearing the trade name and model specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63 4 1992 See Test Report if any modifications were made for compliance PEP certifies that no...

Page 33: ...h Engineer Phone No 886 3 3163111 Fax No 886 3 3160455 Equipment Switching Power Supply Model No ISO Pxxxy xxx 250 300 350 400 450 500Ιy S D or L ISO xxxy xxx 200 230 250 300 350 400 450 500Ιy D L or blank We hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable FCC Rules under the most accurate measurement standards possi...