Handheld Programmer
Operating Instructions
Step1. Basic Operation
To turn on the programmer, lift the rubber flat on the
base, this will expose the switch and USB connec-
tion, move the switch to the ON position, the unit will
now power up. Re-fit the rubber flap (see Programmer
layout). Once powered on, the clock and date must be
initially set.
Use the up and down Navigation Buttons (
) to high-
light the MENU TITLE (shown in red) Use left and right
Navigation Buttons (
) to select desired menu.
Use the up and down Navigation Buttons (
) to choose
the parameter you wish to change, such as Sensor
Range. Then use the left and right Navigation Buttons
(< and >) to change the parameter within the option.
MENU OPTION CHOICES:
Medi-flo Sink Menu
: To modify parameters for Medi-flo and Ozo-flo
Ozone Control Menu
: To reset datalogging parameters for Medi-flo and Ozo-flo
System Menu
: General settings for the programmer
Setup Clock
: Set the date and time
Tap Menu:
To modify parameters for hands free taps
To adjust sensor settings, point the Infra-red port at 90° to the sensor at a distance of no
more than 30 cm (1 foot), and press the recieve button (see
Programmer Layout
). When the
sensor is read a confirmation tick will appear on the screen. The correct menu for the sensor
will then be displayed and settings can be adjusted accordingly. To send new settings to the
sensor, point the IR port at the sensor as above, then press and hold the send button until the
green tick appears. Sensor is now set with the new settings.
IMPORTANT: Once you program the sensor, leave for a minimum of 30 seconds before
attempting to use. This allows the sensor to recalibrate. Attempting to use before this time
may cause the sensor to lock up or false trigger.
SCREEN LEGEND (Medi-flo Menu)
TDS = Water Conductivity (estimated total dissolved solids)
V = Number of actuations the solenoid valve has made
O = Total time in hours the ozone generator has run.
AC01-005
2030040792 |
01/19
2
Step 2. Data Logging
a) To upload data from the programmer, ensure it is switched ON, then connect the pro-
grammer to your computer via USB.
b) When prompted, press ‘OK’ on programmer keypad to enter mass storage mode.
c) Find USB drive in ‘My Computer’ area.
d) Navigate through the data folders to find Excel DSV files for relevant product readings.
Step 3. Charging
The programmer requires a universal USB charging device. If being charged by computer,
connect the USB cable to the programmer and then to the computer. The programmer will
then display a menu giving an option to ‘
download
’ or ‘
charge
’. Follow prompts to ‘
press
any button
’ to begin charging and display ‘
charging
’ on screen. Allow to trickle charge for
a minimum of 8 hours.
Menu Options Explained
1. Medi-flo Sink Menu
Sensor Range – (2 to 10) Default: 5
The distance away from the sensor that will trigger operation.
Anti-Vandal Time (30s, 1 min, 2 min) Default: 30 Seconds
In the event of a blocked or vandalized sensor, this is the time that the sink will run until
automatically shutting off.
Post Wash Cycle Timer (10, 15, 20, 25, 30s) Default: 30 Seconds
This is the time between last activation and the 3 seconds post-wash run time. This can
be used as a signal that a user has lathered for a desired period of time.
Purge Cycle Frequency (Off, Always, 3, 6, 12, 24, 48 hrs) Default: Always
The purge cycle is when the ozone generator runs without water flow. If set to always,
the purge cycle will run (per the setting of Ozone Run Time below) and the water will be
left in the chamber available for the next hand wash cycle. This setting yields the best
result for hand hygiene. If it is set to any other setting, at the conclusion of the purge
cycle, the sink will automatically come on for 9 seconds to empty the chamber into the
waste to help with disinfection.
Ozone Run Time (Auto, 1, 3, 5, 10, 15, 30, 45) Default: Auto
This is the length of time in minutes that the purge cycle will run the ozone generator.
If set to auto, the time will be based upon the water conductivity reading (TDS) which
is measured by the system. To generate ample amounts of mixed oxidants, the ozone
generator has to run longer in lower conductivity water.
Max Bright LED (0 – 100%) Default: 51%