background image

IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make repairs
due to the possibility of electrical
shock. Disconnect power cord
before servicing.

216908200
SERVICE DATA SHEET
CHEST FREEZER

INSTALLATION
This product is designed for “free standing installation only” and three
inches of clearance must be provided on all sides of the freezer for air
circulation.

The floor or mounting surface should be level and capable of supporting the
weight of the freezer when it is fully loaded.

REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.

TEMPERATURE CONTROL
16.0°F cut in, 0°F cut-out @ number 1 setting.

PERFORMANCE (Control at number 1 setting)

Room Ambient

70°F

90°F

Freezer Compartment Temperature

5 to 12°F

5 to 12°F

Percent Running Time

30-40%

40-50%

*Wattage Range (Last 

1

of cycle)

85-100

95-110

Suction Pressure (Cut-in, cut-out), PSIG

15-0

15-0

High Side Pressure (Last 

1

3

of cycle), PSIG

95-110

140-155

Specifications subject to change without notice.
*For complete performance data by model refer to service manual.

PD641

IMPORTANT

If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.

Yel

See Diagram

Blk

Wh

Compressor

Temp Warning

Buzzer

Red

Cold Control

Alarm Sensor

Alarm

Off

On

Red

Door

Switch

Interior

Light

Power On

ELECTRICAL CIRCUIT

Red

N

L

Power

EC69

Overload

C

Yel

S

Wh

R

Relay

SYSTEM SCHEMATIC

Condenser

High Side

Process Tube

Drier

Capillary

Evaporator

Suction

Tube

Compressor

Low Side Process Tube

Discharge

SS1

WIRING DIAGRAM

C09