background image

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

(For 3 or 4 Wire, 60 Hz. Systems)

1

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

p/n  316454901 (0509) EN

Clearances and Dimensions

1.

Provide adequate clearances between the range and adjacent combustible surfaces.

2.

Location—Check location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.

3.

Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.

*30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE  BOTTOM OF AN UNPROTECTED WOOD OR
METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" FLAME
RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" STAINLESS STEEL, 0.024" ALUMINUM OR
0.020" COPPER. 0" CLEARANCE IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED
ABOVE TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.

TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED
ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY
INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.

Español - Páginas 5-8

IMPORTANT SAFETY INSTRUCTIONS

 If the information in this manual is not followed exactly, a fire or

electrical shock may result causing property damage, personal injury or death.

Important Notes to the Installer

Read all instructions contained in these installation instructions before
installing range.

Remove all packing material from the oven compartments before connecting
the gas & electrical supply to the range.

Observe all governing codes and ordinances.

Be sure to leave these instructions with the consumer.

Important Note to the Consumer
Keep these instructions with your owner's guide for future reference.

As when using any appliance generating heat, there are certain safety precautions you should follow. These are listed in
the Use & Care Manual, read it carefully.

Be sure your range is installed and grounded properly by a qualified installer or service technician.

Make sure the wall coverings around the range can withstand the heat generated by the range.

To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided.

Fig. 1

Fig. 2

Fig. 3

30"

Summary of Contents for FEFS66DSJ

Page 1: ... FIRE BY REACHING OVER HEATED SURFACE UNITS CABINET STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED IF CABINET STORAGE IS TO BE PROVIDED THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS Español Páginas 5 8 IMPORTANT SAFETY INSTRUCTIONS If the information in this manual is not followed exactly a fire or el...

Page 2: ...if installing in concrete For electrical supply connection 1 4 3 8 Socket driver or Nutdriver Additional Materials You Will Need Power Supply Cord or Copper Electrical Wiring Metal Conduit for hard wiring to the wall drill pilot hole at an approximate 20 downward angle See Fig 5 If bracket is to be mounted to masonry or ceramic floors drill a 5 32 pilot hole 1 3 4 deep The screws provided may be u...

Page 3: ...E The Rear Access Cover must be removed Fig 9 To remove loosen center screw one screw and remove cover The terminal block will then be accessible Fig 10 4A POWER CORD CONNECTIONS Fig 11 Fig 12 4 Wire Connection Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile hom...

Page 4: ...tem new branch circuit or mobile home requires 4 Wire connection 1 3 4 Wire Permanent Connections Follow the manufacturer s installation instructions supplied with the strain relief and install 2 3 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal b...

Reviews: