IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make
repairs due to the possibility of
electrical shock. Disconnect
power cord before servicing.
216803100
SERVICE DATA SHEET
MANUAL DEFROST
UPRIGHT FREEZER
INSTALLATION
This product is designed for “free standing installation only” and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
11.1°F cut in, -4.7°F cut-out @ number 1 setting.
PERFORMANCE (Control at number 1 setting)
Room Ambient
70°F
90°F
Freezer Compartment Temperature
5 to 10°F
5 to 10°F
Percent Running Time
40-55%
45-60%
*Wattage Range (Last
1
⁄
3
of cycle)
70-110
70-110
Suction Pressure (Cut-in, cut-out), PSIG
15-0
15-0
High Side Pressure (Last
1
⁄
3
of cycle), PSIG
105-115
140-160
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
PD643
IMPORTANT
If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.
ELECTRICAL CIRCUIT
Power
Blk
Wh
Blu
Compressor
See Diagram
Pink
Temp Warning
Cold
Control
Alarm
Off
On
Red
Buzzer
Red
Door
Switch
Interior
Light
Power On
EC40
Run
Capacitor
Compressor
Controller
Blu
Wh
C26
SYSTEM SCHEMATIC
Condenser
High Side
Process Tube
Drier
Capillary
Evaporator
Suction
Tube
Compressor
Low Side Process Tube
Discharge
SS1
WIRING DIAGRAM