background image

IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make
repairs due to the possibility of
electrical shock. Disconnect
power cord before servicing.

216803100
SERVICE DATA SHEET
MANUAL DEFROST
UPRIGHT FREEZER

INSTALLATION
This product is designed for “free standing installation only” and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.

REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.

TEMPERATURE CONTROL
11.1°F cut in, -4.7°F cut-out @ number 1 setting.

PERFORMANCE (Control at number 1 setting)

Room Ambient

70°F

90°F

Freezer Compartment Temperature

5 to 10°F

5 to 10°F

Percent Running Time

40-55%

45-60%

*Wattage Range (Last 

1

of cycle)

70-110

70-110

Suction Pressure (Cut-in, cut-out), PSIG

15-0

15-0

High Side Pressure (Last 

1

3

of cycle), PSIG

105-115

140-160

Specifications subject to change without notice.
*For complete performance data by model refer to service manual.

PD643

IMPORTANT

If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.

ELECTRICAL CIRCUIT

Power

Blk

Wh

Blu

Compressor

See Diagram

Pink

Temp Warning

Cold

Control

Alarm

Off

On

Red

Buzzer

Red

Door

Switch

Interior

Light

Power On

EC40

Run

Capacitor

Compressor

Controller

Blu

Wh

C26

SYSTEM SCHEMATIC

Condenser

High Side

Process Tube

Drier

Capillary

Evaporator

Suction

Tube

Compressor

Low Side Process Tube

Discharge

SS1

WIRING DIAGRAM