216803200
SERVICE DATA SHEET
MANUAL DEFROST
UPRIGHT FREEZER
INSTALLATION
This product is designed for “free standing installation only” and three inches
of clearance must be provided on all sides of the freezer for air circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
8.5°F cut in, -3.5°F cut-out @ number 1 setting.
PERFORMANCE (Control at number 1 setting)
Room Ambient
70°F
90°F
Freezer Compartment Temperature
2 to 8°F
2 to 8°F
Percent Running Time
30-40%
45-60%
*Wattage Range (Last
1
⁄
3
of cycle)
105-120
110-125
Suction Pressure (Cut-in, cut-out), PSIG
14-0
14-0
High Side Pressure (Last
1
⁄
3
of cycle), PSIG
110-125
155-170
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
PD644
IMPORTANT
If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.
ELECTRICAL CIRCUIT
Power
Blk
Wh
Blu
Compressor
See Diagram
Pink
Temp Warning
Cold
Control
Alarm
Off
On
Red
Buzzer
Red
Door
Switch
Interior
Light
Power On
EC40
Run
Capacitor
Compressor
Controller
Blu
Wh
C26
SYSTEM SCHEMATIC
Condenser
High Side
Process Tube
Drier
Capillary
Evaporator
Suction
Tube
Compressor
Low Side Process Tube
Discharge
SS1