Summary of Contents for FGGF301DNBA

Page 1: ... appliance installed in the State of Massachusetts see page 2 Front view 49 Maximum A_ 36 1 8 30 minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or 24 minimum when bottom of wood or metal cabinet is protected by not less than 1 4 flame retardant millboard covered with not less than no 28 NSG sheet steel 0 015 stainless steel 0 024 alu...

Page 2: ...ions Before installing the range in an area covered with linoleum or any other synthetic floor covering make sure the floor covering can withstand heat at least 90 F above room temperature without shrinking warping or discoloring Do not install the range over carpeting unless you place an insulating pad or sheet of 1 4 10 16cm thick plywood between the range and carpeting Make sure the wall coveri...

Page 3: ...this appliance DO NOT MAKE ANY ATTEMPT TO OPERATE THE ELECTRIC IGNITION OVEN DURING AN ELECTRICAL POWER FAILURE RESET ALL OVEN CONTROLS TO OFF IN THE EVENT OF A POWER FAILURE The electric ignitor will automatically re ignite the oven burner when power resumes if the oven thermostat control was left in the ON position When an electrical power failure occurs during use the surface burners will conti...

Page 4: ...d If bracket is to be mounted to the wall drill pilot hole at an approximate 20 downward angle If bracket is to be mounted to masonry or ceramic floors drill a 3 16 pilot hole 1 3 4 deep The screws provided may be used in wood or concrete material Use a 5 16 nut driver or fiat head screwdriver to secure the bracket in place FASTEN BRACKET WALL ORFLOOR MOUNTING _1 1_ 1 1 4 Max Leveling leg Instruct...

Page 5: ...igure 4 Provide an adequate Gas Supply When shipped from the factory this unit is designed to operate on 4 10 16cm water column 1 0 kPa Natural gas manifold pressure A convertible pressure regulator is connected to the range manifold and MUST be connected in series with the gas supply line If LP Propane conversion kit has been used follow instructions provided with the kit for converting the press...

Page 6: ... as shown on figure 5c This will prevent the flexible connector from pinching or blocking the unit when you will push it back in its final position H Check for leaks Turn the gas supply on to the range and use a liquid leak detector or soap and water at all joints and conduits to check for leaks in the system Figure 5c Note The purpose of forming the gas flexible connector is to position it in a w...

Page 7: ...is cooktop is equipped with sealed burners All pieces are at their place Take note where they are Remove all packaging material Make sure the burner caps are properly aligned and leveled The burner cap lip See Figure 7 should fit snug into the center of burner head and rest level Refer to Figures 8 9 for correct and incorrect burner cap placement Once in place you may check the fit by gently slidi...

Page 8: ...thout going out Note Air mixture adjustment is not required on surface burners Operation of Oven Burners and Oven Adjustments Electric Ignition Burners Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power The oven burner is equipped with an electric control system as well as elec...

Page 9: ...ry for cleaning or maintenance shut off gas supply Disconnect the gas and electrical supply If gas or electrical supply is inaccessible lift the unit slightly at the front and pull out away from the wall Pull only as far as necessary to disconnect the gas and electrical supply Finish moving the unit for servicing and cleaning Reinstall in reverse order making sure to level the range and check gas ...

Page 10: ...Notes 10 ...

Page 11: ...OTOR BE CBRROJO BK 14 _ J OPCION BK 14 BK_2O BK 20 BK 14 J __ TEMPERATURE PROBE LWR OV i BK 14 UPR OV IIIIIIIIIIIIII IIIIIIIIIIIII lllll i I TE PERATORE P O E P_o _ _ OTO_ BO_O BK14 _ _ BK _4 I __o__ BK 14 BK 20 _ BK20 BK 14 I W 6 EOC RELAY BOARD PANEL DE RELEVADORES DEL HORNO UPR OV IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIII J3 W_14 I OPTION i OPCION R 14 IArC_ _00_ _OTO_ _ ...

Page 12: ... BEFORE SERVICING UNIT LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRINGS ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATENCION CORTAR LA CORRIENTE ANTES DE REALIZAR EL MANTENIMIENTO DEL ELECTRODOMESTICO ETIQUETE TODOS LOS CABLES ANTES DE DESCONECTAR CUANDO HAGA EL SERVIBIO A LOS CONTROLES ERRORES AL VOLVER A ENSAMBLAR LOS CABLES PUE...